Effects of bismuth breast shielding on iodine quantification in dual-energy computed tomography: an experimental phantom study

被引:2
|
作者
Jang, Hyunsik [1 ]
Hur, Jin [1 ]
Choi, Byoung Wook [1 ]
Im, Dong Jin [1 ]
Hong, Yoo Jin [1 ]
Kim, Young Jin [1 ]
Lee, Hye-Jeong [1 ]
机构
[1] Yonsei Univ, Severance Hosp, Coll Med, Dept Radiol,Res Inst Radiol Sci, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Bismuth; dual-energy computed tomography; iodine; radiation protection; radiation dosage; THORACIC CT; IONIZING-RADIATION; IMAGE QUALITY; TUBE-CURRENT; CANCER; REDUCTION;
D O I
10.1177/0284185118768098
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Although the bismuth breast shield can reduce radiation exposure to the breast during dual-energy computed tomography (DECT), it can potentially affect material quantification on DECT due to artifacts. Purpose: To evaluate the effects of bismuth breast shielding on iodine quantification and radiation exposure in DECT. Material and Methods: Small balloons were made with 0.2%, 0.6% and 1.0% blended iodinated contrast (370 mg/mL of iodine) with water. The balloons were located at both anterior and posterior lungs in an adult anthropomorphic chest phantom. DECT was performed with and without breast shielding. Afterwards, iodine concentration values were measured for each balloon on the iodine maps. Absorbed radiation doses in the breast were measured with the optically stimulated luminescence dosimeter. Results: After shielding, we obtained significantly decreased iodine quantification for all three concentrations with 0.78 +/- 0.13 to 0.46 +/- 0.13 mg/mL, 2.31 +/- 0.17 to 1.68 +/- 0.19 mg/mL, and 3.82 +/- 0.10 to 2.84 +/- 0.20 mg/mL at the anterior location, and 0.72 +/- 0.11 to 0.48 +/- 0.09 mg/mL, 2.24 +/- 0.13 to 1.87 +/- 0.21 mg/mL, and 3.75 +/- 0.16 to 3.15 +/- 0.14 mg/mL at the posterior location for the 0.2%, 0.6%, and 1.0% balloons, respectively (P = 0.001 for all). After shielding, absorbed radiation doses to the breast significantly decreased by 14.8% (4.32 +/- 0.33 to 3.68 +/- 0.30 mGy; P= 0.005). Conclusion: Although using the bismuth breast shield may decrease radiation exposure to the breast on DECT, it may also significantly affect iodine quantification.
引用
收藏
页码:1475 / 1481
页数:7
相关论文
共 50 条
  • [41] Evaluation of Intra-Manufacturer Dual-Energy CT Iodine Quantification Accuracy: Phantom Studies
    Zhao, A.
    Borhani, A.
    Catania, R.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [42] Dual-Energy Computed Tomography Dose Reduction, Series Reduction, and Contrast Load Reduction in Dual-Energy Computed Tomography
    Parakh, Anushri
    Macri, Francesco
    Sahani, Dushyant
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 601 - +
  • [43] GOUT AT THE SPINE: A RETROSPECTIVE STUDY WITH DUAL-ENERGY COMPUTED TOMOGRAPHY
    Chotard, E.
    Sverzut, J. M.
    Liote, F.
    Bardin, T.
    Ea, H-K.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 367 - 368
  • [44] Segmentation and quantification of materials with energy discriminating computed tomography: A phantom study
    Le, Huy Q.
    Molloi, Sabee
    MEDICAL PHYSICS, 2011, 38 (01) : 228 - 237
  • [45] Accuracy of Quantification of Iodine and Hounsfield Unit Values on Virtual Monochromatic Imaging Using Dual-Energy Computed Tomography: Comparison of Dual-Layer Computed Tomography With Fast Kilovolt-Switching Computed Tomography
    Washio, Hayate
    Ohira, Shingo
    Karino, Tsukasa
    Nitta, Yuya
    Hayashi, Masaaki
    Miyazaki, Masayoshi
    Teshima, Teruki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 965 - 971
  • [46] The feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping
    Boellaard, T. N.
    Henneman, O. D. F.
    Streekstra, G. J.
    Venema, H. W.
    Nio, C. Y.
    van Dorth-Rombouts, M. C.
    Stoker, J.
    CLINICAL RADIOLOGY, 2013, 68 (08) : 799 - 806
  • [47] Dual-energy computed tomography iodine quantification combined with laboratory data for predicting microvascular invasion in hepatocellular carcinoma: a two-centre study
    Li, Huan
    Zhang, Dai
    Pei, Jinxia
    Hu, Jingmei
    Li, Xiaohu
    Liu, Bin
    Wang, Longsheng
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1160): : 1467 - 1475
  • [48] Pancreatic Iodine Density and Fat Fraction on Dual-Energy Computed Tomography in Acute Pancreatitis
    Kastelan, Zrinka Matana
    Brumini, Ivan
    Poropat, Goran
    Tkalcic, Lovro
    Grubesic, Tiana
    Miletic, Damir
    DIAGNOSTICS, 2024, 14 (09)
  • [49] Feasibility Study to Demonstrate Cardiac Imaging using fast kVp switching dual-energy computed tomography: Phantom Study
    Madhav, Priti
    Imai, Yasuhiro
    Narayanan, Suresh
    Dutta, Sandeep
    Chandra, Naveen
    Hsieh, Jiang
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [50] Dual-energy computed tomography diagnostics for gout
    Rech, H. J.