Sequential and simultaneous determination of four elements in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry

被引:27
|
作者
Boschetti, W. [1 ]
Orlando, M. [1 ]
Dullius, M. [2 ]
Dessuy, M. B. [1 ,3 ]
Vale, M. G. R. [1 ,3 ]
Welz, B. [3 ,4 ]
de Andrade, J. B. [3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Vinicola Geisse, Linha Jansen S-N, BR-95700000 Pinto Bandeira, RS, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq INCT Energia & Ambiente, Salvador, BA, Brazil
[4] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
AGRICULTURAL SOILS; TRACE-ELEMENTS; HEAVY-METALS; ACID DIGESTION; SOLID SAMPLES; AQUA REGIA; CADMIUM; CR; FE; TOXICITY;
D O I
10.1039/c6ja00031b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method has been developed for the sequential and simultaneous determination of Cd, Cr, Fe and Al (via the AlH molecule) in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry and direct solid sample analysis. First, Cd (228.802 nm) was determined using 800 degrees C and 1700 degrees C as the pyrolysis and atomization temperatures, respectively. Subsequently, after changing the wavelength, Cr (425.433 nm), Fe (425.076 nm) and Al (425.315 nm) were determined simultaneously from the same sample aliquot using 2600 degrees C as the atomization (Cr and Fe) or vaporization (AlH) temperature. Al determination was carried out using the diatomic molecule AlH without adding a molecule-forming reagent. The interference caused by Al in Cd determination was minimized by using 10 mu L of a 10% v/v H2SO4 solution in all measurements. Aqueous standard solutions were used for calibration and the limits of detection and quantification obtained were 7.3 and 24 pg mg(-1) for Cd, 0.13 and 0.45 ng mg(-1) for Cr, 0.07 and 0.23 mu g mg(-1) for Fe and 0.42 and 1.4 mu g mg(-1) for Al, respectively. The concentration values for Cd, Cr, Fe and Al obtained from the soil certified reference material (CRM) Montana Soil I (NIST SRM 2710a) analysis were in agreement with the reported ones. The precision of the measurements, expressed as the relative standard deviation, was better than 10%. Six soil samples from a vineyard field were investigated and the results are in accordance with the Brazilian legislation.
引用
收藏
页码:1269 / 1277
页数:9
相关论文
共 50 条
  • [31] Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry
    Alessandra Furtado da Silva
    Daniel L. G. Borges
    Fábio Grandis Lepri
    Bernhard Welz
    Adilson J. Curtius
    Uwe Heitmann
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1835 - 1841
  • [32] Sequential determination of Cd and Cr in biomass samples and their ashes using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Duarte, Alvaro T.
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Welz, Bernhard
    de Andrade, Jailson B.
    TALANTA, 2013, 115 : 55 - 60
  • [33] Investigation of spectral interferences in the determination of lead in fertilizers and limestone samples using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Borges, Aline R.
    Becker, Emilene M.
    Francois, Luciane L.
    de Jesus, Alexandre
    Vale, Maria Goreti R.
    Welz, Bernhard
    Dessuy, Morgana B.
    de Andrade, Jailson B.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 101 : 213 - 219
  • [34] Method development for the determination of cadmium in fertilizer samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and slurry sampling
    Borges, Aline R.
    Becker, Emilene M.
    Lequeux, Celine
    Vale, Maria Goreti R.
    Ferreira, Sergio L. C.
    Welz, Bernhard
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (07) : 529 - 535
  • [35] Determination of residual dimethyl sulfoxide by high-resolution continuum source graphite furnace molecular absorption spectrometry
    Huang, Mao Dong
    Esser, Norbert
    Hinrichs, Karsten
    Tan, Qin
    Rappich, Jorg
    Nickel, Norbert H.
    Dittrich, Thomas
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 177
  • [36] Determination of Total Sulfur in Food Samples by Solid Sampling High-Resolution Continuum Source Graphite Furnace Molecular Absorption Spectrometry
    Ozbek, Nil
    Akman, Suleyman
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2013, 61 (20) : 4816 - 4821
  • [37] Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers
    Abad, Carlos
    Florek, Stefan
    Becker-Ross, Helmut
    Huang, Mao-Dong
    Heinrich, Hans-Joachim
    Recknagel, Sebastian
    Vogl, Jochen
    Jakubowski, Norbert
    Panne, Ulrich
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 136 : 116 - 122
  • [38] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martin
    Garcia-Ruiz, Esperanza
    Garde, Raul
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) : 2233 - 2241
  • [39] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martín (mresano@unizar.es), 1600, Royal Society of Chemistry (31):
  • [40] Direct Determination of Trace Elements in Meat Samples via High-Resolution Graphite Furnace Atomic Absorption Spectrometry
    de Andrade, Rodolpho M.
    de Gois, Jefferson S.
    Toaldo, Isabela Maia
    Batista, Diego Barros
    Luna, Aderval S.
    Borges, Daniel L. G.
    FOOD ANALYTICAL METHODS, 2017, 10 (05) : 1209 - 1215