Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry

被引:38
|
作者
Lepri, Fabio G.
Dessuy, Morgana B.
Vale, Maria Goreti R.
Borges, Daniel L. G.
Welz, Bernhard [1 ]
Heitmann, Uwe
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[3] ISAS, Inst Analyt Sci, Dept Interface Spect, D-12489 Berlin, Germany
关键词
phosphorus; electrothermal atomic absorption spectrometry; high-resolution continuum source atomic absorption spectrometry; chemical modifiers; molecular absorption;
D O I
10.1016/j.sab.2006.08.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Phosphorus is not one of the elements that are typically determined by atomic absorption spectrometry, but this technique nevertheless offers several advantages that make it attractive, such as the relatively great freedom from interferences. As the main resonance lines for phosphorus are in the vacuum-ultraviolet, inaccessible by conventional atomic absorption spectrometry equipment, L'vov and Khartsyzov proposed to use the non-resonance doublet at 213.5/213.6 nm. Later it turned out that with conventional equipment it is necessary to use a chemical modifier in order to get reasonable sensitivity, and lanthanum was the first one suggested for that purpose. In the following years more than 30 modifiers have been proposed for the determination of this element, and there is no consensus about the best one. In this work high-resolution continuum source atomic absorption spectrometry has been used to investigate the determination of phosphorus without a modifier and with the addition of selected modifiers of very different nature, including the originally recommended lanthanum modifier, several palladium-based modifiers and sodium fluoride. As high-resolution continuum source atomic absorption spectrometry is revealing the spectral environment of the analytical line at high resolution, it became obvious. that without the addition of a modifier essentially no atomic phosphorus is formed, even at 2700 degrees C. The absorption measured with line source atomic absorption spectrometry in this case is due to the PO molecule, the spectrum of which is overlapping with the atomic line. Palladium, with or without the addition of calcium or ascorbic acid, was found to be the only modifier to produce almost exclusively atomic phosphorus. Lanthanum and particularly sodium fluoride produced a mixture of P and PO, depending on the atomization temperature. This fact can explain at least some of the discrepancies found in the literature and some of the phenomena observed in the determination of phosphorus using line source atomic absorption spectrometry. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:934 / 944
页数:11
相关论文
共 50 条
  • [1] Investigation of chemical modifiers for the direct determination of arsenic in fish oil using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Pereira, Ederson R.
    de Almeida, Tarcisio S.
    Borges, Daniel L. G.
    Carasek, Eduardo
    Welz, Bernhard
    Feldmann, Joerg
    del Campo Menoyo, Javier
    TALANTA, 2016, 150 : 142 - 147
  • [2] Investigation of phosphorus atomization using high-resolution continuum source electrothermal atomic absorption spectrometry
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Lepri, Fabio G.
    Welz, Bernhard
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (05) : 429 - 434
  • [3] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martin
    Garcia-Ruiz, Esperanza
    Garde, Raul
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) : 2233 - 2241
  • [4] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martín (mresano@unizar.es), 1600, Royal Society of Chemistry (31):
  • [5] Investigation of chemical modifiers for sulfur determination in diesel fuel samples by high-resolution continuum source graphite furnace molecular absorption spectrometry using direct analysis
    Huber, Charles S.
    Vale, Maria Goreti R.
    Welz, Bernhard
    Andrade, Jailson B.
    Dessuy, Morgana B.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 108 : 68 - 74
  • [6] Determination of heavy metals in cigarettes using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Ren, Ting
    Chen, Xi
    Ge, Yao
    Zhao, Lijiao
    Zhong, Rugang
    ANALYTICAL METHODS, 2017, 9 (27) : 4033 - 4043
  • [7] Simultaneous determination of rhodium and ruthenium by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Zambrzycka-Szelewa, Elzbieta
    Lulewicz, Marta
    Godlewska-Zylkiewicz, Beata
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 133 : 81 - 87
  • [8] High-resolution continuum source graphite furnace atomic absorption spectrometry: Is it as good as it sounds? A critical review
    Resano, Martin
    Garcia-Ruiz, Esperanza
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (01) : 323 - 330
  • [9] Direct determination of P in biodiesel by high-resolution continuum source graphite furnace atomic absorption spectrometry
    de Campos, Reinaldo Calixto
    Correia, Carolina Lyrio T.
    Vieira, Flavia
    Saint'Pierre, Tatiana D.
    Oliveira, Ana Cristina
    Goncalves, Rodrigo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 352 - 355
  • [10] High-resolution continuum source graphite furnace atomic absorption spectrometry: Is it as good as it sounds? A critical review
    Martín Resano
    Esperanza García-Ruiz
    Analytical and Bioanalytical Chemistry, 2011, 399 : 323 - 330