Imaging of nanoparticles with dual-energy computed tomography

被引:14
|
作者
Ducote, J. L. [1 ]
Alivov, Y. [1 ]
Molloi, S. [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 07期
关键词
VULNERABLE ATHEROSCLEROTIC PLAQUE; GOLD NANOPARTICLES; CONTRAST AGENT; OPTIMIZATION; CT; MAMMOGRAPHY; MACROPHAGES; DENSITY;
D O I
10.1088/0031-9155/56/7/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A simulation study was performed to determine the feasibility and performance of imaging nanoparticles as contrast agents in dual-energy computed tomography. An analytical simulation model was used to model the relevant signal-to-noise ratio (SNR) in dual-energy imaging for the specific case of a three-material patient phantom consisting of water, calcium hydroxyapatite and contrast agent. Elemental gold and iodine were both considered as contrast agents. Simulations were performed for a range of monoenergetic (20150 keV) and polyenergetic (20-150 kVp) beam spectra. A reference configuration was defined with beam energies of 80 and 140 kVp to match current clinical practice. The effect of adding a silver filter to the high-energy beam was also studied. A figure of merit (FOM), which normalized the dual-energy SNR to the square root of the patient integral dose, was calculated for all cases. The units of the FOM were keV (1/2). A simple Rose model of detectability was used to estimate the minimum concentration of either elements needed to be detected (SNR > 5). For monoenergetic beams, the peak FOM of gold was 6.4 x 10(-6) keV(-1/2), while the peak FOM of iodine was 3.1 x 10-6 keV-1/2, a factor of approximately 2 greater for gold. For polyenergetic spectra, at the reference energies of 80 and 140 kVp, the FOM for gold and iodine was 1.65 x 10(-6) and 5.0 x 10(-7) keV(-1/2), respectively, a factor of approximately 3.3 greater. Also at these energies, the minimum detectable concentration of gold was estimated to be 58.5 mg mL(-1), while iodine was estimated to be 117.5 mg mL(-1). The results suggest that the imaging of a gold nanoparticle contrast agent is well suited to current conditions used in clinical imaging. The addition of a silver filter of 800 mu m further increased the image quality of the gold signal by approximately 50% for the same absorbed dose to the patient.
引用
收藏
页码:2031 / 2044
页数:14
相关论文
共 50 条
  • [1] Dual-Energy Computed Tomography in Genitourinary Imaging
    Mileto, Achille
    Marin, Daniele
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2017, 55 (02) : 373 - +
  • [2] Dual-Energy Computed Tomography in Cardiac Imaging
    Boettcher, Benjamin
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Schoepf, Uwe Joseph
    Meinel, Felix G.
    van Assen, Marly
    De Cecco, Carlo N.
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 995 - 1009
  • [3] Dual-energy Computed Tomography Imaging of the Aorta
    Vlahos, Ioannis
    Godoy, Myrna C. B.
    Naidich, David P.
    [J]. JOURNAL OF THORACIC IMAGING, 2010, 25 (04) : 289 - 300
  • [4] Dual-Energy Computed Tomography in Body Imaging
    Toia, Giuseppe V.
    Kim, Sooah
    Dighe, Manjiri K.
    Mileto, Achille
    [J]. SEMINARS IN ROENTGENOLOGY, 2018, 53 (02) : 132 - 146
  • [5] Dual-Energy Computed Tomography in Cardiothoracic Vascular Imaging
    De Santis, Domenico
    Eid, Marwen
    De Cecco, Carlo N.
    Jacobs, Brian E.
    Albrecht, Moritz H.
    Varga-Szemes, Akos
    Tesche, Christian
    Caruso, Damiano
    Laghi, Andrea
    Schoepf, Uwe Joseph
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (04) : 521 - +
  • [6] The utility of dual-energy computed tomography in abdominal imaging
    Del Gaizo, Andrew J.
    Silva, Alvin C.
    Hara, Amy K.
    [J]. APPLIED RADIOLOGY, 2014, 43 (01) : 12 - +
  • [7] Vascular Imaging: Utilization of Dual-Energy Computed Tomography
    Ahmed Alharthy
    Matthew D’Mello
    Hatim Alabsi
    Nicolas Murray
    Omar Metwally
    Khaled Y. Elbanna
    Mohammed F. Mohammed
    Faisal Khosa
    [J]. Current Radiology Reports, 7
  • [8] Oncological Applications of Dual-Energy Computed Tomography Imaging
    Paul, Jijo
    Vogl, Thomas J.
    Mbalisike, Emmanuel C.
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 834 - 842
  • [9] Dual-energy computed tomography imaging of myocardial infarction
    Ruzsics, B
    Chiaramida, SA
    Schoepf, UJ
    [J]. HEART, 2009, 95 (03) : 180 - 180
  • [10] The Role of Dual-Energy Computed Tomography in Musculoskeletal Imaging
    Fukuda, Takeshi
    Fukuda, Kunihiko
    [J]. PET CLINICS, 2018, 13 (04) : 567 - 578