Quiescent-Inflow Single-Shot Magnetic Resonance Angiography Using a Highly Undersampled Radial k-Space Trajectory

被引:20
|
作者
Edelman, R. R. [1 ,2 ]
Giri, S. [3 ]
Dunkle, E. [1 ]
Galizia, M. [2 ]
Amin, P. [2 ]
Koktzoglou, I. [1 ,4 ]
机构
[1] NorthShore Univ HealthSyst, Evanston, IL 60201 USA
[2] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Siemens Healthcare, Chicago, IL USA
[4] Univ Chicago, Pritzker Sch Med, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
nonenhanced MR angiography; radial k-space trajectory; highly accelerated MRI; quiescent-inflow single-shot; peripheral arterial disease; MR-ANGIOGRAPHY; PHASED-ARRAY; CONTRAST; DISEASE; FAT;
D O I
10.1002/mrm.24596
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeWe hypothesized that high undersampling factors could be used in conjunction with radial quiescent-inflow single-shot magnetic resonance angiography (MRA) to accelerate the data acquisition and enable multislice acquisitions. MethodsSeven subjects were imaged on a 1.5 T MRI system. For multislice quiescent-inflow single-shot MRA, the venous saturation radiofrequency pulse, in-plane saturation radiofrequency pulse, and quiescent interval were applied only once before the first slice. ResultsThe mean (standard deviation) measurements for the intra-arterial signal-to-noise ratio were as follows: Cartesian 1 slice29.3 (5.5); radial 1 slice, 92 views22.3 (3.6); radial 1 slice, 46 views18.5 (2.0); radial 2 slices, 46 views18.3 (3.2); and radial 3 slices, 32 views21.7 (3.9), normalized for pixel size to 15.8. Horizontal striping was present with multislice radial quiescent-inflow single-shot MRA (especially with the three-slice acquisition) due to variable T-1 relaxation between the concurrently acquired slices, but the image quality remained diagnostic. Vascular pathology in patients with peripheral arterial disease was well shown by all techniques. ConclusionVery high undersampling factors in excess of 18 have been demonstrated for nonenhanced MRA using a radial quiescent-inflow single-shot technique, enabling the acquisition of two to three slices per cardiac cycle. Scan time for a complete peripheral MRA could be shortened to 2 min or less. Magn Reson Med 70:1662-1668, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1662 / 1668
页数:7
相关论文
共 50 条
  • [1] Ungated Radial Quiescent-Inflow Single-Shot (UnQISS) Magnetic Resonance Angiography Using Optimized Azimuthal Equidistant Projections
    Edelman, Robert R.
    Giri, Shivraman
    Murphy, Ian G.
    Flanagan, Oisin
    Speier, Peter
    Koktzoglou, Ioannis
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) : 1522 - 1529
  • [2] Quiescent-Interval Single-Shot Magnetic Resonance Angiography
    Saini, Aman
    Wallace, Alex
    Albadawi, Hassan
    Naidu, Sailendra
    Alzubaidi, Sadeer
    Knuttinen, M. Grace
    Panda, Anshuman
    Oklu, Rahmi
    [J]. DIAGNOSTICS, 2018, 8 (04)
  • [3] Comparison of Quiescent Inflow Single-Shot and Native Space for Nonenhanced Peripheral MR Angiography
    Ward, Emily V.
    Galizia, Mauricio S.
    Usman, Asad
    Popescu, Andrada R.
    Dunkle, Eugene
    Edelman, Robert R.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (06) : 1531 - 1538
  • [4] Frequency resolved single-shot MR imaging using stochastic k-space trajectories
    Scheffler, K
    Hennig, T
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (04) : 569 - 576
  • [5] SINGLE-SHOT MAGNETIC-RESONANCE-IMAGING - APPLICATIONS TO ANGIOGRAPHY
    CRAWLEY, AP
    COHEN, MS
    YUCEL, EK
    PONCELET, B
    BRADY, TJ
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1992, 15 (01) : 32 - 42
  • [6] Shell trajectory sampling of k-space in magnetic resonance imaging
    Gumus, Kazim
    Dundar, Mehmet Sait
    Senol, Serkan
    Bilgen, Mehmet
    [J]. JOURNAL OF BIOTECHNOLOGY, 2016, 231 : S104 - S104
  • [7] Single-shot 3D GRASE with cylindrical k-space trajectories
    Ramanna, S.
    Feinberg, D. A.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (04) : 976 - 980
  • [8] A singular K-space model for fast reconstruction of magnetic resonance images from undersampled data
    Luo, Jianhua
    Mou, Zhiying
    Qin, Binjie
    Li, Wanqing
    Ogunbona, Philip
    Robini, Marc C.
    Zhu, Yuemin
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (07) : 1211 - 1225
  • [9] Quiescent-Interval Single-Shot Unenhanced Magnetic Resonance Angiography of Peripheral Vascular Disease: Technical Considerations and Clinical Feasibility
    Edelman, Robert R.
    Sheehan, John J.
    Dunkle, Eugene
    Schindler, Nancy
    Carr, James
    Koktzoglou, Ioannis
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 951 - 958
  • [10] Accuracy of non-contrast quiescent-interval single-shot and quiescent-interval single-shot arterial spin-labelled magnetic resonance angiography in assessment of peripheral arterial disease in a diabetic population
    Lam, Adrienne
    Perchyonok, Yuliya
    Ranatunga, Dinesh
    Lukies, Matthew W.
    Richmond, Danielle
    Hornsey, Emma K.
    McColl, Brenden
    Heidrich, Jason
    Ko, Pei-Heng
    Spelman, Tim
    Chuen, Jason
    Edelman, Robert R.
    Lim, Ruth P.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2020, 64 (01) : 35 - 43