Fire tests of South African cross-laminated timber wall panels: fire ratings, charring rates, and delamination

被引:4
|
作者
van der Westhuyzen, S. [1 ]
Walls, R. [1 ]
de Koker, N. [1 ]
机构
[1] Stellenbosch Univ, Dept Civil Engn, Private Bag X1, ZA-7602 Mateiland, South Africa
关键词
structural fire engineering; cross-laminated timber (CLT); charring rates; delamination;
D O I
10.17159/2309-8775/2020/v62n1a4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) is a product consisting of multiple timber layers (lamina) face-glued together to form structural wall and flooring systems. Internationally its use is growing rapidly, although its fire resistance is a topic of ongoing research. This study investigates the fire resistance of CLT wall panels manufactured locally from South African pine and eucalyptus, the most commonly used timber species for CLT in South Africa, through SANS10177-2 compliant fire tests of two 100 mm (33-33-33) thick CLT wall panel samples with dimensions of 0.9 m x 0.9 m. In addition to insulation and integrity fire resistance ratings, the study characterises the charring rate and delamination behaviour of CLT. The recommended integrity and insulation fire resistance ratings for the 100 mm thick SA pine and eucalyptus CLT samples is 60 minutes and 90 minutes respectively. The average charring rate calculated for the SA pine CLT and eucalyptus CLT panels was 0.95 mm/min and 0.76 mm/min respectively. These values are higher than charring rates for bulk timber, due to significant delamination observed in both tests. Associated structural fire resistance rating was estimated for each CLT panel by rational design, giving structural resistance times of 29 mins and 36 mins for the SA pine and eucalyptus CLT, respectively. These times are notably smaller than the insulation and integrity fire ratings reported above, but are only relevant to load-bearing walls. As a result, the tested CLT panels can only be used in multi-storey timber buildings as non-loading bearing walls.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 50 条
  • [41] Fire resistance of unprotected cross-laminated timber (CLT) floor assemblies produced in the USA
    Muszynski, Lech
    Gupta, Rakesh
    Hong, Seung Hyun
    Osborn, Neil
    Pickett, Brent
    FIRE SAFETY JOURNAL, 2019, 107 : 126 - 136
  • [42] Numerical simulation of fire integrity resistance of full-scale gypsum-faced cross-laminated timber wall
    Thi, V. D.
    Khelifa, M.
    Oudjene, M.
    El Ganaoui, M.
    Rogaume, Y.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2018, 132 : 96 - 103
  • [43] Behaviour of Cross-Laminated Timber Slabs Subjected to Fire-A State-Of-The-Art Review
    Barclay, Sarah
    Salem, Sam
    PROCEEDINGS OF THE CANADIAN SOCIETY OF CIVIL ENGINEERING ANNUAL CONFERENCE 2022, VOL 4, CSCE 2022, 2024, 367 : 183 - 198
  • [44] Description of small and large-scale cross laminated timber fire tests
    Emberley, Richard
    Putynska, Carmen Gorska
    Bolanos, Aaron
    Lucherini, Andrea
    Solarte, Angela
    Soriguer, Diana
    Gonzalez, Mateo Gutierrez
    Humphreys, Kathryn
    Hidalgo, Juan P.
    Maluk, Cristian
    Law, Angus
    Torero, Jose L.
    FIRE SAFETY JOURNAL, 2017, 91 : 327 - 335
  • [45] Behaviour of Cross-Laminated Timber Slabs Subjected to Fire-A State-Of-The-Art Review
    Barclay, Sarah
    Salem, Sam
    PROCEEDINGS OF THE CANADIAN SOCIETY OF CIVIL ENGINEERING ANNUAL CONFERENCE 2022, VOL 3, CSCE 2022, 2024, 359 : 183 - 198
  • [46] Structural response of fire-exposed cross-laminated timber beams under sustained loads
    Lineham, Sean A.
    Thomson, Daniel
    Bartlett, Alastair I.
    Bisby, Luke A.
    Hadden, Rory M.
    FIRE SAFETY JOURNAL, 2016, 85 : 23 - 34
  • [47] Numerical Analysis of Fire Resistance in Cross-Laminated Timber (CLT) Constructions Using CFD: Implications for Structural Integrity and Fire Protection
    Perkovic, Nikola
    Skejic, Davor
    Rajcic, Vlatka
    FORESTS, 2024, 15 (11):
  • [48] Experimental study of cross-laminated timber wall panels [Experimentelle Untersuchung von Wandelementen aus Brettsperrholz]
    Vessby J.
    Enquist B.
    Petersson H.
    Alsmarker T.
    European Journal of Wood and Wood Products, 2009, 67 (2) : 211 - 218
  • [49] Structural Integrity Assessment of Two-Story Cross-Laminated Timber House Under Fire Load
    Uhrin, Robert
    Gregor, Michal
    Stompf, Patrik
    Stefko, Jozef
    WOOD & FIRE SAFETY 2024, WFS 2024, 2024, : 308 - 316
  • [50] Fire spread in a large compartment with exposed cross-laminated timber and open ventilation conditions: #FRIC-02-Exposed wall and ceiling
    Boe, Andreas Saeter
    Friquin, Kathinka Leikanger
    Brandon, Daniel
    -Hansen, Anne Steen
    Ertesvag, Ivar S.
    FIRE SAFETY JOURNAL, 2023, 141