Experimental assessment of microwave ablation computational modeling with MR thermometry

被引:18
|
作者
Faridi, Pegah [1 ]
Keselman, Paul [2 ]
Fallahi, Hojjatollah [1 ]
Prakash, Punit [1 ]
机构
[1] Kansas State Univ, Mike Wiegers Dept Elect & Comp Engn, Manhattan, KS 66506 USA
[2] Univ Kansas, Hoglund Brain Imaging Ctr, Med Ctr, Kansas City, KS 66160 USA
基金
美国国家卫生研究院;
关键词
computational modeling; microwave ablation; model validation; MR thermometry; MRI-guided interventions; MAGNETIC-RESONANCE THERMOMETRY; VIVO BOVINE LIVER; EX-VIVO; THERMAL ABLATION; DIELECTRIC-PROPERTIES; TEMPERATURE-DEPENDENCE; RABBIT BRAIN; DESIGN; DEVICE; CONDUCTIVITY;
D O I
10.1002/mp.14318
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Computational models are widely used during the design and characterization of microwave ablation (MWA) devices, and have been proposed for pretreatment planning. Our objective was to assess three-dimensional (3D) transient temperature and ablation profiles predicted by MWA computational models with temperature profiles measured experimentally using magnetic resonance (MR) thermometry inex vivobovine liver. Materials and methods We performed MWA inex vivotissue under MR guidance using a custom, 2.45 GHz water-cooled applicator. MR thermometry data were acquired for 2 min prior to heating, during 5-10 min microwave exposures, and for 3 min following heating. Fiber-optic temperature sensors were used to validate the accuracy of MR temperature measurements. A total of 13 ablation experiments were conducted using 30-50 W applied power at the applicator input. MWA computational models were implemented using the finite element method, and incorporated temperature-dependent changes in tissue physical properties. Model-predicted ablation zone extents were compared against MRI-derived Arrhenius thermal damage maps using the Dice similarity coefficient (DSC). Results Prior to heating, the observed standard deviation of MR temperature data was in the range of 0.3-0.7 degrees C. Mean absolute error between MR temperature measurements and fiber-optic temperature probes during heating was in the range of 0.5-2.8 degrees C. The mean DSC between model-predicted ablation zones and MRI-derived Arrhenius thermal damage maps for 13 experimental set-ups was 0.95. When comparing simulated and experimentally (i.e. using MRI) measured temperatures, the mean absolute error (MAE %) relative to maximum temperature change was in the range 5%-8.5%. Conclusion We developed a system for characterizing 3D transient temperature and ablation profiles with MR thermometry during MWA inex vivoliver tissue, and applied the system for experimental validation of MWA computational models.
引用
收藏
页码:3777 / 3788
页数:12
相关论文
共 50 条
  • [31] Theoretical modeling for hepatic microwave ablation
    Prakash, Punit
    Open Biomedical Engineering Journal, 2010, 4 (SPEC. ISSUE 1): : 27 - 38
  • [32] Reducing electromagnetic interference in MR thermometry: A comparison of setup configurations for MR-guided microwave ablations
    Schroeer, Simon
    Duex, Daniel
    Caballero, Josef Joaquin Loening
    Glandorf, Julian
    Gerlach, Thomas
    Horstmann, Dominik
    Belker, Othmar
    Gutt, Moritz
    Wacker, Frank
    Speck, Oliver
    Hensen, Bennet
    Gutberlet, Marcel
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2025, 35 (01): : 59 - 68
  • [33] Experimental assessment on feasibility of computed tomography-based thermometry for radiofrequency ablation on tissue equivalent polyacrylamide phantom
    Tan, Daryl
    Mohamad, Nurul Ashikin
    Wong, Yin How
    Yeong, Chai Hong
    Cheah, Peng Loon
    Sulaiman, Norshazriman
    Abdullah, Basri Johan Jeet
    Fabell, Mohd Kamil
    Lim, Kok Sing
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 36 (01) : 554 - 561
  • [34] Advancing microwave ablation applicators: integrating computational modeling of a graphene-based applicator with machine learning for ablation zone prediction
    Singh, Suyash Kumar
    Yadav, Amar Nath
    JOURNAL OF COMPUTATIONAL ELECTRONICS, 2024, 23 (04) : 832 - 850
  • [35] Computer modeling and in vitro experimental study of water-cooled microwave ablation array
    Chen, Dui-Dui
    Du, Yu-Xin
    Chen, Zu-Bing
    Lang, Liang
    Ye, Zi
    Yang, Qiang
    Shen, Shi-Qiang
    Lei, Zhen-Yu
    Zhang, Si-Qi
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2021, 30 (01) : 12 - 20
  • [36] Image-based computer modeling assessment of microwave ablation for treatment of adrenal tumors
    Sebek, Jan
    Cappiello, Grazia
    Rahmani, George
    Zeinali, Nooshin
    Keating, Muireann
    Fayemiwo, Michael
    Harkin, Jim
    McDaid, Liam
    Gardiner, Bryan
    Sheppard, Declan
    Senanayake, Russell
    Gurnell, Mark
    O'Halloran, Martin
    Dennedy, M. Conall
    Prakash, Punit
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2022, 39 (01) : 1264 - 1275
  • [37] Microwave Ablation of Osteoid Osteomas Using Dynamic MR Imaging for Early Treatment Assessment: Preliminary Experience
    Kostrzewa, Michael
    Diezler, Patricius
    Michaely, Henrik
    Rathmann, Nils
    Attenberger, Ulrike I.
    Schoenberg, Stefan
    Diehl, Steffen J.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (01) : 106 - 111
  • [38] Computational Modeling and Experimental Microwave Processing of JS']JSC-1A Lunar Simulant
    Allan, Shawn
    Braunstein, Jeffrey
    Baranova, Inessa
    Vandervoort, Nicholas
    Fall, Morgana
    Shulman, Holly
    JOURNAL OF AEROSPACE ENGINEERING, 2013, 26 (01) : 143 - 151
  • [39] Assessment of thermal tissue ablation with MR elastography
    Wu, T
    Felmlee, JP
    Greenleaf, JF
    Riederer, SJ
    Ehman, RL
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (01) : 80 - 87
  • [40] A NEW CRITERION FOR MOTION ESTIMATION ASSESSMENT FOR MR-THERMOMETRY APPLICATIONS
    Roujol, S.
    Ries, M.
    Quesson, B.
    Benois-Pineau, J.
    Moonen, C.
    de Senneville, B. Denis
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1241 - 1244