Reducing electromagnetic interference in MR thermometry: A comparison of setup configurations for MR-guided microwave ablations

被引:1
|
作者
Schroeer, Simon [1 ,3 ]
Duex, Daniel [1 ,3 ]
Caballero, Josef Joaquin Loening [1 ,3 ]
Glandorf, Julian [1 ,3 ]
Gerlach, Thomas [2 ,3 ]
Horstmann, Dominik [1 ,3 ]
Belker, Othmar [1 ,3 ]
Gutt, Moritz [1 ,3 ]
Wacker, Frank [1 ,3 ]
Speck, Oliver [2 ,3 ]
Hensen, Bennet [1 ,3 ]
Gutberlet, Marcel [1 ,3 ]
机构
[1] Hannover Med Sch, Carl Neuberg Str 1, D-30625 Hannover, Lower Saxony, Germany
[2] Otto von Guericke Univ, Univ Pl 2, D-39106 Magdeburg, Saxony Anhalt, Germany
[3] Res Campus STIMULATE, Otto Hahn Str 2, D-39106 Magdeburg, Saxony Anhalt, Germany
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2025年 / 35卷 / 01期
关键词
MR thermometry; MR-guided microwave ablation; Electromagnetic compatibility; Electromagnetic interfer- ence; Shielding; CANCER; LIVER;
D O I
10.1016/j.zemedi.2024.07.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic Resonance (MR) thermometry is used for the monitoring of MR-guided microwave ablations (MWA), and for the intraoperative evaluation of ablation regions. Nevertheless, the accuracy of temperature mapping may be compromised by electromagnetic interference emanating from the microwave (MW) generator. This study evaluated different setups for improving magnetic resonance imaging (MRI) during MWA with a modified MW generator. MWA was performed in 15 gel phantoms comparing three setups: The MW generator was placed outside the MR scanner room, either connected to the MW applicator using a penetration panel with a radiofrequency (RF) filter and a 7 m coaxial cable (Setup 1), or through a waveguide using a 5 m coaxial cable (Setup 2). Setup 3 employed the MW generator within the MR scan room, connected by a 5 m coaxial cable. The coaxial cables in setups 2 and 3 were modified with custom shielding to reduce interference. The setups during ablation (active setup) were compared to a reference setup without the presence of the MW system. Thermometry and thermal dose maps (CEM43 model) were compared for the three configurations. Primary endpoints for assessment were signal-to-noise ratio (SNR), temperature precision, S & oslash;rensen-Dice-Coefficient (DSC), and RF-noise spectra. Setup 3 showed highly significant electromagnetic interference during ablation with a SNR decrease by -60.4%+/- 13.5% (p<0.001) compared to reference imaging. For setup 1 and setup 2 no significant decrease in SNR was measured with differences of -2.9%+/- 9.8% (p=0.6) and -1.5%+/- 12.8% (p=0.8), respectively. SNR differences were significant between active setups 1 and 3 with -51.2%+/- 16.1% (p<0.001) and between active setups 2 and 3 with -59.0%+/- 15.5% (p<0.001) but not significant between active setups 1 and 2 with 19.0%+/- 13.7% (p=0.09). Furthermore, no significant differences were seen in temperature precision or DSCs between all setups, ranging from 0.33 degrees C +/- 0.04 degrees C (Setup 1) to 0.38 degrees C +/- 0.06 degrees C (Setup 3) (p=0.6) and from 87.0%+/- 1.6% (Setup 3) to 88.1%+/- 1.6% (Setup 2) (p=0.58), respectively. Both setups (1 and 2) with the MW generator outside the MR scanner room were beneficial to reduce electromagnetic interference during MWA. Moreover, provided that a shielded cable is utilized in setups 2 and 3, all configurations displayed negligible differences in temperature precision and DSCs, indicating that the location of the MW generator does not significantly impact the accuracy of thermometry during MWA.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 50 条
  • [21] Adopting MR-guided stereotactic laser ablations for epileptic lesions: initial clinical experience and lessons learned
    Shofty, Ben
    Bergman, Lotem
    Berger, Assaf
    Aizenstein, Orna
    Ben-Valid, Shani
    Gurovich, Dina
    Tankus, Ariel
    Attias, Miryam
    Fahoum, Firas
    Strauss, Ido
    ACTA NEUROCHIRURGICA, 2021, 163 (10) : 2797 - 2803
  • [22] Thermometry during MR-guided focused ultrasound in a preclinical model based on Thiel embalmed tissue
    Karakitsios, Ioannis
    Bobeica, Mariana
    Saliev, Timur
    Rube, Martin
    Melzer, Andreas
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2014, 23 (02) : 120 - 126
  • [23] Initial Experience with MR-Guided Adaptive Radiotherapy for Head and Neck Cancers: Daily Setup and Dosimetric Variability on an MR-Linac
    McDonald, B.
    Vedam, S.
    Yang, J.
    Castillo, P.
    Sobremonte, A.
    Lee, B.
    Wang, J.
    Hughes, N.
    Mohammedsaid, M.
    Fuller, C. D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (05): : 1171 - 1171
  • [24] MR Thermometry Accuracy and Prospective Imaging-Based Patient Selection in MR-Guided Hyperthermia Treatment for Locally Advanced Cervical Cancer
    VilasBoas-Ribeiro, Iva
    Curto, Sergio
    van Rhoon, Gerard C.
    Franckena, Martine
    Paulides, Margarethus M.
    CANCERS, 2021, 13 (14)
  • [25] MR-guided microwave ablation in hepatic tumours: initial results in clinical routine
    Rüdiger Hoffmann
    Hansjörg Rempp
    David-Emanuel Keßler
    Jakob Weiß
    Philippe L. Pereira
    Konstantin Nikolaou
    Stephan Clasen
    European Radiology, 2017, 27 : 1467 - 1476
  • [26] MR-guided microwave ablation in hepatic tumours: initial results in clinical routine
    Hoffmann, Ruediger
    Rempp, Hansjoerg
    Kessler, David-Emanuel
    Weiss, Jakob
    Pereira, Philippe L.
    Nikolaou, Konstantin
    Clasen, Stephan
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1467 - 1476
  • [27] Motion-robust, multi-slice, real-time MR thermometry for MR-guided thermal therapy in abdominal organs
    Kim, Kisoo
    Diederich, Chris
    Narsinh, Kazim
    Ozhinsky, Eugene
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2023, 40 (01)
  • [28] Comparison and evaluation of distortion correction techniques on an MR-guided radiotherapy system
    Gao, Yu
    Yoon, Stephanie
    Savjani, Ricky
    Pham, Jonathan
    Kalbasi, Anusha
    Raldow, Ann
    Low, Daniel A.
    Hu, Peng
    Yang, Yingli
    MEDICAL PHYSICS, 2021, 48 (02) : 691 - 702
  • [29] Comparison of different approaches for automatic plan adaptation in MR-guided radiotherapy
    Tengler, B.
    Hagmueller, M.
    Kuenzel, L. A.
    Zips, D.
    Thorwarth, D.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S576 - S577
  • [30] MR-guided interstitial bipolar RF-thermometry (RFITT): In vitro evaluations and first clinical results
    Mack, MG
    Straub, R
    Desinger, K
    Balzer, JO
    Zangos, S
    Vogl, TJ
    RADIOLOGY, 2000, 217 : 539 - 539