Fire resistance of unprotected cross-laminated timber (CLT) floor assemblies produced in the USA

被引:24
|
作者
Muszynski, Lech [1 ]
Gupta, Rakesh [1 ]
Hong, Seung Hyun [1 ]
Osborn, Neil [1 ]
Pickett, Brent [2 ]
机构
[1] Oregon State Univ, Dept Wood Sci & Engn, 119 Richardson Hall, Corvallis, OR 97331 USA
[2] Western Fire Ctr, 2204 Parrott Way, Kelso, WA 98626 USA
关键词
Fire performance; Cross-laminated timber; CLT; Floors; Half-lap joints; PUR; MF;
D O I
10.1016/j.firesaf.2018.12.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fire concerns are one reason for building code restrictions against tall wood buildings in US. Despite growing body of empirical data on fire performance of cross-laminated timber (CLT) generated in Europe and Canada, lack of full-scale tests performed on structural CLT "made in the USA" is often quoted as a barrier for approval of massive timber in tall buildings in the US. The goal of this project was to contribute towards removing this barrier by testing the fire resistance of three full-scale unprotected CLT floor assemblies fabricated by two US-based manufacturers. The assemblies represented two species groups (SPF and DF-L), and two adhesive systems (PUR and MF). All assemblies ma ASTM E119 standard qualifying criteria for 2-h fire rating in loaded condition. While char fall-off was observed in assemblies bonded with PUR, the differences in mean char rates in the first two layers between assemblies bonded with PUR and MF were smaller than the variability of char rates within individual assemblies. Statistical significant difference was observed only for cumulative char rate for the entire time of exposure. The effect of softening of the PUR bonds was most apparent as an accelerated rate of assembly deflection in the late stage of the tests. The unprotected half-lap joints provided adequate barrier against transmission of ha gases and flames through the assemblies.
引用
收藏
页码:126 / 136
页数:11
相关论文
共 50 条
  • [1] Simulation of the Fire Resistance of Cross-laminated Timber (CLT)
    Schmid, Joachim
    Klippel, Michael
    Just, Alar
    Frangi, Andrea
    Tiso, Mattia
    FIRE TECHNOLOGY, 2018, 54 (05) : 1113 - 1148
  • [2] Simulation of the Fire Resistance of Cross-laminated Timber (CLT)
    Joachim Schmid
    Michael Klippel
    Alar Just
    Andrea Frangi
    Mattia Tiso
    Fire Technology, 2018, 54 : 1113 - 1148
  • [3] Fire resistance of unprotected cross-laminated timber floor panels: Parametric study and simplified design
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    FIRE SAFETY JOURNAL, 2019, 107 : 104 - 113
  • [4] Numerical Investigation of the Fire Resistance of Protected Cross-Laminated Timber Floor Panels
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    STRUCTURAL ENGINEERING INTERNATIONAL, 2012, 22 (04) : 523 - 532
  • [5] Thermal performance of cross-laminated timber (CLT) and cross-laminated bamboo and timber (CLBT) panels
    Shan, Bo
    Chen, Bozhang
    Wen, Jie
    Xiao, Yan
    ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2023, 19 (05) : 511 - 530
  • [6] Ballistic performance of Cross-laminated Timber (CLT)
    Sanborn, K.
    Gentry, T. R.
    Koch, Z.
    Valkenburg, A.
    Conley, C.
    Stewart, L. K.
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2019, 128 : 11 - 23
  • [7] Numerical Analysis of Cross-Laminated Timber (CLT) Wall Panels Under Fire
    Yasir, Muhammad
    Ruane, Kieran
    Jaksic, Vesna
    WOOD & FIRE SAFETY 2024, WFS 2024, 2024, : 27 - 35
  • [8] Design of Cross-Laminated Timber in Fire
    Klippel, Michael
    Schmid, Joachim
    STRUCTURAL ENGINEERING INTERNATIONAL, 2017, 27 (02) : 224 - 230
  • [9] Cross-laminated timber (CLT) - a state of the art report
    Jelec, Mario
    Varevac, Damir
    Rajcic, Vlatka
    GRADEVINAR, 2018, 70 (02): : 75 - 95
  • [10] Fire behaviour of cross-laminated timber
    Klippel, Michael
    Frangi, Andrea
    BAUTECHNIK, 2016, 93 (08) : 567 - 572