A dosimetric comparison between volumetric-modulated arc therapy and dynamic conformal arc therapy in SBRT

被引:8
|
作者
Stathakis, Sotirios [1 ]
Narayanasamy, Ganesh [1 ,2 ]
Licon, Anna Laura [1 ]
Myers, Pamela [3 ]
Li, Ying [1 ]
Crownover, Richard [1 ]
Papanikolaou, Niko [1 ]
机构
[1] Univ Texas Hlth San Antonio, Dept Radiat Oncol, Mays Canc Ctr, San Antonio, TX 78229 USA
[2] Univ Arkansas Med Sci, Dept Radiat Oncol, Little Rock, AR 72205 USA
[3] Baylor Coll Med, Houston, TX 77030 USA
来源
JOURNAL OF BUON | 2019年 / 24卷 / 02期
关键词
DCAT; Lower MUs; OAR sparing; SBRT; VMAT; RADIOTHERAPY;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The purpose of this study was to investigate the dosimetric equivalency of dynamic conformal arc therapy (DCAT) against volumetric modulated arc therapy (VMAT) plans in stereotactic body radiation therapy (SBRT) of lung and liver lesions and to examine if efficiency can be increased. Methods: Nineteen patients previously treated for lung and liver cancer lesions with SBRT were included. Organs at risk (OAR) and targets were contoured by a single radiation oncologist. All plans were optimized by the same dosimetrist using ELEKTA Monaco treatment planning system version 5.0 for 6MV flattening filter free (FFF) photon beam in a VersaHD (ELEKTA, Crawley, UK). A VMAT and DCAT plan was optimized using the same objectives using coplanar arcs of 225 degrees arc span. Results: All plans have achieved the target and OAR planning objectives. The target dose conformity was comparable (mean VMAT PTVr=1.3 and DCAT PTVr=1.4), and the low dose spillage were similar (mean VMAT R50=4.5 and DCAT R50=4.6). However, monitor units (MU) for DCAT plans were lower by 2.5 times on average than VMAT plans. It was observed that in 75% of cases where OARs overlapped with the PTV, maximum doses to OAR were higher in VMAT than DCAT plans, but the difference was not significant. Patient specific quality assurance (QA) plans were measured using the Scandidos Delta4 phantom and gamma analysis performed using 2mm distance to agreement (DTA) and 2% dose difference yielded more than 95% passing rates on both VMAT and DCAT plans. Conclusions: DCAT delivery for lung and liver SBRT is a dosimetrically equivalent and an efficient alternative to VMAT plans.
引用
收藏
页码:838 / 843
页数:6
相关论文
共 50 条
  • [1] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [2] Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery
    Molinier, Jessica
    Kerr, Christine
    Simeon, Sebastien
    Ailleres, Norbert
    Charissoux, Marie
    Azria, David
    Fenoglietto, Pascal
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 92 - 101
  • [3] Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma
    Liu, Xia
    Liu, Zhikai
    Pang, Tingtian
    Dong, Tingting
    Qiu, Jie
    [J]. PEDIATRIC INVESTIGATION, 2020, 4 (03) : 186 - 191
  • [4] Dosimetric comparison of tomotherapy and volumetric-modulated arc therapy for children with neuroblastoma
    Liu Xia
    Liu Zhikai
    Pang Tingtian
    Dong Tingting
    Qiu Jie
    [J]. 儿科学研究(英文), 2020, 04 (03) : 186 - 191
  • [5] Dosimetric comparison between dual-isocentric dynamic conformal arc therapy and mono-isocentric volumetric-modulated arc therapy for two large brain metastases
    Uto, Megumi
    Mizowaki, Takashi
    Ogura, Kengo
    Mukumoto, Nobutaka
    Katagiri, Tomohiro
    Takehana, Keiichi
    Hiraoka, Masahiro
    [J]. JOURNAL OF RADIATION RESEARCH, 2018, 59 (06) : 774 - 781
  • [6] Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy
    Bokrantz, Rasmus
    Wedenberg, Minna
    Sandwall, Peter
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 103 - 109
  • [7] Dosimetric comparison of hybrid volumetric-modulated arc therapy, volumetric-modulated arc therapy, and intensity-modulated radiation therapy for left-sided early breast cancer
    Lin, Jia-Fu
    Yeh, Dah-Cherng
    Yeh, Hui-Ling
    Chang, Chen-Fa
    Lin, Jin-Ching
    [J]. MEDICAL DOSIMETRY, 2015, 40 (03) : 262 - 267
  • [8] Dosimetric Effect of Jaw Tracking in Volumetric-Modulated Arc Therapy
    Thongsawad, Sangutid
    Khamfongkhruea, Chirasak
    Tannanonta, Chirapha
    [J]. JOURNAL OF MEDICAL PHYSICS, 2018, 43 (01) : 52 - 57
  • [9] Dosimetric comparison between jaw tracking and static jaw modes in volumetric-modulated arc therapy
    Hsieh, Y. T.
    Chou, C. Y.
    Huang, B. S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S880 - S880
  • [10] Dosimetric Comparison of Volumetric-Modulated Arc Therapy and Dynamic Conformal Arc Therapy in Three-fraction Single-isocenter Stereotactic Radiosurgery for Multiple Brain Metastases
    Turkkan, Gorkem
    Bilici, Nazli
    Sertel, Huseyin
    Tavli, Busra
    Ozkirim, Muge
    Fayda, Merdan
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (01): : 67 - 73