Real-time cardiac MRI using an undersampled spiral k-space trajectory and a reconstruction based on a variational network

被引:6
|
作者
Kleineisel, Jonas [1 ]
Heidenreich, Julius F. [1 ]
Eirich, Philipp [1 ,2 ]
Petri, Nils [3 ]
Koestler, Herbert [1 ]
Petritsch, Bernhard [1 ]
Bley, Thorsten A. [1 ]
Wech, Tobias [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacherstr 6, D-97080 Wurzburg, Germany
[2] Univ Hosp Wurzburg, Comprehens Heart Failure Ctr, Wurzburg, Germany
[3] Univ Hosp Wurzburg, Dept Internal Med 1, Wurzburg, Germany
关键词
cardiac imaging; convolutional neural network; heart; machine learning; magnetic resonance imaging; variational network; AGREEMENT;
D O I
10.1002/mrm.29357
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Cardiac MRI represents the gold standard to determine myocardial function. However, the current clinical standard protocol, a segmented Cartesian acquisition, is time-consuming and can lead to compromised image quality in the case of arrhythmia or dyspnea. In this article, a machine learning-based reconstruction of undersampled spiral k-space data is presented to enable free breathing real-time cardiac MRI with good image quality and short reconstruction times. Methods Data were acquired in free breathing with a 2D spiral trajectory corrected by the gradient system transfer function. Undersampled data were reconstructed by a variational network (VN), which was specifically adapted to the non-Cartesian sampling pattern. The network was trained with data from 11 subjects. Subsequently, the imaging technique was validated in 14 subjects by quantifying the difference to a segmented reference acquisition, an expert reader study, and by comparing derived volumes and functional parameters with values obtained using the current clinical gold standard. Results The scan time for the entire heart was below 1 min. The VN reconstructed data in about 0.9 s per image, which is considerably shorter than conventional model-based approaches. The VN furthermore performed better than a U-Net and not inferior to a low-rank plus sparse model in terms of achieved image quality. Functional parameters agreed, on average, with reference data. Conclusions The proposed VN method enables real-time cardiac imaging with both high spatial and temporal resolution in free breathing and with short reconstruction time.
引用
收藏
页码:2167 / 2178
页数:12
相关论文
共 50 条
  • [41] Cardiac real-time MRI using a pre-emphasized spiral acquisition based on the gradient system transfer function
    Eirich, Philipp
    Wech, Tobias
    Heidenreich, Julius F.
    Stich, Manuel
    Petri, Nils
    Nordbeck, Peter
    Bley, Thorsten A.
    Koestler, Herbert
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (05) : 2747 - 2760
  • [42] Global k-Space Interpolation for Dynamic MRI Reconstruction Using Masked Image Modeling
    Pan, Jiazhen
    Shit, Suprosanna
    Turgut, Oezguen
    Huang, Wenqi
    Li, Hongwei Bran
    Stolt-Anso, Nil
    Kuestner, Thomas
    Hammernik, Kerstin
    Rueckert, Daniel
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT X, 2023, 14229 : 228 - 238
  • [43] Quiescent-Inflow Single-Shot Magnetic Resonance Angiography Using a Highly Undersampled Radial k-Space Trajectory
    Edelman, R. R.
    Giri, S.
    Dunkle, E.
    Galizia, M.
    Amin, P.
    Koktzoglou, I.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1662 - 1668
  • [44] Real-time MRI of speaking at a resolution of 33 ms: Undersampled radial FLASH with nonlinear inverse reconstruction
    Niebergall, Aaron
    Zhang, Shuo
    Kunay, Esther
    Keydana, Goetz
    Job, Michael
    Uecker, Martin
    Frahm, Jens
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 477 - 485
  • [45] Rapid reconstruction of highly undersampled, non-Cartesian real-time cinek-space data using a perceptual complex neural network (PCNN)
    Shen, Daming
    Ghosh, Sushobhan
    Haji-Valizadeh, Hassan
    Pathrose, Ashitha
    Schiffers, Florian
    Lee, Daniel C.
    Freed, Benjamin H.
    Markl, Michael
    Cossairt, Oliver S.
    Katsaggelos, Aggelos K.
    Kim, Daniel
    [J]. NMR IN BIOMEDICINE, 2021, 34 (01)
  • [46] Real-time cardiac MRI using DSP's
    Morgan, PN
    Iannuzzelli, RJ
    Epstein, FH
    Balaban, RS
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (07) : 649 - 653
  • [47] DLGAN: Undersampled MRI reconstruction using Deep Learning based Generative Adversarial Network
    Noor, Rida
    Wahid, Abdul
    Bazai, Sibghat Ullah
    Khan, Asad
    Fang, Meie
    Syam, M. S.
    Bhatti, Uzair Aslam
    Ghadi, Yazeed Yasin
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 93
  • [48] Comparison of ECG-gated rectilinear vs. real-time radial K-space sampling schemes in cine true-FISP cardiac MRI
    Boll, DT
    Merkle, EM
    Seaman, DM
    Gilkeson, RC
    Larson, AP
    Simonetti, OP
    Duerk, JL
    Lewin, JS
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2004, 6 (04) : 793 - 802
  • [49] Deblurring for spiral real-time MRI using convolutional neural networks
    Lim, Yongwan
    Bliesener, Yannick
    Narayanan, Shrikanth
    Nayak, Krishna S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3438 - 3452
  • [50] Cardiac MR Motion Artefact Correction from K-space Using Deep Learning-Based Reconstruction
    Oksuz, Ilkay
    Clough, James
    Bustin, Aurelien
    Cruz, Gastao
    Prieto, Claudia
    Botnar, Rene
    Rueckert, Daniel
    Schnabel, Julia A.
    King, Andrew P.
    [J]. MACHINE LEARNING FOR MEDICAL IMAGE RECONSTRUCTION, MLMIR 2018, 2018, 11074 : 21 - 29