Real-time cardiac MRI using an undersampled spiral k-space trajectory and a reconstruction based on a variational network

被引:6
|
作者
Kleineisel, Jonas [1 ]
Heidenreich, Julius F. [1 ]
Eirich, Philipp [1 ,2 ]
Petri, Nils [3 ]
Koestler, Herbert [1 ]
Petritsch, Bernhard [1 ]
Bley, Thorsten A. [1 ]
Wech, Tobias [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacherstr 6, D-97080 Wurzburg, Germany
[2] Univ Hosp Wurzburg, Comprehens Heart Failure Ctr, Wurzburg, Germany
[3] Univ Hosp Wurzburg, Dept Internal Med 1, Wurzburg, Germany
关键词
cardiac imaging; convolutional neural network; heart; machine learning; magnetic resonance imaging; variational network; AGREEMENT;
D O I
10.1002/mrm.29357
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Cardiac MRI represents the gold standard to determine myocardial function. However, the current clinical standard protocol, a segmented Cartesian acquisition, is time-consuming and can lead to compromised image quality in the case of arrhythmia or dyspnea. In this article, a machine learning-based reconstruction of undersampled spiral k-space data is presented to enable free breathing real-time cardiac MRI with good image quality and short reconstruction times. Methods Data were acquired in free breathing with a 2D spiral trajectory corrected by the gradient system transfer function. Undersampled data were reconstructed by a variational network (VN), which was specifically adapted to the non-Cartesian sampling pattern. The network was trained with data from 11 subjects. Subsequently, the imaging technique was validated in 14 subjects by quantifying the difference to a segmented reference acquisition, an expert reader study, and by comparing derived volumes and functional parameters with values obtained using the current clinical gold standard. Results The scan time for the entire heart was below 1 min. The VN reconstructed data in about 0.9 s per image, which is considerably shorter than conventional model-based approaches. The VN furthermore performed better than a U-Net and not inferior to a low-rank plus sparse model in terms of achieved image quality. Functional parameters agreed, on average, with reference data. Conclusions The proposed VN method enables real-time cardiac imaging with both high spatial and temporal resolution in free breathing and with short reconstruction time.
引用
收藏
页码:2167 / 2178
页数:12
相关论文
共 50 条
  • [21] Using Motion Correction to Improve Real-Time Cardiac MRI Reconstruction
    Bilgazyev, E.
    Uyanik, I.
    Unan, M.
    Shah, Dipan
    Tsekos, Nikolaos V.
    Leiss, E. L.
    [J]. SIXTH INTERNATIONAL CONFERENCE ON MACHINE VISION (ICMV 2013), 2013, 9067
  • [22] Cardiac MR Segmentation from Undersampled k-space Using Deep Latent Representation Learning
    Schlemper, Jo
    Oktay, Ozan
    Bai, Wenjia
    Castro, Daniel C.
    Duan, Jinming
    Qin, Chen
    Hajnal, Jo V.
    Rueckert, Daniel
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT I, 2018, 11070 : 259 - 267
  • [23] Partial K-Space MRI Reconstruction Using a Modified Homodyne Approach
    Abche, Antoine
    Yaacoub, Fadi
    Karam, Elie
    [J]. SPA 2010: SIGNAL PROCESSING ALGORITHMS, ARCHITECTURES, ARRANGEMENTS, AND APPLICATIONS CONFERENCE PROCEEDINGS, 2010, : 56 - 61
  • [24] Comparison of spiral and radial k-space filling for real-time MR-guidance for catheterization of renal arteries
    Buecker, A
    Hohl, C
    Schaeffter, T
    Vaals, JJ
    Guenther, RW
    [J]. RADIOLOGY, 2001, 221 : 429 - 429
  • [25] Real-time image reconstruction for spiral MRI using fixed-point calculation
    Liao, JR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (07) : 690 - 698
  • [26] Detection and Correction of Cardiac MRI Motion Artefacts During Reconstruction from k-space
    Oksuz, Ilkay
    Clough, James
    Ruijsink, Bram
    Puyol-Anton, Esther
    Bustin, Aurelien
    Cruz, Gastao
    Prieto, Claudia
    Rueckert, Daniel
    King, Andrew P.
    Schnabel, Julia A.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT IV, 2019, 11767 : 695 - 703
  • [27] Bregman Iteration Based Efficient Algorithm for MR Image Reconstruction From Undersampled K-Space Data
    Duan, Jizhong
    Liu, Yu
    Zhang, Liyi
    [J]. IEEE SIGNAL PROCESSING LETTERS, 2013, 20 (08) : 831 - 834
  • [28] Accelerating dynamic MRI by compressed sensing reconstruction from undersampled k-t space with spiral trajectories
    Tolouee, Azar
    Alirezaie, Javad
    Babyn, Paul
    [J]. 2014 Middle East Conference on Biomedical Engineering (MECBME), 2014, : 17 - 20
  • [29] Constrained Higher Degree Total p-variation Minimization for MRI Reconstruction From Undersampled K-space Data
    Jin, Jiaquan
    Du, Hongwei
    Qiu, Bensheng
    Xu, Jinzhang
    [J]. CURRENT MEDICAL IMAGING, 2018, 14 (06) : 995 - 1005
  • [30] Accelerating GRAPPA reconstruction using SoC design for real-time cardiac MRI
    Basit, Abdul
    Inam, Omair
    Omer, Hammad
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 160