Feasibility Study to Demonstrate Cardiac Imaging using fast kVp switching dual-energy computed tomography: Phantom Study

被引:2
|
作者
Madhav, Priti [1 ]
Imai, Yasuhiro [1 ]
Narayanan, Suresh [1 ]
Dutta, Sandeep [1 ]
Chandra, Naveen [1 ]
Hsieh, Jiang [1 ]
机构
[1] GE Healthcare Syst, Waukesha, WI 53188 USA
关键词
Computed tomography; Dual-energy CT; Cardiac Imaging; Fast kVp-switching; Monochromatic CT; Material Density; Beam hardening; MYOCARDIAL CT PERFUSION;
D O I
10.1117/12.911526
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dual-energy computed tomography is a novel imaging tool that has the potential to reduce beam hardening artifacts and enhance material separation over conventional imaging techniques. Dual-energy acquisitions can be performed by using a fast kVp technology to switch between acquiring adjacent projections at two distinct x-ray spectra (80 and 140 kVp). These datasets can be used to further compute material density and monochromatic images for better material separation and beam hardening reduction by virtue of the projection domain process. The purpose of this study was to evaluate the feasibility of using dual-energy in cardiac imaging for myocardial perfusion detection and coronary artery lumen visualization. Data was acquired on a heart phantom, which consisted of the chambers and aorta filled with Iodine density solution (500 HU @ 120 kVp), a defect region between the aorta and chamber (40 HU @ 120 kVp), two Iodine-filled vessels (400 HU @ 120 kVp) of different diameters with high attenuation (hydroxyapatite) plaques (HAP), and with a 30-cm water equivalent body ring around the phantom. Prospective ECG-gated single-energy and prospective ECG-gated dual-energy imaging was performed. Results showed that the generated monochromatic images had minimal beam hardening artifacts which improved the accuracy and detection of the myocardial defect region. Material density images were useful in differentiating and quantifying the actual size of the plaque and coronary artery lumen. Overall, this study shows that dual-energy cardiac imaging will be a valuable tool for cardiac applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] EVALUATION OF PATIENT EXPOSURE IN FAST KVP SWITCHING DUAL ENERGY COMPUTED TOMOGRAPHY: PHANTOM STUDY
    Yagami, K.
    Miyoshi, T.
    Shigeyama, S.
    Takai, H.
    Tsukahara, Y.
    Matsumoto, K.
    Suzuki, R.
    Yasuda, N.
    Okada, H.
    Suzuki, S.
    Foley, S. J.
    RADIATION PROTECTION DOSIMETRY, 2018, 181 (03) : 261 - 268
  • [2] Automated Liver Lesion Characterization using fast kVp switching Dual Energy Computed Tomography Imaging
    Santamaria-Pang, Alberto
    Dutta, Sandeep
    Makrogiannis, Sokratis
    Hara, Amy
    Pavlicek, William
    Silva, Alvin
    Thomsen, Brian
    Robertson, Scott
    Okerlund, Darin
    Langan, David A.
    Bhotika, Rahul
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [3] Dual-Energy Computed Tomography in Cardiac Imaging
    Boettcher, Benjamin
    Zsarnoczay, Emese
    Varga-Szemes, Akos
    Schoepf, Uwe Joseph
    Meinel, Felix G.
    van Assen, Marly
    De Cecco, Carlo N.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (06) : 995 - 1009
  • [4] Validation of Virtual Monochromatic Images and Effect of Body Size Obtained Using a Rapid kVp-switching Dual-energy Computed Tomography System: A Phantom Study
    Wu, Tung-Hsin
    Ting, Yun-Lung
    Hwang, Yi-Shuan
    Chui, Chen-Shou
    Lin, Cristopher K. J.
    HEALTH PHYSICS, 2022, 123 (04): : 287 - 294
  • [5] Computation of Calcium Score With Dual-Energy Computed Tomography: A Phantom Study
    Kumar, Vidhya
    Min, James K.
    He, Xin
    Raman, Subha V.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (01) : 156 - 158
  • [6] Assessment of hepatic fatty infiltration using dual-energy computed tomography: a phantom study
    Li, Jung-Hui
    Tsai, Chang-Yu
    Huang, Hsuan-Ming
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (04) : 597 - 606
  • [7] The Feasibility of Dual-Energy Computed Tomography in Cardiac Contusion Imaging for Mildest Blunt Cardiac Injury
    Sade, Recep
    Kantarci, Mecit
    Ogul, Hayri
    Bayraktutan, Ummugulsum
    Uzkeser, Mustafa
    Aslan, Sahin
    Aksakal, Enbiya
    Becit, Necip
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (03) : 354 - 359
  • [8] Development of a dual-energy computed tomography quality control program: Characterization of scanner response and definition of relevant parameters for a fast-kVp switching dual-energy computed tomography system
    Nute, Jessica L.
    Jacobsen, Megan C.
    Stefan, Wolfgang
    Wei, Wei
    Cody, Dianna D.
    MEDICAL PHYSICS, 2018, 45 (04) : 1444 - 1458
  • [9] Aortic Endograft Surveillance: Use of Fast-Switch kVp Dual-Energy Computed Tomography With Virtual Noncontrast Imaging
    Maturen, Katherine E.
    Kleaveland, Patricia A.
    Kaza, Ravi K.
    Liu, Peter S.
    Quint, Leslie E.
    Khalatbari, Shokoufeh H.
    Platt, Joel F.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (06) : 742 - 746
  • [10] In vivo quantification of bone mineral density of lumbar vertebrae using fast kVp switching dual-energy CT: correlation with quantitative computed tomography
    Zhou, Shuwei
    Zhu, Lu
    You, Tian
    Li, Ping
    Shen, Hongrong
    He, Yewen
    Gao, Hui
    Yan, Luyou
    He, Zhuo
    Guo, Ying
    Zhang, Yaxi
    Zhang, Kun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (01)