Respiratory correlated cone-beam computed tomography on an isocentric C-arm

被引:49
|
作者
Kriminski, S [1 ]
Mitschke, M
Sorensen, S
Wink, NM
Chow, PE
Tenn, S
Solberg, TD
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[2] Siemens Med Solut USA Inc, Oncol Care Syst, Concord, CA 94520 USA
[3] Jonsson Comprehens Canc Ctr, Los Angeles, CA 90095 USA
[4] Univ Nebraska Med Ctr, Omaha, NE 68102 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 22期
关键词
D O I
10.1088/0031-9155/50/22/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A methodology for 3D image reconstruction from retrospectively gated cone-beam CT projection data has been developed. A mobile x-ray cone-beam device consisting of an isocentric C-arm equipped with a flat panel detector was used to image a moving phantom. Frames for reconstruction were retrospectively selected from complete datasets based on the known rotation of the C-arm and a signal from a respiratory monitor. Different sizes of gating windows were tested. A numerical criterion for blur on the reconstructed image was suggested. The criterion is based on minimization of an Ising energy function, similar to approaches used in image segmentation or restoration. It is shown that this criterion can be used for the determination of the optimal gating window size. Images reconstructed from the retrospectively gated projection sequences using the optimal gating window data showed a significant improvement compared to images reconstructed from the complete projection datasets.
引用
下载
收藏
页码:5263 / 5280
页数:18
相关论文
共 50 条
  • [1] Use of robotic C-arm cone-beam computed tomography in surgical stabilization of rib fractures
    Yen, Ming-Hong
    Liu, Tsu-Hao
    Liu, Jung -Sen
    Yim, Shelly
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (12):
  • [2] C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Chiara Floridi
    Alessandro Radaelli
    Nadine Abi-Jaoudeh
    Micheal Grass
    Ming De Lin
    Melanie Chiaradia
    Jean-Francois Geschwind
    Hishman Kobeiter
    Ettore Squillaci
    Geert Maleux
    Andrea Giovagnoni
    Luca Brunese
    Bradford Wood
    Gianpaolo Carrafiello
    Antonio Rotondo
    La radiologia medica, 2014, 119 : 521 - 532
  • [3] Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endo grafting
    Dijkstra, Martijn L.
    Eagleton, Matthew J.
    Greenberg, Roy K.
    Mastracci, Tara
    Hernandez, Adrian
    JOURNAL OF VASCULAR SURGERY, 2011, 53 (03) : 583 - 590
  • [4] C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Floridi, Chiara
    Radaelli, Alessandro
    Abi-Jaoudeh, Nadine
    Grass, Micheal
    De Lin, Ming
    Chiaradia, Melanie
    Geschwind, Jean-Francois
    Kobeiter, Hishman
    Squillaci, Ettore
    Maleux, Geert
    Giovagnoni, Andrea
    Brunese, Luca
    Wood, Bradford
    Carrafiello, Gianpaolo
    Rotondo, Antonio
    RADIOLOGIA MEDICA, 2014, 119 (07): : 521 - 532
  • [5] Survival Impact of C-Arm Cone-Beam Computed Tomography on Hepatocellular Carcinoma Patients Undergoing Chemoembolization
    Wallace, Michael J.
    Abdelsalam, Mohamed E.
    Ensor, Joseph E.
    Kaseb, Ahmed O.
    Tam, Alda
    Avritscher, Rony
    Gupta, Sanjay
    HEPATOLOGY, 2012, 56 : 466A - 467A
  • [6] C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    Chiara Floridi
    Alessandra Muollo
    Federico Fontana
    Nicola Rotolo
    Anna Maria Ierardi
    Ejona Duka
    Carlo Pellegrino
    Gianpaolo Carrafiello
    La radiologia medica, 2014, 119 : 820 - 827
  • [7] C-arm cone-beam computed tomography needle path overlay for percutaneous biopsy of pulmonary nodules
    Floridi, Chiara
    Muollo, Alessandra
    Fontana, Federico
    Rotolo, Nicola
    Ierardi, Anna Maria
    Duka, Ejona
    Pellegrino, Carlo
    Carrafiello, Gianpaolo
    RADIOLOGIA MEDICA, 2014, 119 (11): : 820 - 827
  • [8] Erratum to: C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications
    Chiara Floridi
    Alessandro Radaelli
    Nadine Abi-Jaoudeh
    Michael Grass
    MingDe Lin
    Melanie Chiaradia
    Jean-Francois Geschwind
    Hicham Kobeiter
    Ettore Squillaci
    Geert Maleux
    Andrea Giovagnoni
    Luca Brunese
    Bradford Wood
    Gianpaolo Carrafiello
    Antonio Rotondo
    La radiologia medica, 2015, 120 : 406 - 406
  • [9] Dual-rotation C-arm cone-beam computed tomography to increase low-contrast detection
    Reshef, Aymeric
    Riddell, Cyril
    Trousset, Yves
    Ladjal, Said
    Bloch, Isabelle
    MEDICAL PHYSICS, 2017, 44 (09) : E164 - E173
  • [10] Intraoperative C-arm cone-beam computed tomography: Quantitative analysis of surgical performance in skull base surgery
    Lee, Stella
    Gallia, Gary L.
    Reh, Douglas D.
    Schafer, Sebastian
    Uneri, Ali
    Mirota, Daniel J.
    Nithiananthan, Sajendra
    Otake, Yoshito
    Stayman, J. Webster
    Zbijewski, Wojciech
    Siewerdsen, Jeffrey H.
    LARYNGOSCOPE, 2012, 122 (09): : 1925 - 1932