Respiratory correlated cone-beam computed tomography on an isocentric C-arm

被引:49
|
作者
Kriminski, S [1 ]
Mitschke, M
Sorensen, S
Wink, NM
Chow, PE
Tenn, S
Solberg, TD
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Dept Radiat Oncol, Los Angeles, CA 90024 USA
[2] Siemens Med Solut USA Inc, Oncol Care Syst, Concord, CA 94520 USA
[3] Jonsson Comprehens Canc Ctr, Los Angeles, CA 90095 USA
[4] Univ Nebraska Med Ctr, Omaha, NE 68102 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 22期
关键词
D O I
10.1088/0031-9155/50/22/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A methodology for 3D image reconstruction from retrospectively gated cone-beam CT projection data has been developed. A mobile x-ray cone-beam device consisting of an isocentric C-arm equipped with a flat panel detector was used to image a moving phantom. Frames for reconstruction were retrospectively selected from complete datasets based on the known rotation of the C-arm and a signal from a respiratory monitor. Different sizes of gating windows were tested. A numerical criterion for blur on the reconstructed image was suggested. The criterion is based on minimization of an Ising energy function, similar to approaches used in image segmentation or restoration. It is shown that this criterion can be used for the determination of the optimal gating window size. Images reconstructed from the retrospectively gated projection sequences using the optimal gating window data showed a significant improvement compared to images reconstructed from the complete projection datasets.
引用
收藏
页码:5263 / 5280
页数:18
相关论文
共 50 条
  • [31] Dose and detectability for a cone-beam C-arm CT system revisited
    Ganguly, Arundhuti
    Yoon, Sungwon
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2010, 37 (05) : 2264 - 2268
  • [32] Dose and image quality for a cone-beam C-arm CT system
    Fahrig, Rebecca
    Dixon, Robert
    Payne, Thomas
    Morin, Richard L.
    Ganguly, Arundhuti
    Strobel, Norbert
    MEDICAL PHYSICS, 2006, 33 (12) : 4541 - 4550
  • [33] Localizing spherical fiducials in C-arm based cone-beam CT
    Yaniv, Ziv
    MEDICAL PHYSICS, 2009, 36 (11) : 4957 - 4966
  • [34] Hardware-accelerated cone-beam reconstruction on a mobile C-arm
    Churchill, Michael
    Medical Imaging 2007: Physics of Medical Imaging, Pts 1-3, 2007, 6510 : U2193 - U2200
  • [35] Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    Daly, M. J.
    Siewerdsen, J. H.
    Cho, Y. B.
    Jaffray, D. A.
    Irish, J. C.
    MEDICAL PHYSICS, 2008, 35 (05) : 2124 - 2136
  • [36] Combined C-Arm Fluoroscopy and C-Arm Cone Beam Computed Tomography for the Evaluation of Patients With Possible Intrathecal Baclofen Delivery System Malfunctions
    Schapiro, Andrew
    Racadio, John
    Kinnett, Douglas
    Maugans, Todd
    NEUROSURGERY, 2011, 69 : 27 - 33
  • [38] Effect of metal artifact reduction software on image quality of C-arm cone-beam computed tomography during intracranial aneurysm treatment
    Enomoto, Yukiko
    Yamauchi, Keita
    Asano, Takahiko
    Otani, Katharina
    Iwama, Toru
    INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (03) : 303 - 308
  • [39] C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications (vol 119, pg 521, 2014)
    Floridi, Chiara
    Radaelli, Alessandro
    Abi-Jaoudeh, Nadine
    Grass, Michael
    Lin, MingDe
    Chiaradia, Melanie
    Geschwind, Jean-Francois
    Kobeiter, Hicham
    Squillaci, Ettore
    Maleux, Geert
    Giovagnoni, Andrea
    Brunese, Luca
    Wood, Bradford
    Carrafiello, Gianpaolo
    Rotondo, Antonio
    RADIOLOGIA MEDICA, 2015, 120 (04): : 406 - 406
  • [40] Learning Curve of C-Arm Cone-beam Computed Tomography Virtual. Navigation-Guided Percutaneous Transthoracic Needle Biopsy
    Ahn, Su Yeon
    Park, Chang Min
    Yoon, Soon Ho
    Kim, Hyungjin
    Goo, Jin Mo
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (05) : 844 - 853