Real-time image reconstruction for spiral MRI using fixed-point calculation

被引:10
|
作者
Liao, JR [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Elect Engn, Taichung 402, Taiwan
关键词
fixed-point representations; real-time image reconstruction; spiral magnetic resonance imaging (MRI); two-dimensional (2-D) fast Fourier transform (FFT);
D O I
10.1109/42.875190
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Because spiral magnetic resonance imaging (MRI) is more robust to motion artifacts than echo planar imaging (EPI), spiral imaging method is more suitable in real-time imaging applications where dynamic processes are to be observed, The major hurdle to use spiral imaging method in real-time applications is its slow reconstruction speed. Since spiral trajectories do not sample data on rectilinear grids, raw data must be regridded before inverse fast Fourier transform (FFT), At present, the computational cost for the spiral reconstruction algorithm is still too high and it is not fast enough to achieve the minimum speed requirement of 20 frames/s for real-time imaging applications. In this paper, we propose to replace floating-point calculations with fixed-point calculations in the reconstruction algorithm to remove the computational bottlenecks. To overcome the quantization and round off errors introduced by fixed-paint calculations, we devise a method to find the optimal precision for the fixed-point representation. Adding with a highly efficient vector-radix two-dimensional (2-D) FFT algorithm and modifications to speed up the gridding convolution, we have cut the reconstruction time by 42% and achieved real-time reconstruction at 30 frames/s for 128 X 128 matrices on low-cost PC's.
引用
收藏
页码:690 / 698
页数:9
相关论文
共 50 条
  • [1] FIXED-POINT REAL TIME MRI RECONSTRUCTION USING CONNEX ARRAY
    Tugui, Andrei
    PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2013, 14 (03): : 255 - 258
  • [2] Fixed-Point CPWC Ultrasound Image Reconstruction
    Shi, Ji
    Rakhmatov, Daler
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1282 - 1285
  • [3] A fixed-point iteration scheme for real-time model predictive control
    Graichen, Knut
    AUTOMATICA, 2012, 48 (07) : 1300 - 1305
  • [4] An FPGA Processor for Real-Time, Fixed-Point Refinement of CDVS Keypoints
    Lopez, Giorgio
    Napoli, Ettore
    Meglio, Domenico
    Strollo, Antonio G. M.
    2015 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2015, : 2832 - 2835
  • [5] Fixed-point Sensitivity Maps for Image Reconstruction in Tomography
    Amirulah, Rahman
    Muji, Siti Zarina Mohd
    Jabbar, Mohamad Hairol
    Syaib, M. Fadzli Abdul
    Rahim, Ruzairi Abdul
    Mahmood, Mohd Nasir
    JURNAL TEKNOLOGI, 2015, 73 (06):
  • [6] Real-time Advanced Speech Enhancement using Low-power, Fixed-point Hardware
    Bismor, Dariusz
    Bartnicki, Krzysztof
    2016 SIGNAL PROCESSING: ALGORITHMS, ARCHITECTURES, ARRANGEMENTS, AND APPLICATIONS (SPA), 2016, : 62 - 67
  • [7] Active catheter tracking using parallel MRI and real-time image reconstruction
    Bock, Michael
    Mueller, Sven
    Zuehlsdorff, Sven
    Speier, Peter
    Fink, Christian
    Hallscheidt, Peter
    Umathum, Reiner
    Semmler, Wolfhard
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1454 - 1459
  • [8] Fixed-Point Convolutional Neural Network for Real-Time Video Processing in FPGA
    Solovyev, Roman
    Kustov, Alexander
    Telpukhov, Dmitry
    Rukhlov, Vladimir
    Kalinin, Alexandr
    PROCEEDINGS OF THE 2019 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2019, : 1605 - 1611
  • [9] FIXED-POINT DSP CHIP CAN GENERATE REAL-TIME RANDOM NOISE
    SALIBRICI, B
    EDN, 1993, 38 (09) : 119 - 122
  • [10] REAL-TIME MOTION DETECTION IN SPIRAL MRI USING NAVIGATORS
    SACHS, TS
    MEYER, CH
    HU, BS
    KOHLI, J
    NISHIMURA, DG
    MACOVSKI, A