Quiescent-Inflow Single-Shot Magnetic Resonance Angiography Using a Highly Undersampled Radial k-Space Trajectory

被引:20
|
作者
Edelman, R. R. [1 ,2 ]
Giri, S. [3 ]
Dunkle, E. [1 ]
Galizia, M. [2 ]
Amin, P. [2 ]
Koktzoglou, I. [1 ,4 ]
机构
[1] NorthShore Univ HealthSyst, Evanston, IL 60201 USA
[2] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[3] Siemens Healthcare, Chicago, IL USA
[4] Univ Chicago, Pritzker Sch Med, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
nonenhanced MR angiography; radial k-space trajectory; highly accelerated MRI; quiescent-inflow single-shot; peripheral arterial disease; MR-ANGIOGRAPHY; PHASED-ARRAY; CONTRAST; DISEASE; FAT;
D O I
10.1002/mrm.24596
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeWe hypothesized that high undersampling factors could be used in conjunction with radial quiescent-inflow single-shot magnetic resonance angiography (MRA) to accelerate the data acquisition and enable multislice acquisitions. MethodsSeven subjects were imaged on a 1.5 T MRI system. For multislice quiescent-inflow single-shot MRA, the venous saturation radiofrequency pulse, in-plane saturation radiofrequency pulse, and quiescent interval were applied only once before the first slice. ResultsThe mean (standard deviation) measurements for the intra-arterial signal-to-noise ratio were as follows: Cartesian 1 slice29.3 (5.5); radial 1 slice, 92 views22.3 (3.6); radial 1 slice, 46 views18.5 (2.0); radial 2 slices, 46 views18.3 (3.2); and radial 3 slices, 32 views21.7 (3.9), normalized for pixel size to 15.8. Horizontal striping was present with multislice radial quiescent-inflow single-shot MRA (especially with the three-slice acquisition) due to variable T-1 relaxation between the concurrently acquired slices, but the image quality remained diagnostic. Vascular pathology in patients with peripheral arterial disease was well shown by all techniques. ConclusionVery high undersampling factors in excess of 18 have been demonstrated for nonenhanced MRA using a radial quiescent-inflow single-shot technique, enabling the acquisition of two to three slices per cardiac cycle. Scan time for a complete peripheral MRA could be shortened to 2 min or less. Magn Reson Med 70:1662-1668, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1662 / 1668
页数:7
相关论文
共 50 条
  • [31] Adaptive-size dictionary learning using information theoretic criteria for image reconstruction from undersampled k-space data in low field magnetic resonance imaging
    Emmanuel Ahishakiye
    Martin Bastiaan Van Gijzen
    Julius Tumwiine
    Johnes Obungoloch
    [J]. BMC Medical Imaging, 20
  • [32] Adaptive-size dictionary learning using information theoretic criteria for image reconstruction from undersampled k-space data in low field magnetic resonance imaging
    Ahishakiye, Emmanuel
    Van Gijzen, Martin Bastiaan
    Tumwiine, Julius
    Obungoloch, Johnes
    [J]. BMC MEDICAL IMAGING, 2020, 20 (01)
  • [33] Multi-observer comparison study between unenhanced quiescent-interval single-shot magnetic resonance angiography and invasive carbon dioxide angiography in patients with peripheral arterial disease and chronic renal insufficiency
    Arendt, Christophe T.
    Leithner, Doris
    Lenga, Lukas
    Wichmann, Julian L.
    Albrecht, Moritz H.
    Czwikla, Rouben
    Varga-Szemes, Akos
    d'Angelo, Tommaso
    Martins, Simon S.
    Thalhammer, Axel
    Nagel, Eike
    Vogl, Thomas J.
    Gruber-Rouh, Tatjana
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 140 - 146
  • [34] Parallel magnetic resonance imaging with adaptive radius in k-space (PARS):: Constrained image reconstruction using k-space locality in radiofrequency coil encoded data
    Yeh, EN
    McKenzie, CA
    Ohliger, MA
    Sodickson, DK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1383 - 1392
  • [35] Improved 2D time-of-flight angiography using a radial-line k-space acquisition
    Nielsen, HTC
    Olcott, EW
    Nishimura, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 285 - 291
  • [36] Non-water-suppressed short-echo-time magnetic resonance spectroscopic imaging using a concentric ring k-space trajectory
    Emir, Uzay E.
    Burns, Brian
    Chiew, Mark
    Jezzard, Peter
    Thomas, M. Albert
    [J]. NMR IN BIOMEDICINE, 2017, 30 (07)
  • [37] Witnessing nonclassical correlations via a single-shot experiment on an ensemble of spins using nuclear magnetic resonance
    Singh, Amandeep
    Arvind
    Dorai, Kavita
    [J]. PHYSICAL REVIEW A, 2017, 95 (06)
  • [38] Structure-targeting fast magnetic resonance imaging angiography with partial collection of the inverse space (k-space) based on the orientation of the vessel in real space
    Gui, DW
    Tsekos, NV
    [J]. THIRD IEEE SYMPOSIUM ON BIOINFORMATICS AND BIOENGINEERING - BIBE 2003, PROCEEDINGS, 2003, : 122 - 125
  • [39] High acceleration quiescent-interval single shot magnetic resonance angiography at 3T in patients with peripheral artery disease
    Parag Amin
    Maria Carr
    Marie Wasielewski
    Jeremy Collins
    Robert R Edelman
    James Carr
    [J]. Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [40] Dynamic Contrast-Enhanced Magnetic Resonance Angiography of the Thoracic Vessels An Intraindividual Comparison of Different k-Space Acquisition Strategies
    Seng, Katja
    Maderwald, Stefan
    de Greiff, Armin
    Quick, Harald H.
    Laub, Gerhard
    Schmitt, Peter
    Barkhausen, Joerg
    Vogt, Florian M.
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (11) : 708 - 714