Reducing electromagnetic interference in MR thermometry: A comparison of setup configurations for MR-guided microwave ablations

被引:1
|
作者
Schroeer, Simon [1 ,3 ]
Duex, Daniel [1 ,3 ]
Caballero, Josef Joaquin Loening [1 ,3 ]
Glandorf, Julian [1 ,3 ]
Gerlach, Thomas [2 ,3 ]
Horstmann, Dominik [1 ,3 ]
Belker, Othmar [1 ,3 ]
Gutt, Moritz [1 ,3 ]
Wacker, Frank [1 ,3 ]
Speck, Oliver [2 ,3 ]
Hensen, Bennet [1 ,3 ]
Gutberlet, Marcel [1 ,3 ]
机构
[1] Hannover Med Sch, Carl Neuberg Str 1, D-30625 Hannover, Lower Saxony, Germany
[2] Otto von Guericke Univ, Univ Pl 2, D-39106 Magdeburg, Saxony Anhalt, Germany
[3] Res Campus STIMULATE, Otto Hahn Str 2, D-39106 Magdeburg, Saxony Anhalt, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2025年 / 35卷 / 01期
关键词
MR thermometry; MR-guided microwave ablation; Electromagnetic compatibility; Electromagnetic interfer- ence; Shielding; CANCER; LIVER;
D O I
10.1016/j.zemedi.2024.07.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Resonance (MR) thermometry is used for the monitoring of MR-guided microwave ablations (MWA), and for the intraoperative evaluation of ablation regions. Nevertheless, the accuracy of temperature mapping may be compromised by electromagnetic interference emanating from the microwave (MW) generator. This study evaluated different setups for improving magnetic resonance imaging (MRI) during MWA with a modified MW generator. MWA was performed in 15 gel phantoms comparing three setups: The MW generator was placed outside the MR scanner room, either connected to the MW applicator using a penetration panel with a radiofrequency (RF) filter and a 7 m coaxial cable (Setup 1), or through a waveguide using a 5 m coaxial cable (Setup 2). Setup 3 employed the MW generator within the MR scan room, connected by a 5 m coaxial cable. The coaxial cables in setups 2 and 3 were modified with custom shielding to reduce interference. The setups during ablation (active setup) were compared to a reference setup without the presence of the MW system. Thermometry and thermal dose maps (CEM43 model) were compared for the three configurations. Primary endpoints for assessment were signal-to-noise ratio (SNR), temperature precision, S & oslash;rensen-Dice-Coefficient (DSC), and RF-noise spectra. Setup 3 showed highly significant electromagnetic interference during ablation with a SNR decrease by -60.4%+/- 13.5% (p<0.001) compared to reference imaging. For setup 1 and setup 2 no significant decrease in SNR was measured with differences of -2.9%+/- 9.8% (p=0.6) and -1.5%+/- 12.8% (p=0.8), respectively. SNR differences were significant between active setups 1 and 3 with -51.2%+/- 16.1% (p<0.001) and between active setups 2 and 3 with -59.0%+/- 15.5% (p<0.001) but not significant between active setups 1 and 2 with 19.0%+/- 13.7% (p=0.09). Furthermore, no significant differences were seen in temperature precision or DSCs between all setups, ranging from 0.33 degrees C +/- 0.04 degrees C (Setup 1) to 0.38 degrees C +/- 0.06 degrees C (Setup 3) (p=0.6) and from 87.0%+/- 1.6% (Setup 3) to 88.1%+/- 1.6% (Setup 2) (p=0.58), respectively. Both setups (1 and 2) with the MW generator outside the MR scanner room were beneficial to reduce electromagnetic interference during MWA. Moreover, provided that a shielded cable is utilized in setups 2 and 3, all configurations displayed negligible differences in temperature precision and DSCs, indicating that the location of the MW generator does not significantly impact the accuracy of thermometry during MWA.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 50 条
  • [1] Practical implementation of robust MR-thermometry during clinical MR-guided microwave ablations in the liver at 1.5 T
    Gorny, K. R.
    Favazza, C. P.
    Lu, A.
    Felmlee, J. P.
    Hangiandreou, N. J.
    Browne, J. E.
    Stenzel, W. S.
    Muggli, J. L.
    Anderson, A. G.
    Thompson, S. M.
    Woodrum, D. A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 67 : 91 - 99
  • [2] Monitoring and visualization techniques for MR-guided laser ablations in an open MR system
    Kettenbach, J
    Silverman, SG
    Hata, N
    Kuroda, K
    Saiviroonporn, P
    Zientara, GP
    Morrison, PR
    Hushek, SG
    Black, PM
    Kikinis, R
    Jolesz, FA
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04): : 933 - 943
  • [3] MR-guided microwave ablation for malignancies
    Kurumi, Yoshimasa
    Tani, Tohru
    Naka, Shigeyuki
    Shiomi, Hisanori
    Shimizu, Tomoharu
    Abe, Hajime
    Endo, Yoshihiro
    Morikawa, Shigehiro
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2007, 12 (02) : 85 - 93
  • [4] MR-guided microwave ablation for malignancies
    Yoshimasa Kurumi
    Tohru Tani
    Shigeyuki Naka
    Hisanori Shiomi
    Tomoharu Shimizu
    Hajime Abe
    Yoshihiro Endo
    Shigehiro Morikawa
    International Journal of Clinical Oncology, 2007, 12 : 85 - 93
  • [5] A probabilistic thermal dose model for the estimation of necrosis in MR-guided tumor ablations
    Schroeer, Simon
    Alpers, Julian
    Gutberlet, Marcel
    Bruesch, Inga
    Rumpel, Regina
    Wacker, Frank
    Hensen, Bennet
    Hansen, Christian
    MEDICAL PHYSICS, 2024, 51 (01) : 239 - 250
  • [6] A system for advanced real-time visualization and monitoring of MR-guided thermal ablations
    Rothgang, Eva
    Gilson, Wesley D.
    Hornegger, Joachim
    Lorenz, Christine H.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [7] MR-guided percutaneous microwave coagulation of small breast tumors
    Ying Ji
    Yaoyao Zhuo
    Ting Li
    Jingge Lian
    Zilin Wang
    Xinyu Guo
    Dexing Kong
    Kangan Li
    Insights into Imaging, 15
  • [8] Improved MR-thermometry during hepatic microwave ablation by correcting for intermittent electromagnetic interference artifacts
    Lu, Aiming
    Woodrum, David A.
    Felmlee, Joel P.
    Favazza, Christopher P.
    Gorny, Krzysztof R.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 71 : 100 - 107
  • [9] MR-guided percutaneous microwave coagulation of small breast tumors
    Ji, Ying
    Zhuo, Yaoyao
    Li, Ting
    Lian, Jingge
    Wang, Zilin
    Guo, Xinyu
    Kong, Dexing
    Li, Kangan
    INSIGHTS INTO IMAGING, 2024, 15 (01)
  • [10] Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases
    Lam, Mie K.
    Huisman, Merel
    Nijenhuis, Robbert J.
    van den Bosch, Maurice A. A. J.
    Viergever, Max A.
    Moonen, Chrit T. W.
    Bartels, Lambertus W.
    JOURNAL OF THERAPEUTIC ULTRASOUND, 2015, 3