Novel Clinically Weight-Optimized Dynamic Conformal Arcs (WO-DC A) for Liver SBRT: A Comparison with Volumetric Modulated Arc Therapy (VMAT)

被引:1
|
作者
Saglann, Yucel [1 ,2 ]
Bolukbasi, Yasemin [1 ,2 ,3 ]
Atasoy, Ali Ihsan [1 ]
Karakose, Fatih [1 ]
Budak, Mustafa [1 ]
Alpan, Vildan [1 ,2 ]
Topkan, Erkan [4 ]
Selek, Ugur [1 ,2 ,3 ]
机构
[1] Koc Univ, Sch Med, Dept Radiat Oncol, Davutpasa Caddesi 4, TR-34010 Istanbul, Turkey
[2] Amer Hosp, UT MD Anderson Radiat Oncol Outreach Ctr, Istanbul, Turkey
[3] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
[4] Baskent Univ, Med Fac, Dept Radiat Oncol, Adana, Turkey
关键词
liver; stereotactic body radiotherapy; dynamic conformal arcs; weight optimization; VMAT; BODY RADIATION-THERAPY; MOTION MANAGEMENT; DOSE PRESCRIPTION; RADIOTHERAPY; METASTASES; INTERPLAY; DELIVERY; ORGAN; RISK;
D O I
10.2147/TCRM.S328375
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Purpose: To evaluate the feasibility of shortening the duration of liver stereotactic radiotherapy (SBRT) without jeopardizing dosimetry or conformity by utilizing weight-optimized dynamic conformal arcs (WO-DCA) as opposed to volumetric modulated arc therapy (VMAT) for tumors away from critical structures. Methods: Nineteen patients with liver metastasis were included, previously treated with 50 Gy in 4 fractions with VMAT technique using two partial coplanar arcs of 6 MV beams delivered in high-definition multi-leaf collimator (HD-MLC). Two coplanar partial WODCA were generated on Pinnacle treatment planning system (TPS) for each patient; and MLC aperture around the planning target volume (PTV) was automatically generated at different margins for both arcs and maintained dynamically around the target during arc rotation. Weight of the two arcs using optimization method was adjusted between the arcs to maximize tumor coverage and protect organs at risk (OAR) based on the RTOG-0438 protocol. Results: The WO-DCA plans successfully "agreed" with the standard VMAT for OAR (liver, spinal cord, stomach, duodenum, small bowel, and heart) and PTV (D-mean, D-98%, D-2%, CI, and GI), with superior mean quality assurance (QA) pass rate (97.06 vs 93.00 for VMAT; P < 0.001 and t = 8.87). Similarly, the WO-DCA technique additionally reduced the beam-on time (3.26 vs 4.43; P < 0.001) and monitor unit (1860 vs 2705 for VMAT; P < 0.001) values significantly. Conclusion: The WO-DCA plans might minimize small-field dosimetry errors and defeat patient-specific VMAT QA requirements due to the omission of MLC beam modulation through the target volume. The WO-DCA plans may additionally enable faster treatment delivery times and lower OAR without sacrificing target doses in SBRT of liver tumors away from critical structures.
引用
收藏
页码:1053 / 1064
页数:12
相关论文
共 50 条
  • [1] A novel and clinically useful weight-optimized dynamic conformal arc in stereotactic radiation therapy of non-small cell lung cancer: Dosimetric comparison of treatment plans with volumetric-modulated arc therapy
    Saglam, Yucel
    Selek, Ugur
    Bolukbasi, Yasemin
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 203
  • [2] A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT
    Stathakis, Sotirios
    Narayanasamy, Ganesh
    Licon, Anna Laura
    Myers, Pamela
    Li, Ying
    Crownover, Richard
    Papanikolaou, Niko
    [J]. JOURNAL OF BUON, 2019, 24 (02): : 838 - 843
  • [3] Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy
    Bokrantz, Rasmus
    Wedenberg, Minna
    Sandwall, Peter
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 103 - 109
  • [4] A novel and clinically useful dynamic conformal arc (DCA)-based VMAT planning technique for lung SBRT
    Pokhrel, Damodar
    Visak, Justin
    Sanford, Lana
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 29 - 38
  • [5] Dosimetric comparison of dynamic conformal arc integrated with segment shape optimization and variable dose rate versus volumetric C modulated arc therapy for liver SBRT
    Thaper, Deepak
    Kamal, Rose
    Singh, Gaganpreet
    Oinam, Arun S.
    Yadav, Hanuman P.
    Kumar, Rishabh
    Kumar, Vivek
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (04) : 667 - 677
  • [6] A novel weight optimized dynamic conformal arcs with TrueBeam™ Linac for very small tumors (≤1 cc) with single isocenter of multiple brain metastases (2≤, ≥4) in stereotactic radiosurgery: A comparison with volumetric modulated arc therapy
    Saglam, Yucel
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (05) : 1297 - 1304
  • [7] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    [J]. MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [8] Abdominal Compression During Liver Stereotactic Body Radiation Therapy (SBRT) by Volumetric Modulated Arc Therapy (VMAT) Affords Significant Liver Sparing
    Snider, J. W., III
    Molitoris, J.
    Zhang, B.
    Chuong, M. D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S116 - S117
  • [9] A Retrospective Review on Stereotactic Radiosurgery Cases Planned with Dynamic Conformal Arcs Versus Volumetric Modulated Arc Therapy
    Cui, Y.
    Gao, H.
    Kirkpatrick, J. P.
    Yin, F. F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E211 - E212
  • [10] Lung SBRT: Dosimetric and Treatment Time Comparison of Volumetric-Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Clinically Treated Cases
    Han, J.
    Xu, Z.
    Baker, J.
    Hsia, A.
    Ryu, S.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3610 - 3610