Sequential and simultaneous determination of four elements in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry

被引:27
|
作者
Boschetti, W. [1 ]
Orlando, M. [1 ]
Dullius, M. [2 ]
Dessuy, M. B. [1 ,3 ]
Vale, M. G. R. [1 ,3 ]
Welz, B. [3 ,4 ]
de Andrade, J. B. [3 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[2] Vinicola Geisse, Linha Jansen S-N, BR-95700000 Pinto Bandeira, RS, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq INCT Energia & Ambiente, Salvador, BA, Brazil
[4] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
AGRICULTURAL SOILS; TRACE-ELEMENTS; HEAVY-METALS; ACID DIGESTION; SOLID SAMPLES; AQUA REGIA; CADMIUM; CR; FE; TOXICITY;
D O I
10.1039/c6ja00031b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical method has been developed for the sequential and simultaneous determination of Cd, Cr, Fe and Al (via the AlH molecule) in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry and direct solid sample analysis. First, Cd (228.802 nm) was determined using 800 degrees C and 1700 degrees C as the pyrolysis and atomization temperatures, respectively. Subsequently, after changing the wavelength, Cr (425.433 nm), Fe (425.076 nm) and Al (425.315 nm) were determined simultaneously from the same sample aliquot using 2600 degrees C as the atomization (Cr and Fe) or vaporization (AlH) temperature. Al determination was carried out using the diatomic molecule AlH without adding a molecule-forming reagent. The interference caused by Al in Cd determination was minimized by using 10 mu L of a 10% v/v H2SO4 solution in all measurements. Aqueous standard solutions were used for calibration and the limits of detection and quantification obtained were 7.3 and 24 pg mg(-1) for Cd, 0.13 and 0.45 ng mg(-1) for Cr, 0.07 and 0.23 mu g mg(-1) for Fe and 0.42 and 1.4 mu g mg(-1) for Al, respectively. The concentration values for Cd, Cr, Fe and Al obtained from the soil certified reference material (CRM) Montana Soil I (NIST SRM 2710a) analysis were in agreement with the reported ones. The precision of the measurements, expressed as the relative standard deviation, was better than 10%. Six soil samples from a vineyard field were investigated and the results are in accordance with the Brazilian legislation.
引用
收藏
页码:1269 / 1277
页数:9
相关论文
共 50 条
  • [21] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (08) : 763 - 769
  • [22] Determination of Silver in Environmental Samples by High-resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry after Preconcentration on Bentonite
    Magdalena Krawczyk-Coda
    Journal of Analytical Chemistry, 2022, 77 : 1155 - 1161
  • [23] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    Da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    Journal of Analytical Atomic Spectrometry, 2006, 21 (08): : 763 - 769
  • [24] Determination of Silver in Environmental Samples by High-resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry after Preconcentration on Bentonite
    Krawczyk-Coda, Magdalena
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (09) : 1155 - 1161
  • [25] Determination of Pb and Cr in sunscreen samples by high-resolution continuum source graphite furnace atomic absorption spectrometry and direct analysis
    Zmozinski, Ariane V.
    Pretto, Tatiane
    Borges, Aline R.
    Duarte, Alvaro T.
    Vale, Maria Goreti R.
    MICROCHEMICAL JOURNAL, 2016, 128 : 89 - 94
  • [26] Sequential and Simultaneous Determination of Cd, Fe and Ni in Toothpastes Employing Slurry Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Silva, Arlene Santos
    Brandao, Geovani Cardoso
    Costa Ferreira, Sergio Luis
    Pinto dos Santos, Ana Maria
    ANALYTICAL LETTERS, 2022, 55 (08) : 1192 - 1206
  • [27] Simultaneous determination of iron and nickel in fluoropolymers by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Soares, Bruno M.
    Santos, Rafael F.
    Bolzan, Rodrigo C.
    Muller, Edson I.
    Primel, Ednei G.
    Duarte, Fabio A.
    TALANTA, 2016, 160 : 454 - 460
  • [28] Determination of germanium in plant and soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) with solid sampling
    Schreiter, Norbert
    Wiche, Oliver
    Aubel, Ines
    Roode-Gutzmer, Quirina
    Bertau, Martin
    JOURNAL OF GEOCHEMICAL EXPLORATION, 2021, 220
  • [29] Determination of chlorine in food samples via the AlCl molecule using high-resolution continuum source molecular absorption spectrometry in a graphite furnace
    Fechetia, Miriam
    Tognon, Andre Luiz
    da Veiga, Marcia A. M. S.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 98 - 101
  • [30] Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry
    da Silva, AF
    Borges, DLG
    Lepri, FG
    Welz, B
    Curtius, AJ
    Heitmann, U
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) : 1835 - 1841