Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry

被引:38
|
作者
Lepri, Fabio G.
Dessuy, Morgana B.
Vale, Maria Goreti R.
Borges, Daniel L. G.
Welz, Bernhard [1 ]
Heitmann, Uwe
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Quim, BR-91501970 Porto Alegre, RS, Brazil
[3] ISAS, Inst Analyt Sci, Dept Interface Spect, D-12489 Berlin, Germany
关键词
phosphorus; electrothermal atomic absorption spectrometry; high-resolution continuum source atomic absorption spectrometry; chemical modifiers; molecular absorption;
D O I
10.1016/j.sab.2006.08.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Phosphorus is not one of the elements that are typically determined by atomic absorption spectrometry, but this technique nevertheless offers several advantages that make it attractive, such as the relatively great freedom from interferences. As the main resonance lines for phosphorus are in the vacuum-ultraviolet, inaccessible by conventional atomic absorption spectrometry equipment, L'vov and Khartsyzov proposed to use the non-resonance doublet at 213.5/213.6 nm. Later it turned out that with conventional equipment it is necessary to use a chemical modifier in order to get reasonable sensitivity, and lanthanum was the first one suggested for that purpose. In the following years more than 30 modifiers have been proposed for the determination of this element, and there is no consensus about the best one. In this work high-resolution continuum source atomic absorption spectrometry has been used to investigate the determination of phosphorus without a modifier and with the addition of selected modifiers of very different nature, including the originally recommended lanthanum modifier, several palladium-based modifiers and sodium fluoride. As high-resolution continuum source atomic absorption spectrometry is revealing the spectral environment of the analytical line at high resolution, it became obvious. that without the addition of a modifier essentially no atomic phosphorus is formed, even at 2700 degrees C. The absorption measured with line source atomic absorption spectrometry in this case is due to the PO molecule, the spectrum of which is overlapping with the atomic line. Palladium, with or without the addition of calcium or ascorbic acid, was found to be the only modifier to produce almost exclusively atomic phosphorus. Lanthanum and particularly sodium fluoride produced a mixture of P and PO, depending on the atomization temperature. This fact can explain at least some of the discrepancies found in the literature and some of the phenomena observed in the determination of phosphorus using line source atomic absorption spectrometry. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:934 / 944
页数:11
相关论文
共 50 条
  • [21] Simultaneous Determination of Chromium and Iron in Powdered Milk Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Adilson S. Santos
    Cheilane T. de Souza
    Danilo J. Leao
    Felipo O. Correia
    Tarcísio S. Almeida
    Sergio L. C. Ferreira
    Food Analytical Methods, 2020, 13 : 284 - 290
  • [22] Simultaneous Determination of Chromium and Iron in Powdered Milk Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Santos, Adilson S.
    de Souza, Cheilane T.
    Leao, Danilo J.
    Correia, Felipo O.
    Almeida, Tarcisio S.
    Ferreira, Sergio L. C.
    FOOD ANALYTICAL METHODS, 2020, 13 (01) : 284 - 290
  • [23] Determination of Lead in Coal Using Direct Solid Sampling and High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Daniel L. Gallindo Borges
    Alessandra Furtado da Silva
    Adilson José Curtius
    Bernhard Welz
    Uwe Heitmann
    Microchimica Acta, 2006, 154 : 101 - 107
  • [24] Investigation of the feasibility to use Zeeman-effect background correction for the graphite furnace determination of phosphorus using high-resolution continuum source atomic absorption spectrometry as a diagnostic tool
    Lepri, Fabio G.
    Welz, Bernhard
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Bohrer, Denise
    de Loos-Vollebregt, Margaretha T. C.
    Huang, Mao Dong
    Becker-Ross, Helmut
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (01) : 24 - 32
  • [25] On the possibilities of high-resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous or sequential monitoring of multiple atomic lines
    Resano, M.
    Rello, L.
    Florez, M.
    Belarra, M. A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 321 - 328
  • [26] Investigation of different chemical modifiers based on the Pd/Mg mixture for the determination of sulfur in shale oil by high-resolution continuum source graphite furnace molecular absorption spectrometry
    dos Passos, A. S.
    Dessuy, M. B.
    Nakadi, F., V
    de Andrade, J. B.
    Vale, M. G. R.
    TALANTA, 2019, 204 : 206 - 212
  • [27] Application of Disposable Pipette Extraction for Determination of Yb by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Using Lanthanum as a Chemical Modifier
    Betiolo, Diogo M.
    Cadorim, Heloisa R.
    Carasek, Eduardo
    Maranhao, Tatiane A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2023, 34 (08) : 1087 - 1099
  • [28] Determination of silicon and aluminum in silicon carbide nanocrystals by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Dravecz, Gabriella
    Bencs, Laszlo
    Beke, David
    Gali, Adam
    TALANTA, 2016, 147 : 271 - 275
  • [29] Sequential determination of cadmium and lead in organic pharmaceutical formulations using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Aleluia, Augusto C. M.
    de Santana, Fernanda A.
    Brandao, Geovani C.
    Ferreira, Sergio L. C.
    MICROCHEMICAL JOURNAL, 2017, 130 : 157 - 161
  • [30] Determination of Mercury in Istanbul Airborne Particles Using Solid Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Baysal, Asli
    Akman, Suleyman
    ANALYTICAL LETTERS, 2016, 49 (12) : 1896 - 1902