Sequential and simultaneous determination of four elements in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry

被引:27
|
作者
Boschetti, W. [1 ]
Orlando, M. [1 ]
Dullius, M. [2 ]
Dessuy, M. B. [1 ,3 ]
Vale, M. G. R. [1 ,3 ]
Welz, B. [3 ,4 ]
de Andrade, J. B. [3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Vinicola Geisse, Linha Jansen S-N, BR-95700000 Pinto Bandeira, RS, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq INCT Energia & Ambiente, Salvador, BA, Brazil
[4] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
AGRICULTURAL SOILS; TRACE-ELEMENTS; HEAVY-METALS; ACID DIGESTION; SOLID SAMPLES; AQUA REGIA; CADMIUM; CR; FE; TOXICITY;
D O I
10.1039/c6ja00031b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method has been developed for the sequential and simultaneous determination of Cd, Cr, Fe and Al (via the AlH molecule) in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry and direct solid sample analysis. First, Cd (228.802 nm) was determined using 800 degrees C and 1700 degrees C as the pyrolysis and atomization temperatures, respectively. Subsequently, after changing the wavelength, Cr (425.433 nm), Fe (425.076 nm) and Al (425.315 nm) were determined simultaneously from the same sample aliquot using 2600 degrees C as the atomization (Cr and Fe) or vaporization (AlH) temperature. Al determination was carried out using the diatomic molecule AlH without adding a molecule-forming reagent. The interference caused by Al in Cd determination was minimized by using 10 mu L of a 10% v/v H2SO4 solution in all measurements. Aqueous standard solutions were used for calibration and the limits of detection and quantification obtained were 7.3 and 24 pg mg(-1) for Cd, 0.13 and 0.45 ng mg(-1) for Cr, 0.07 and 0.23 mu g mg(-1) for Fe and 0.42 and 1.4 mu g mg(-1) for Al, respectively. The concentration values for Cd, Cr, Fe and Al obtained from the soil certified reference material (CRM) Montana Soil I (NIST SRM 2710a) analysis were in agreement with the reported ones. The precision of the measurements, expressed as the relative standard deviation, was better than 10%. Six soil samples from a vineyard field were investigated and the results are in accordance with the Brazilian legislation.
引用
收藏
页码:1269 / 1277
页数:9
相关论文
共 50 条
  • [41] Direct Determination of Trace Elements in Meat Samples via High-Resolution Graphite Furnace Atomic Absorption Spectrometry
    Rodolpho M. de Andrade
    Jefferson S. de Gois
    Isabela Maia Toaldo
    Diego Barros Batista
    Aderval S. Luna
    Daniel L. G. Borges
    Food Analytical Methods, 2017, 10 : 1209 - 1215
  • [42] Determination of lead in coal using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gallindo Borges, DL
    da Silva, AF
    Curtius, AJ
    Welz, B
    Heitmann, U
    MICROCHIMICA ACTA, 2006, 154 (1-2) : 101 - 107
  • [43] Determination of Antimony in Pharmaceutical Formulations and Beverages Using High-Resolution Continuum-Source Graphite Furnace Atomic Absorption Spectrometry
    Mattiazzi, Patricia
    Bohrer, Denise
    Viana, Carine
    do Nascimento, Paulo Cicero
    Veiga, Marlei
    de Carvalho, Leandro Machado
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (03) : 737 - 743
  • [44] Determination of Lead in Coal Using Direct Solid Sampling and High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Daniel L. Gallindo Borges
    Alessandra Furtado da Silva
    Adilson José Curtius
    Bernhard Welz
    Uwe Heitmann
    Microchimica Acta, 2006, 154 : 101 - 107
  • [45] Optimization of high-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of selected trace elements in whole blood samples
    Wojciak-Kosior, Magdalena
    Szwerc, Wojciech
    Strzemski, Maciej
    Wichlacz, Zoltan
    Sawicki, Jan
    Kocjan, Ryszard
    Latalski, Michal
    Sowa, Ireneusz
    TALANTA, 2017, 165 : 351 - 356
  • [46] Indirect determination of cysteine in pharmaceutical formulations by high-resolution continuum source graphite furnace molecular absorption spectrometry
    Almeida, Jorge S.
    Meira, Lucilia A.
    Teixeira, Leonardo S. G.
    MICROCHEMICAL JOURNAL, 2018, 143 : 155 - 159
  • [47] Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry
    Lepri, Fabio G.
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Borges, Daniel L. G.
    Welz, Bernhard
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (08) : 934 - 944
  • [48] Solid sampling determination of total fluorine in baby food samples by high-resolution continuum source graphite furnace molecular absorption spectrometry
    Ozbek, Nil
    Akman, Suleyman
    FOOD CHEMISTRY, 2016, 211 : 180 - 184
  • [49] Determination of non-metals via molecular absorption using high-resolution continuum source absorption spectrometry and graphite furnace atomization
    Heitmann, Uwe
    Becker-Ross, Helmut
    Florek, Stefan
    Huang, Mao Dong
    Okruss, Michael
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) : 1314 - 1320
  • [50] Simultaneous Determination of Cd and Fe in Beans and Soil of Different Regions of Brazil Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry and Direct Solid Sampling
    dos Santos, Lisia M. G.
    Welz, Bernhard
    Araujo, Rennan G. O.
    Jacob, Silvana do C.
    Vale, Maria Goreti R.
    Martens, Andreas
    Gonzaga Martens, Irland B.
    Becker-Ross, Helmut
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (21) : 10089 - 10094