Effects of bismuth breast shielding on iodine quantification in dual-energy computed tomography: an experimental phantom study

被引:2
|
作者
Jang, Hyunsik [1 ]
Hur, Jin [1 ]
Choi, Byoung Wook [1 ]
Im, Dong Jin [1 ]
Hong, Yoo Jin [1 ]
Kim, Young Jin [1 ]
Lee, Hye-Jeong [1 ]
机构
[1] Yonsei Univ, Severance Hosp, Coll Med, Dept Radiol,Res Inst Radiol Sci, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Bismuth; dual-energy computed tomography; iodine; radiation protection; radiation dosage; THORACIC CT; IONIZING-RADIATION; IMAGE QUALITY; TUBE-CURRENT; CANCER; REDUCTION;
D O I
10.1177/0284185118768098
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Although the bismuth breast shield can reduce radiation exposure to the breast during dual-energy computed tomography (DECT), it can potentially affect material quantification on DECT due to artifacts. Purpose: To evaluate the effects of bismuth breast shielding on iodine quantification and radiation exposure in DECT. Material and Methods: Small balloons were made with 0.2%, 0.6% and 1.0% blended iodinated contrast (370 mg/mL of iodine) with water. The balloons were located at both anterior and posterior lungs in an adult anthropomorphic chest phantom. DECT was performed with and without breast shielding. Afterwards, iodine concentration values were measured for each balloon on the iodine maps. Absorbed radiation doses in the breast were measured with the optically stimulated luminescence dosimeter. Results: After shielding, we obtained significantly decreased iodine quantification for all three concentrations with 0.78 +/- 0.13 to 0.46 +/- 0.13 mg/mL, 2.31 +/- 0.17 to 1.68 +/- 0.19 mg/mL, and 3.82 +/- 0.10 to 2.84 +/- 0.20 mg/mL at the anterior location, and 0.72 +/- 0.11 to 0.48 +/- 0.09 mg/mL, 2.24 +/- 0.13 to 1.87 +/- 0.21 mg/mL, and 3.75 +/- 0.16 to 3.15 +/- 0.14 mg/mL at the posterior location for the 0.2%, 0.6%, and 1.0% balloons, respectively (P = 0.001 for all). After shielding, absorbed radiation doses to the breast significantly decreased by 14.8% (4.32 +/- 0.33 to 3.68 +/- 0.30 mGy; P= 0.005). Conclusion: Although using the bismuth breast shield may decrease radiation exposure to the breast on DECT, it may also significantly affect iodine quantification.
引用
收藏
页码:1475 / 1481
页数:7
相关论文
共 50 条
  • [31] Verification of in-phantom x-ray energy spectra in dual-energy computed tomography
    Ishii, T.
    Numamoto, H.
    Hirai, Y.
    Koyama, S.
    Kawano, M.
    Ohashi, K.
    Proceedings of the 20th EGS Users' Meeting in Japan, 2013, : 9 - 14
  • [32] Toward Biphasic Computed Tomography (CT) Enteric Contrast: Material Classification of Luminal Bismuth and Mural Iodine in a Small-Bowel Phantom Using Dual-Energy CT
    Qu, Mingliang
    Ehman, Eric
    Fletcher, Joel G.
    Huprich, James E.
    Hara, Amy K.
    Silva, Alvin C.
    Farrugia, Gianrico
    Limburg, Paul
    McCollough, Cynthia H.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (05) : 554 - 559
  • [33] Quantification of Metal Artifact Reduction of Dual-Energy CT: A Phantom Study
    Li, K.
    Leung, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3036 - 3036
  • [34] Prediction of microvascular invasion of hepatocellular carcinoma: value of volumetric iodine quantification using preoperative dual-energy computed tomography
    Taek Min Kim
    Jeong Min Lee
    Jeong Hee Yoon
    Ijin Joo
    Sae-Jin Park
    Sun Kyung Jeon
    Bernhard Schmidt
    Sedlmair Martin
    Cancer Imaging, 20
  • [35] Correlation of Quantitative Dual-Energy Computed Tomography Iodine Maps and Abdominal Computed Tomography Perfusion Measurements Are Single-Acquisition Dual-Energy Computed Tomography Iodine Maps More Than a Reduced-Dose Surrogate of Conventional Computed Tomography Perfusion?
    Stiller, Wolfram
    Skornitzke, Stephan
    Fritz, Franziska
    Klauss, Miriam
    Hansen, Jens
    Pahn, Gregor
    Grenacher, Lars
    Kauczor, Hans-Ulrich
    INVESTIGATIVE RADIOLOGY, 2015, 50 (10) : 703 - 708
  • [36] Prediction of microvascular invasion of hepatocellular carcinoma: value of volumetric iodine quantification using preoperative dual-energy computed tomography
    Kim, Taek Min
    Lee, Jeong Min
    Yoon, Jeong Hee
    Joo, Ijin
    Park, Sae-Jin
    Jeon, Sun Kyung
    Schmidt, Bernhard
    Martin, Sedlmair
    CANCER IMAGING, 2020, 20 (01)
  • [37] Dual-Energy Multidetector Computed Tomography With Iodine Quantification in the Evaluation of Portal Vein Thrombosis: Is It Possible to Discard the Unenhanced Phase?
    Ascenti, Giorgio
    Sofia, Carmelo
    Silipigni, Salvatore
    Vinci, Sergio
    Pergolizzi, Stefano
    Marin, Daniele
    Mileto, Achille
    Mazziotti, Silvio
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2015, 66 (04): : 348 - 355
  • [38] Accuracy of iodine removal using dual-energy CT with or without a tin filter: an experimental phantom study
    Kawai, Tatsuya
    Takeuchi, Mitsuru
    Hara, Masaki
    Ohashi, Kazuya
    Suzuki, Hirochika
    Yamada, Kiyotaka
    Sugimura, Yuya
    Shibamoto, Yuta
    ACTA RADIOLOGICA, 2013, 54 (08) : 954 - 960
  • [39] Comparison of enhancement quantification from virtual unenhanced images to true unenhanced images in multiphase renal Dual-Energy computed tomography: A phantom study
    Popnoe, D. Olivia
    Ng, Chaan S.
    Zhou, Shouhao
    Kappadath, Cheenu
    Pan, Tinsu
    Jones, A. Kyle
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (08): : 171 - 179
  • [40] Quantification of bone quality and distribution of the proximal humerus with dual-energy computed tomography
    Yu, Qinqin
    Yang, Jia
    Zhou, Chenwei
    Xu, Zhihan
    Liu, Chao
    Luo, Qian
    Zhang, Lei
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (09) : 5676 - 5687