Fire resistance of unprotected cross-laminated timber floor panels: Parametric study and simplified design

被引:10
|
作者
Menis, Agnese [1 ]
Fragiacomo, Massimo [2 ]
Clemente, Isaia [3 ]
机构
[1] Via Valerio 77-2, I-34127 Trieste, Italy
[2] Univ Aquila, Dept Civil Construct Architecture & Environm Engn, Via Giovanni Gronchi 18, I-67100 Laquila, Italy
[3] Univ Trieste, Dept Civil Engn & Architecture, Piazzale Europa 1, I-34127 Trieste, Italy
关键词
Cross-laminated timber; Finite element; Fire resistance; Floor; Reduced cross-section method; Simplified design method; Wood;
D O I
10.1016/j.firesaf.2018.02.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The larger use of cross-laminated timber (XLAM) panels as structural elements has taken the attention of the practitioners and researchers on their design in fire conditions. Simplified analytical design methods for fire resistance of timber structures are provided by the current European standard namely the EN 1995-1-2, however no provisions for XLAM floor panel are provided. The paper presents the results of a parametric investigation carried out on unprotected XLAM floor panels with different build-ups (number of layers, layer thickness, panel depth) exposed to standard fire on the bottom side and subjected to different load levels. Both advanced numerical simulations and analytical simplified methods are used to derive applied load-fire resistance design curves. Conservative approximations are proposed for XLAM floor elements with three, five and seven layers that do not show falling off of charred layers during the standard fire exposure. The proposed plots together with some tabular values allow a direct and conservative estimation of the fire resistance depending upon the applied load and the panel build-up.
引用
收藏
页码:104 / 113
页数:10
相关论文
共 50 条
  • [1] Numerical Investigation of the Fire Resistance of Protected Cross-Laminated Timber Floor Panels
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    STRUCTURAL ENGINEERING INTERNATIONAL, 2012, 22 (04) : 523 - 532
  • [2] Fire resistance of unprotected cross-laminated timber (CLT) floor assemblies produced in the USA
    Muszynski, Lech
    Gupta, Rakesh
    Hong, Seung Hyun
    Osborn, Neil
    Pickett, Brent
    FIRE SAFETY JOURNAL, 2019, 107 : 126 - 136
  • [3] Modelling the fire resistance of cross-laminated timber rib panels
    Kleinhenz, Miriam
    Palma, Pedro
    Just, Alar
    Frangi, Andrea
    FIRE AND MATERIALS, 2024, 48 (07) : 725 - 736
  • [4] Fire Resistance of Cross-Laminated Timber Panels Loaded Out of Plane
    Fragiacomo, Massimo
    Menis, Agnese
    Clemente, Isaia
    Bochicchio, Giovanna
    Ceccotti, Ario
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (12)
  • [5] Fire Resistance of Large-Scale Cross-Laminated Timber Panels
    Henek, Vladan
    Venkrbec, Vaclav
    Novotny, Miloslav
    WORLD MULTIDISCIPLINARY EARTH SCIENCES SYMPOSIUM (WMESS 2017), 2017, 95
  • [6] Design of Cross-Laminated Timber in Fire
    Klippel, Michael
    Schmid, Joachim
    STRUCTURAL ENGINEERING INTERNATIONAL, 2017, 27 (02) : 224 - 230
  • [7] Experimental analysis of cross-laminated timber panels in fire
    Frangi, Andrea
    Fontana, Mario
    Hugi, Erich
    Joebstl, Robert
    FIRE SAFETY JOURNAL, 2009, 44 (08) : 1078 - 1087
  • [8] Scaling study on the fire resistance of cross-laminated timber floors
    Bai, Yu
    Zhang, Jin
    Zhang, Xilin
    JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [9] The Structural Behaviour of Cross-Laminated Timber Rib Panels in Fire
    Kleinhenz, Miriam
    Just, Alar
    Frangi, Andrea
    FIRE TECHNOLOGY, 2024, 60 (04) : 2651 - 2673
  • [10] Simulation of the Fire Resistance of Cross-laminated Timber (CLT)
    Schmid, Joachim
    Klippel, Michael
    Just, Alar
    Frangi, Andrea
    Tiso, Mattia
    FIRE TECHNOLOGY, 2018, 54 (05) : 1113 - 1148