Dosimetric comparison of dynamic conformal arc integrated with segment shape optimization and variable dose rate versus volumetric C modulated arc therapy for liver SBRT

被引:12
|
作者
Thaper, Deepak [1 ,3 ]
Kamal, Rose [1 ,3 ]
Singh, Gaganpreet [1 ,2 ]
Oinam, Arun S. [2 ]
Yadav, Hanuman P. [3 ]
Kumar, Rishabh [3 ]
Kumar, Vivek [1 ]
机构
[1] Panjab Univ, Ctr Med Phys, Chandigarh, India
[2] PGIMER, Dept Radiotherapy, Reg Canc Ctr, Chandigarh 160012, India
[3] Inst Liver & Biliary Sci, Dept Radiat Oncol, New Delhi, India
关键词
DCA; VDR; SSO; VMAT; SBRT; Dosimetric; BODY RADIATION-THERAPY; HEAD-AND-NECK; RADIOTHERAPY; VMAT;
D O I
10.1016/j.rpor.2020.04.017
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: The aim is a dosimetric comparison of dynamic conformal arc integrated with the segment shape optimization and variable dose rate (DCA_SSO_VDR) versus VMAT for liver SBRT and interaction of various treatment plan quality indices with PTV and degree of modulation (DoM) for both techniques. Background: The DCA is the state-of-the-art technique but overall inferior to VMAT, and the DCA_SSO_VDR technique was not studied for liver SBRT. Materials and methods: Twenty-five patients of liver SBRT treated using the VMAT technique were selected. DCA_SSO_VDR treatment plans were also generated for all patients in Monaco TPS using the same objective constraint template and treatment planning parameters as used for the VMAT technique. For comparison purpose, organs at risk (OARs) doses and treatment plans quality indices, such as maximum dose of PTV (D-max%), mean dose of PTV (D-mean%), maximum dose at 2 cm in any direction from the PTV (D-2cm%), total monitor units (MU's), gradient index R-50%, degree of modulation (DoM), conformity index (CI), homogeneity index (HI), and healthy tissue mean dose (HTMD) were compared. Results: Significant dosimetric differences were observed in several OARs doses and lowered in VMAT plans. The D-2(cm)%, R-50(%), CI, HI and HTMD are dosimetrically inferior in DCA_SSO_VDR plans. The higher DoM results in poor dose gradient and better dose gradient for DCA_SSO_VDR and VMAT treatment plans, respectively. Conclusions: For liver SBRT, DCA_SSO_VDR treatment plans are neither dosimetrically superior nor better alternative to the VMAT delivery technique. A reduction of 69.75% MU was observed in DCA_SSO_VDR treatment plans. For the large size of PTV and high DoM, DCA_SSO_VDR treatment plans result in poorer quality. (C) 2020 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:667 / 677
页数:11
相关论文
共 50 条
  • [1] A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT
    Stathakis, Sotirios
    Narayanasamy, Ganesh
    Licon, Anna Laura
    Myers, Pamela
    Li, Ying
    Crownover, Richard
    Papanikolaou, Niko
    [J]. JOURNAL OF BUON, 2019, 24 (02): : 838 - 843
  • [2] Variable Gantry and Dose Rate Conformal Arc for Lung and Liver SBRT
    Stathakis, S.
    Crownover, R. L.
    Saenz, D.
    Kirby, N.
    Rasmussen, K.
    Papanikolaou, N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E500 - E500
  • [3] Dosimetric Analysis and Comparison of Volumetric Modulated Arc Therapy Versus Intensity Modulated Radiation Therapy For Liver Carcinoma
    Chiang, B.
    Schnell, E.
    Hibbitts, K.
    Herman, T.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E750 - E750
  • [4] Dosimetric comparison among dynamic conformal arc therapy, coplanar and non-coplanar volumetric modulated arc therapy for single brain metastasis
    Torizuka, Daichi
    Uto, Megumi
    Takehana, Keiichi
    Mizowaki, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2021, 62 (06) : 1114 - 1119
  • [5] Dosimetric comparison of flattened and unflattened beams for stereotactic body radiation therapy: Impact of the size of the PTV on dynamic conformal arc and volumetric modulated arc therapy
    Vieillevigne, Laure
    Bessieres, Sandra
    Ouali, Monia
    Lanaspeze, Christel
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (11): : 1405 - 1414
  • [6] VOLUMETRIC MODULATED INTENSITY MODULATED ARC THERAPY FOR STEREOTACTIC LUNG RADIOTHERAPY: CONSTANT DOSE RATE VERSUS VARIABLE DOSE RATE DELIVERY
    Dogan, N.
    Wu, Y.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S499 - S499
  • [7] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [8] A comparison of robustness of volumetric modulated arc therapy and dynamic conformal arc therapy for lung stereotactic body radiation therapy
    Teague, Kathlina M.
    Miller, Daniel C.
    Nyamwanda, Jacqueline A.
    Prichard, Hugh A.
    Kirk, Michael C.
    [J]. MEDICAL DOSIMETRY, 2022, 47 (01) : 110 - 110
  • [9] Comparison of Volumetric-Modulated Arc Therapy plans using constant dose rate and variable dose rate options
    Nagarajan, R.
    Srinivas, P. V.
    Mangesh, D.
    Rupal, C.
    Aadesh, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S186 - S186
  • [10] Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery
    Molinier, Jessica
    Kerr, Christine
    Simeon, Sebastien
    Ailleres, Norbert
    Charissoux, Marie
    Azria, David
    Fenoglietto, Pascal
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 92 - 101