Fire tests of South African cross-laminated timber wall panels: fire ratings, charring rates, and delamination

被引:4
|
作者
van der Westhuyzen, S. [1 ]
Walls, R. [1 ]
de Koker, N. [1 ]
机构
[1] Stellenbosch Univ, Dept Civil Engn, Private Bag X1, ZA-7602 Mateiland, South Africa
关键词
structural fire engineering; cross-laminated timber (CLT); charring rates; delamination;
D O I
10.17159/2309-8775/2020/v62n1a4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) is a product consisting of multiple timber layers (lamina) face-glued together to form structural wall and flooring systems. Internationally its use is growing rapidly, although its fire resistance is a topic of ongoing research. This study investigates the fire resistance of CLT wall panels manufactured locally from South African pine and eucalyptus, the most commonly used timber species for CLT in South Africa, through SANS10177-2 compliant fire tests of two 100 mm (33-33-33) thick CLT wall panel samples with dimensions of 0.9 m x 0.9 m. In addition to insulation and integrity fire resistance ratings, the study characterises the charring rate and delamination behaviour of CLT. The recommended integrity and insulation fire resistance ratings for the 100 mm thick SA pine and eucalyptus CLT samples is 60 minutes and 90 minutes respectively. The average charring rate calculated for the SA pine CLT and eucalyptus CLT panels was 0.95 mm/min and 0.76 mm/min respectively. These values are higher than charring rates for bulk timber, due to significant delamination observed in both tests. Associated structural fire resistance rating was estimated for each CLT panel by rational design, giving structural resistance times of 29 mins and 36 mins for the SA pine and eucalyptus CLT, respectively. These times are notably smaller than the insulation and integrity fire ratings reported above, but are only relevant to load-bearing walls. As a result, the tested CLT panels can only be used in multi-storey timber buildings as non-loading bearing walls.
引用
收藏
页码:33 / 41
页数:9
相关论文
共 50 条
  • [1] Experimental analysis of cross-laminated timber panels in fire
    Frangi, Andrea
    Fontana, Mario
    Hugi, Erich
    Joebstl, Robert
    FIRE SAFETY JOURNAL, 2009, 44 (08) : 1078 - 1087
  • [2] Numerical Analysis of Cross-Laminated Timber (CLT) Wall Panels Under Fire
    Yasir, Muhammad
    Ruane, Kieran
    Jaksic, Vesna
    WOOD & FIRE SAFETY 2024, WFS 2024, 2024, : 27 - 35
  • [3] Modelling the fire resistance of cross-laminated timber rib panels
    Kleinhenz, Miriam
    Palma, Pedro
    Just, Alar
    Frangi, Andrea
    FIRE AND MATERIALS, 2024, 48 (07) : 725 - 736
  • [4] The Structural Behaviour of Cross-Laminated Timber Rib Panels in Fire
    Kleinhenz, Miriam
    Just, Alar
    Frangi, Andrea
    FIRE TECHNOLOGY, 2024, 60 (04) : 2651 - 2673
  • [5] Design of Cross-Laminated Timber in Fire
    Klippel, Michael
    Schmid, Joachim
    STRUCTURAL ENGINEERING INTERNATIONAL, 2017, 27 (02) : 224 - 230
  • [6] Fire behaviour of cross-laminated timber
    Klippel, Michael
    Frangi, Andrea
    BAUTECHNIK, 2016, 93 (08) : 567 - 572
  • [7] Fire Resistance of Cross-Laminated Timber Panels Loaded Out of Plane
    Fragiacomo, Massimo
    Menis, Agnese
    Clemente, Isaia
    Bochicchio, Giovanna
    Ceccotti, Ario
    JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (12)
  • [8] Fire Resistance of Large-Scale Cross-Laminated Timber Panels
    Henek, Vladan
    Venkrbec, Vaclav
    Novotny, Miloslav
    WORLD MULTIDISCIPLINARY EARTH SCIENCES SYMPOSIUM (WMESS 2017), 2017, 95
  • [9] Experimental and numerical analysis of the fire behaviour of cross-laminated timber panels
    Frangi, Andrea
    Fontana, Mario
    Bochicchio, Giovanna
    BAUPHYSIK, 2007, 29 (06) : 387 - 397
  • [10] Experimental determination of the charring rate of cross-laminated timber panels
    Alanen, Mika
    Malaska, Mikko
    Salminen, Mikko
    Paavola, Pyry
    Pajunen, Sami
    FIRE SAFETY JOURNAL, 2024, 146