Fire tests of South African cross-laminated timber wall panels: fire ratings, charring rates, and delamination

被引:4
|
作者
van der Westhuyzen, S. [1 ]
Walls, R. [1 ]
de Koker, N. [1 ]
机构
[1] Stellenbosch Univ, Dept Civil Engn, Private Bag X1, ZA-7602 Mateiland, South Africa
关键词
structural fire engineering; cross-laminated timber (CLT); charring rates; delamination;
D O I
10.17159/2309-8775/2020/v62n1a4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) is a product consisting of multiple timber layers (lamina) face-glued together to form structural wall and flooring systems. Internationally its use is growing rapidly, although its fire resistance is a topic of ongoing research. This study investigates the fire resistance of CLT wall panels manufactured locally from South African pine and eucalyptus, the most commonly used timber species for CLT in South Africa, through SANS10177-2 compliant fire tests of two 100 mm (33-33-33) thick CLT wall panel samples with dimensions of 0.9 m x 0.9 m. In addition to insulation and integrity fire resistance ratings, the study characterises the charring rate and delamination behaviour of CLT. The recommended integrity and insulation fire resistance ratings for the 100 mm thick SA pine and eucalyptus CLT samples is 60 minutes and 90 minutes respectively. The average charring rate calculated for the SA pine CLT and eucalyptus CLT panels was 0.95 mm/min and 0.76 mm/min respectively. These values are higher than charring rates for bulk timber, due to significant delamination observed in both tests. Associated structural fire resistance rating was estimated for each CLT panel by rational design, giving structural resistance times of 29 mins and 36 mins for the SA pine and eucalyptus CLT, respectively. These times are notably smaller than the insulation and integrity fire ratings reported above, but are only relevant to load-bearing walls. As a result, the tested CLT panels can only be used in multi-storey timber buildings as non-loading bearing walls.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 50 条
  • [21] Experimental study of cross-laminated timber wall panels
    Vessby, Johan
    Enquist, Bertil
    Petersson, Hans
    Alsmarker, Tomas
    EUROPEAN JOURNAL OF WOOD AND WOOD PRODUCTS, 2009, 67 (02) : 211 - 218
  • [22] Simulation of the Fire Resistance of Cross-laminated Timber (CLT)
    Schmid, Joachim
    Klippel, Michael
    Just, Alar
    Frangi, Andrea
    Tiso, Mattia
    FIRE TECHNOLOGY, 2018, 54 (05) : 1113 - 1148
  • [23] Design Model for Fire Exposed Cross-Laminated Timber
    Schmid, J.
    Konig, J.
    Kohler, J.
    STRUCTURES IN FIRE: PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE, 2010, : 511 - +
  • [24] Enclosure fire dynamics with a cross-laminated timber ceiling
    McNamee, Robert
    Zehfuss, Jochen
    Bartlett, Alastair, I
    Heidari, Mohammad
    Robert, Fabienne
    Bisby, Luke A.
    FIRE AND MATERIALS, 2021, 45 (07) : 847 - 857
  • [25] Simulation of the Fire Resistance of Cross-laminated Timber (CLT)
    Joachim Schmid
    Michael Klippel
    Alar Just
    Andrea Frangi
    Mattia Tiso
    Fire Technology, 2018, 54 : 1113 - 1148
  • [26] Experimental study on charring rate of cross-laminated timber floor considering the effect of delamination
    Zhang J.
    Wu L.
    Liao J.
    Wang W.
    Li W.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2019, 49 (04): : 705 - 711
  • [27] Behavior of cross-laminated timber panels during and after an ISO-fire: An experimental analysis
    Vairo, Maurizio
    Silva, Valdir Pignatta
    Icimoto, Felipe Hideyoshi
    RESULTS IN ENGINEERING, 2023, 17
  • [28] Fire resistance of unprotected cross-laminated timber floor panels: Parametric study and simplified design
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    FIRE SAFETY JOURNAL, 2019, 107 : 104 - 113
  • [29] Sectional Analysis of Cross-Laminated Timber as a Design for Fire Methodology
    Bartlett, Alastair
    Hadden, Rory
    Bisby, Luke
    Lane, Barbara
    STRUCTURES IN FIRE, 2016, : 684 - 691
  • [30] Structural fire engineering considerations for cross-laminated timber walls
    Wiesner, Felix
    Hadden, Rory
    Deeny, Susan
    Bisby, Luke
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 323