Accuracy of Quantification of Iodine and Hounsfield Unit Values on Virtual Monochromatic Imaging Using Dual-Energy Computed Tomography: Comparison of Dual-Layer Computed Tomography With Fast Kilovolt-Switching Computed Tomography

被引:16
|
作者
Washio, Hayate [1 ]
Ohira, Shingo [1 ]
Karino, Tsukasa [1 ]
Nitta, Yuya [1 ]
Hayashi, Masaaki [2 ]
Miyazaki, Masayoshi [1 ]
Teshima, Teruki [1 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Hyogo Yoka Hosp, Dept Radiol, Yabu, Hyogo, Japan
关键词
dual-energy CT; iodine concentration; virtual monochromatic imaging; fast kilovoltage-switching CT; dual-layer CT; NONMETASTATIC LYMPH-NODES; MULTIDETECTOR CT; SPECTRAL CT; DIFFERENTIATION; PRINCIPLES; CARCINOMA; CYST; CELL;
D O I
10.1097/RCT.0000000000000798
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of the study was to compare the accuracy of quantification of iodine and Hounsfield unit (HU) values on virtual monochromatic imaging (VMI) using dual-layer computed tomography (DLCT) and fast kilovolt-switching computed tomography (FKSCT). Materials and Methods This study was performed in 2 phantoms (large and small) using 16 rods representing different materials (iodine, calcium, blood, and adipose tissue) with different dimensions and concentrations. The absolute percentage errors (absolute ratio of measurement error to true iodine concentration) for iodine concentration and HU value on VMI at 50, 70, and 100 keV were compared between DLCT and FKSCT. The Mann-Whitney U test was used to assess statistical significance. Results Overall, the absolute percentage errors for iodine concentration and HU value on VMI were smaller for DLCT than for FKSCT. Conclusions Overall, the accuracy of iodine and HU values was higher for DLCT than for FKSCT.
引用
收藏
页码:965 / 971
页数:7
相关论文
共 50 条
  • [1] Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing
    Taguchi, Narumi
    Oda, Seitaro
    Imuta, Masanori
    Yamamura, Sadahiro
    Yokota, Yasuhiro
    Nakaura, Takeshi
    Nagayama, Yasunori
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Baba, Hideo
    Yamashita, Yasuyuki
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 7 - 12
  • [2] Variation in Hounsfield unit calculated using dual-energy computed tomography: comparison of dual-layer, dual-source, and fast kilovoltage switching technique
    Ohira, Shingo
    Mochizuki, Junji
    Niwa, Tatsunori
    Endo, Kazuyuki
    Minamitani, Masanari
    Yamashita, Hideomi
    Katano, Atsuto
    Imae, Toshikazu
    Nishio, Teiji
    Koizumi, Masahiko
    Nakagawa, Keiichi
    [J]. RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 458 - 466
  • [3] Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors
    Tanoue, Shota
    Nakaura, Takeshi
    Nagayama, Yasunori
    Uetani, Hiroyuki
    Ikeda, Osamu
    Yamashita, Yasuyuki
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (06) : 951 - 958
  • [4] Accuracy of iodine quantification using dual-energy computed tomography with focus on low concentrations
    Ahnfelt, Anders
    Dahlman, Par
    Segelsjo, Monica
    Magnusson, Mats O.
    Magnusson, Anders
    [J]. ACTA RADIOLOGICA, 2022, 63 (05) : 623 - 631
  • [5] Measurement of Vascular Diameter in Computed Tomography Angiography With Reduced Iodine Load: Comparison of Virtual Monochromatic Imaging in Dual-Energy Computed Tomography and Conventional Polychromatic Scan In Vitro
    Sugawara, Haruto
    Suzuki, Shigeru
    Katada, Yoshiaki
    Ishikawa, Takuya
    Fukui, Rika
    Yamamoto, Yuzo
    Abe, Osamu
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 919 - 924
  • [6] Iodine Quantification Using Dual-Energy Computed Tomography for Differentiating Thymic Tumors
    Yan, Wei-Qiang
    Xin, Yong-Kang
    Jing, Yong
    Li, Gang-Feng
    Wang, Shu-Mei
    Rong, Wei-Cheng
    Xiao, Gang
    Lei, Xue-Bin
    Li, Bo
    Hu, Yu-Chuan
    Cui, Guang-Bin
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 873 - 880
  • [7] Imaging of nanoparticles with dual-energy computed tomography
    Ducote, J. L.
    Alivov, Y.
    Molloi, S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07): : 2031 - 2044
  • [8] Dual-Energy Computed Tomography in Genitourinary Imaging
    Mileto, Achille
    Marin, Daniele
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2017, 55 (02) : 373 - +
  • [9] Dual-Energy Computed Tomography in Body Imaging
    Toia, Giuseppe V.
    Kim, Sooah
    Dighe, Manjiri K.
    Mileto, Achille
    [J]. SEMINARS IN ROENTGENOLOGY, 2018, 53 (02) : 132 - 146
  • [10] Dual-Energy Computed Tomography in Cardiac Imaging
    Boettcher, Benjamin
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Schoepf, Uwe Joseph
    Meinel, Felix G.
    van Assen, Marly
    De Cecco, Carlo N.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 995 - 1009