Intraoperative refraction for intraocular lens power calculation

被引:0
|
作者
Biancardi, Ana Luiza
Walsh, Aileen
Crema, Armando Stefano
机构
[1] Universidade Federal do Rio de Janeiro - UFRJ, Rio de Janeiro (RJ)
[2] Universidade Gama Filho - UGF, Rio de Janeiro (RJ)
关键词
Cataract; Intraocular lens; Biometry; Case report; DISCOLORATION; OPACIFICATION;
D O I
10.1590/S0034-72802011000200010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This paper describes the intraoperative refraction for intraocular lens (IOL) power calculation. Report a case of a 67 year-old male patient reporting a progressive loss of visual acuity in the left eye (OS). Examination revealed best corrected visual acuity (BCVA) of 20/60 (-21,50 -4,00 X 170) related to adherence of silicone oil to the IOL optic. IOL exchange was proposed, however biometry was variable and doubtful. Intraoperative refraction confirmed the IOL power and the patient underwent uneventful IOL explantation and exchange with a three-piece acrylic IOL. After surgery, examination revealed BCVA OS of 20/30 (-1,25 -1,25 X 180). Analysis of explanted IOL confirmed adherence of silicone oil to the IOL optic. Intraoperative refraction is useful to confirm IOL power calculation.
引用
收藏
页码:118 / 121
页数:4
相关论文
共 50 条
  • [31] Intraocular lens power calculation in phacovitrectomy patients
    Partwardhan, Ashish A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04): : 529 - 529
  • [32] Intraocular lens power calculation following LASIK
    Jarade, EF
    Abinader, FC
    Tabbara, KF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U1179 - U1179
  • [33] Update on biometry and intraocular lens power calculation
    Hirnschall, Nino
    Findl, Oliver
    SPEKTRUM DER AUGENHEILKUNDE, 2020, 34 (5-6) : 137 - 143
  • [34] Intraocular lens power calculation in eyes with keratoconus
    Savini, Giacomo
    Abbate, Rosa
    Hoffer, Kenneth J.
    Mularoni, Alessandro
    Imburgia, Aurelio
    Avoni, Luca
    D'Eliseo, Domenico
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (05): : 576 - 581
  • [35] The SRKII formula in the calculation of intraocular lens power
    Nurözler, A
    Ünlü, N
    Yalvaç, IS
    Kasim, R
    Duman, S
    OPHTHALMOLOGICA, 1998, 212 (03) : 153 - 156
  • [36] Intraocular Lens Power Calculation: A Challenging Case
    Rosa, Nicola
    De Bernardo, Maddalena
    Iaccarino, Stefania
    Cennamo, Michela
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (02) : E29 - E31
  • [37] Ptosis effects on intraocular lens power calculation
    Aydemir, Emre
    Aydemir, Gozde Aksoy
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (02): : 171 - 176
  • [38] Sources of error in intraocular lens power calculation
    Norrby, Sverker
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 368 - 376
  • [39] Intraocular lens power calculation in short eyes
    Gavin, E. A.
    Hammond, C. J.
    EYE, 2008, 22 (07) : 935 - 938
  • [40] Intraocular lens power calculation for the equine eye
    Meister, Ulrike
    Gorig, Christiane
    Murphy, Christopher J.
    Haan, Hubertus
    Ohnesorge, Bernhard
    Boeve, Michael H.
    BMC VETERINARY RESEARCH, 2018, 14