Intraoperative refraction for intraocular lens power calculation

被引:0
|
作者
Biancardi, Ana Luiza
Walsh, Aileen
Crema, Armando Stefano
机构
[1] Universidade Federal do Rio de Janeiro - UFRJ, Rio de Janeiro (RJ)
[2] Universidade Gama Filho - UGF, Rio de Janeiro (RJ)
关键词
Cataract; Intraocular lens; Biometry; Case report; DISCOLORATION; OPACIFICATION;
D O I
10.1590/S0034-72802011000200010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This paper describes the intraoperative refraction for intraocular lens (IOL) power calculation. Report a case of a 67 year-old male patient reporting a progressive loss of visual acuity in the left eye (OS). Examination revealed best corrected visual acuity (BCVA) of 20/60 (-21,50 -4,00 X 170) related to adherence of silicone oil to the IOL optic. IOL exchange was proposed, however biometry was variable and doubtful. Intraoperative refraction confirmed the IOL power and the patient underwent uneventful IOL explantation and exchange with a three-piece acrylic IOL. After surgery, examination revealed BCVA OS of 20/30 (-1,25 -1,25 X 180). Analysis of explanted IOL confirmed adherence of silicone oil to the IOL optic. Intraoperative refraction is useful to confirm IOL power calculation.
引用
收藏
页码:118 / 121
页数:4
相关论文
共 50 条
  • [21] Intraocular lens power calculation REPLY
    Jin, Haiying
    Rabsilber, Tanja T.
    Ehmer, Angela
    Borkenstein, Andreas F.
    Limberger, Il-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2177 - 2178
  • [22] Intraocular lens power calculation for microphthalmos
    Inatomi, M
    Ishii, K
    Koide, R
    Kora, Y
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (08): : 1208 - 1212
  • [23] Biometry and intraocular lens power calculation
    Lee, Alexander C.
    Qazi, Mujtaba A.
    Pepose, Jay S.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) : 13 - 17
  • [24] Calculation of intraocular lens power: a review
    Olsen, Thomas
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (05): : 472 - 485
  • [25] Theoretical evaluation of the cataract extraction-refraction-implantation techniques for intraocular lens power calculation
    Sheppard, Amy L.
    Dunne, Mark C. M.
    Wolffsohn, James S.
    Davies, Leon N.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (06) : 568 - 576
  • [26] Influence of the invariant refraction assumption in studies of formulas for monofocal and multifocal intraocular lens power calculation
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Martinez, Javier
    Burguera, Noemi
    Pinero, David
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (08) : 2417 - 2424
  • [27] Predicted Refraction Variability Due to Reliability of Nine Optical Biometers for Intraocular Lens Power Calculation
    Rocha-de-Lossada, Carlos
    Rodriguez-Vallejo, Manuel
    Rachwani-Anil, Rahul
    Burguera, Noemi
    Fernandez, Joaquin
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (02) : 120 - 127
  • [28] Influence of the invariant refraction assumption in studies of formulas for monofocal and multifocal intraocular lens power calculation
    Joaquín Fernández
    Manuel Rodríguez-Vallejo
    Javier Martínez
    Noemi Burguera
    David Piñero
    International Ophthalmology, 2022, 42 : 2417 - 2424
  • [29] Intraocular lens power calculation in eyes with keratoconus
    Garzon, Nuria
    Arriola-Villalobos, Pedro
    Felipe, Gema
    Poyales, Francisco
    Garcia-Montero, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05): : 778 - 783
  • [30] Advancements in intraocular lens power calculation formulas
    Chung, Jinkwon
    Bu, Jennifer J.
    Afshari, Natalie A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2022, 33 (01) : 35 - 40