Quiescent-Interval Single-Shot Unenhanced Magnetic Resonance Angiography of Peripheral Vascular Disease: Technical Considerations and Clinical Feasibility

被引:140
|
作者
Edelman, Robert R. [1 ]
Sheehan, John J. [1 ]
Dunkle, Eugene [1 ]
Schindler, Nancy [2 ]
Carr, James [3 ]
Koktzoglou, Ioannis [1 ]
机构
[1] NorthShore Univ HealthSyst, Dept Radiol, Evanston, IL 60201 USA
[2] NorthShore Univ HealthSyst, Dept Surg, Evanston, IL 60201 USA
[3] Northwestern Univ, NW Radiol & Feinberg Sch Med, Chicago, IL 60611 USA
关键词
magnetic resonance angiography unenhanced; flow; peripheral vascular disease; steady-state precession; two dimensional; FLIGHT MR-ANGIOGRAPHY; LOWER-EXTREMITIES; ARTERIAL-DISEASE; OCCLUSIVE DISEASE;
D O I
10.1002/mrm.22287
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We performed technical optimization followed by a pilot clinical study of quiescent-interval single-shot MR angiography for peripheral vascular disease. Quiescent-interval single-shot MR angiography acquires data using a modified electrocardiographic (ECG)-triggered, fat suppressed, two-dimensional, balanced steady-state, free precession pulse sequence incorporating slice-selective saturation and a quiescent interval for maximal enhancement of inflowing blood. Following optimization at 1.5 T, a pilot study was performed in patients with peripheral vascular disease, using contrast-enhanced MR angiography as the reference standard. The optimized sequence used a quiescent interval of 228 ms, alpha/2 catalyzation of the steady-state magnetization, and center-to-out partial Fourier acquisition with parallel acceleration factor of 2. Spatial resolution was 2-3mm along the slice direction and 0.7-1mm in-plane before interpolation. Excluding stented arterial segments, the sensitivity, specificity, and positive and negative predictive values of quiescent-interval single-shot MR angiography for arterial narrowing greater than 50% or occlusion were 92.2%, 94.9%, 83.9%, and 97.7%, respectively. Quiescent-interval single-shot MR angiography provided robust depiction of normal peripheral arterial anatomy and peripheral vascular disease in less than 10 min, without the need to tailor the technique for individual patients. Moreover, the technique provides consistent image quality in the pelvic region despite the presence of respiratory and bowel motion. Magn Reson Med 63:951-958, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:951 / 958
页数:8
相关论文
共 50 条
  • [1] Quiescent-Interval Single-Shot Magnetic Resonance Angiography
    Saini, Aman
    Wallace, Alex
    Albadawi, Hassan
    Naidu, Sailendra
    Alzubaidi, Sadeer
    Knuttinen, M. Grace
    Panda, Anshuman
    Oklu, Rahmi
    [J]. DIAGNOSTICS, 2018, 8 (04)
  • [2] Evaluating Peripheral Arterial Disease With Unenhanced Quiescent-Interval Single-Shot MR Angiography at 3 T
    Amin, Parag
    Collins, Jeremy D.
    Koktzoglou, Ioannis
    Molvar, Christopher
    Markl, Michael
    Edelman, Robert R.
    Carr, James C.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) : 886 - 893
  • [3] Accuracy of non-contrast quiescent-interval single-shot and quiescent-interval single-shot arterial spin-labelled magnetic resonance angiography in assessment of peripheral arterial disease in a diabetic population
    Lam, Adrienne
    Perchyonok, Yuliya
    Ranatunga, Dinesh
    Lukies, Matthew W.
    Richmond, Danielle
    Hornsey, Emma K.
    McColl, Brenden
    Heidrich, Jason
    Ko, Pei-Heng
    Spelman, Tim
    Chuen, Jason
    Edelman, Robert R.
    Lim, Ruth P.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2020, 64 (01) : 35 - 43
  • [4] Evaluation of Peripheral Arterial Disease with Nonenhanced Quiescent-Interval Single-Shot MR Angiography
    Hodnett, Philip A.
    Koktzoglou, Ioannis
    Davarpanah, Amir H.
    Scanlon, Timothy G.
    Collins, Jeremy D.
    Sheehan, John J.
    Dunkle, Eugene E.
    Gupta, Navyash
    Carr, James C.
    Edelman, Robert R.
    [J]. RADIOLOGY, 2011, 260 (01) : 282 - 293
  • [5] Multi-observer comparison study between unenhanced quiescent-interval single-shot magnetic resonance angiography and invasive carbon dioxide angiography in patients with peripheral arterial disease and chronic renal insufficiency
    Arendt, Christophe T.
    Leithner, Doris
    Lenga, Lukas
    Wichmann, Julian L.
    Albrecht, Moritz H.
    Czwikla, Rouben
    Varga-Szemes, Akos
    d'Angelo, Tommaso
    Martins, Simon S.
    Thalhammer, Axel
    Nagel, Eike
    Vogl, Thomas J.
    Gruber-Rouh, Tatjana
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 140 - 146
  • [6] Quiescent-Interval Single-Shot Magnetic Resonance Angiography May Outperform Carbon-Dioxide Digital Subtraction Angiography in Chronic Lower Extremity Peripheral Arterial Disease
    Csore, Judit
    Suhai, Ferenc Imre
    Gyano, Marcell
    Pataki, Akos Andras
    Juhasz, Georgina
    Vecsey-Nagy, Milan
    Pal, Daniel
    Fontanini, Daniele Mariastefano
    Berczi, Akos
    Csobay-Novak, Csaba
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (15)
  • [7] High acceleration quiescent-interval single shot magnetic resonance angiography at 3T in patients with peripheral artery disease
    Parag Amin
    Maria Carr
    Marie Wasielewski
    Jeremy Collins
    Robert R Edelman
    James Carr
    [J]. Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [8] Single-Shot Coronary Quiescent-Interval Slice-Selective Magnetic Resonance Angiography Using Compressed Sensing: A Feasibility Study in Patients With Congenital Heart Disease
    Shen, Daming
    Edelman, Robert R.
    Robinson, Joshua D.
    Haji-Valizadeh, Hassan
    Messina, Marci
    Giri, Shivraman
    Koktzoglou, Ioannis
    Rigsby, Cynthia K.
    Kim, Daniel
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (05) : 739 - 746
  • [9] Evaluation of Peripheral Arterial Disease with Nonenhanced Quiescent-Interval Single-Shot MR Angiography (vol 282, pg 614, 2017)
    Hodnett, Philip A.
    Koktzoglou, Ioannis
    Davarpanah, Amir H.
    Scanlon, Timothy G.
    Collins, Jeremy D.
    Sheehan, John J.
    Dunkle, Eugene E.
    Gupta, Navyash
    Carr, James C.
    Edelman, Robert R.
    [J]. RADIOLOGY, 2017, 282 (02) : 614 - 614
  • [10] Nonenhanced MR angiography of the pulmonary arteries using single-shot radial quiescent-interval slice-selective (QISS): a technical feasibility study
    Edelman, Robert R.
    Silvers, Robert I.
    Thakrar, Kiran H.
    Metzl, Mark D.
    Nazari, Jose
    Giri, Shivraman
    Koktzoglou, Ioannis
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19