Feasibility Study to Demonstrate Cardiac Imaging using fast kVp switching dual-energy computed tomography: Phantom Study

被引:2
|
作者
Madhav, Priti [1 ]
Imai, Yasuhiro [1 ]
Narayanan, Suresh [1 ]
Dutta, Sandeep [1 ]
Chandra, Naveen [1 ]
Hsieh, Jiang [1 ]
机构
[1] GE Healthcare Syst, Waukesha, WI 53188 USA
关键词
Computed tomography; Dual-energy CT; Cardiac Imaging; Fast kVp-switching; Monochromatic CT; Material Density; Beam hardening; MYOCARDIAL CT PERFUSION;
D O I
10.1117/12.911526
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dual-energy computed tomography is a novel imaging tool that has the potential to reduce beam hardening artifacts and enhance material separation over conventional imaging techniques. Dual-energy acquisitions can be performed by using a fast kVp technology to switch between acquiring adjacent projections at two distinct x-ray spectra (80 and 140 kVp). These datasets can be used to further compute material density and monochromatic images for better material separation and beam hardening reduction by virtue of the projection domain process. The purpose of this study was to evaluate the feasibility of using dual-energy in cardiac imaging for myocardial perfusion detection and coronary artery lumen visualization. Data was acquired on a heart phantom, which consisted of the chambers and aorta filled with Iodine density solution (500 HU @ 120 kVp), a defect region between the aorta and chamber (40 HU @ 120 kVp), two Iodine-filled vessels (400 HU @ 120 kVp) of different diameters with high attenuation (hydroxyapatite) plaques (HAP), and with a 30-cm water equivalent body ring around the phantom. Prospective ECG-gated single-energy and prospective ECG-gated dual-energy imaging was performed. Results showed that the generated monochromatic images had minimal beam hardening artifacts which improved the accuracy and detection of the myocardial defect region. Material density images were useful in differentiating and quantifying the actual size of the plaque and coronary artery lumen. Overall, this study shows that dual-energy cardiac imaging will be a valuable tool for cardiac applications.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Dual-energy Computed Tomography (DECT) Scan for Determination of Renal Stone Composition: A Phantom Study
    Sheikhi, Mahboobeh
    Sina, Sedigheh
    Karimipourfard, Mehrnoosh
    IRANIAN JOURNAL OF RADIOLOGY, 2023, 20 (03)
  • [22] Investigating the feasibility of generating dual-energy CT from one 120-kVp CT scan: a phantom study
    Huang, Wen-Hui
    Jhan, Kai-Jie
    Yang, Ching-Ching
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02): : 126 - 137
  • [23] Dual-Energy Computed Tomography Applications to Reduce Metal Artifacts in Hip Prostheses: A Phantom Study
    Conti, Daniele
    Baruffaldi, Fabio
    Erani, Paolo
    Festa, Anna
    Durante, Stefano
    Santoro, Miriam
    DIAGNOSTICS, 2023, 13 (01)
  • [24] Improvement with the Multi-material Decomposition Framework in Dual-energy Computed Tomography: A Phantom Study
    Lee, Haenghwa
    Kim, Hee-Joung
    Lee, Donghoon
    Kim, Dohyeon
    Choi, Seungyeon
    Lee, Minjae
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (06) : 515 - 523
  • [25] Quality evaluation of monoenergetic images generated by dual-energy computed tomography for radiotherapy: A phantom study
    Pawalowski, Bartosz
    Szweda, Hubert
    Dudkowiak, Alina
    Piotrowski, Tomasz
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 63 : 48 - 55
  • [26] Validation of Virtual Monochromatic Images and Effect of Body Size Obtained Using a Rapid kVp-switching Dual-energy Computed Tomography System: A Phantom Study (vol 123, pg 287, 2022)
    Wu, Tung-Hsin
    Ting, Yun-Lung
    Hwang, Yi-Shuan
    Chui, Chen-Shou
    Lin, Cristopher K. J.
    HEALTH PHYSICS, 2023, 124 (05): : 427 - 427
  • [27] Improvement with the Multi-material Decomposition Framework in Dual-energy Computed Tomography: A Phantom Study
    Haenghwa Lee
    Hee-Joung Kim
    Donghoon Lee
    Dohyeon Kim
    Seungyeon Choi
    Minjae Lee
    Journal of the Korean Physical Society, 2020, 77 : 515 - 523
  • [28] Accuracy of Quantification of Iodine and Hounsfield Unit Values on Virtual Monochromatic Imaging Using Dual-Energy Computed Tomography: Comparison of Dual-Layer Computed Tomography With Fast Kilovolt-Switching Computed Tomography
    Washio, Hayate
    Ohira, Shingo
    Karino, Tsukasa
    Nitta, Yuya
    Hayashi, Masaaki
    Miyazaki, Masayoshi
    Teshima, Teruki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 965 - 971
  • [29] Dual-energy digital mammography for calcification imaging: A phantom study
    Kappadath, SC
    Shaw, C
    Lai, C
    Liu, X
    Whitman, G
    MEDICAL PHYSICS, 2004, 31 (06) : 1797 - 1797
  • [30] Study of the Natural Crystalline Lens Characteristics Using Dual-Energy Computed Tomography
    Sachs, Jeffrey R.
    Nahmias, Javier A.
    Hiatt, Kevin D.
    Bomar, James G.
    West, Thomas G.
    Bunch, Paul M.
    Benayoun, Marc D.
    Lack, Chris
    Thompson, Atalie C.
    DIAGNOSTICS, 2022, 12 (11)