Experimental assessment of microwave ablation computational modeling with MR thermometry

被引:18
|
作者
Faridi, Pegah [1 ]
Keselman, Paul [2 ]
Fallahi, Hojjatollah [1 ]
Prakash, Punit [1 ]
机构
[1] Kansas State Univ, Mike Wiegers Dept Elect & Comp Engn, Manhattan, KS 66506 USA
[2] Univ Kansas, Hoglund Brain Imaging Ctr, Med Ctr, Kansas City, KS 66160 USA
基金
美国国家卫生研究院;
关键词
computational modeling; microwave ablation; model validation; MR thermometry; MRI-guided interventions; MAGNETIC-RESONANCE THERMOMETRY; VIVO BOVINE LIVER; EX-VIVO; THERMAL ABLATION; DIELECTRIC-PROPERTIES; TEMPERATURE-DEPENDENCE; RABBIT BRAIN; DESIGN; DEVICE; CONDUCTIVITY;
D O I
10.1002/mp.14318
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Computational models are widely used during the design and characterization of microwave ablation (MWA) devices, and have been proposed for pretreatment planning. Our objective was to assess three-dimensional (3D) transient temperature and ablation profiles predicted by MWA computational models with temperature profiles measured experimentally using magnetic resonance (MR) thermometry inex vivobovine liver. Materials and methods We performed MWA inex vivotissue under MR guidance using a custom, 2.45 GHz water-cooled applicator. MR thermometry data were acquired for 2 min prior to heating, during 5-10 min microwave exposures, and for 3 min following heating. Fiber-optic temperature sensors were used to validate the accuracy of MR temperature measurements. A total of 13 ablation experiments were conducted using 30-50 W applied power at the applicator input. MWA computational models were implemented using the finite element method, and incorporated temperature-dependent changes in tissue physical properties. Model-predicted ablation zone extents were compared against MRI-derived Arrhenius thermal damage maps using the Dice similarity coefficient (DSC). Results Prior to heating, the observed standard deviation of MR temperature data was in the range of 0.3-0.7 degrees C. Mean absolute error between MR temperature measurements and fiber-optic temperature probes during heating was in the range of 0.5-2.8 degrees C. The mean DSC between model-predicted ablation zones and MRI-derived Arrhenius thermal damage maps for 13 experimental set-ups was 0.95. When comparing simulated and experimentally (i.e. using MRI) measured temperatures, the mean absolute error (MAE %) relative to maximum temperature change was in the range 5%-8.5%. Conclusion We developed a system for characterizing 3D transient temperature and ablation profiles with MR thermometry during MWA inex vivoliver tissue, and applied the system for experimental validation of MWA computational models.
引用
收藏
页码:3777 / 3788
页数:12
相关论文
共 50 条
  • [41] Radiofrequency Ablation, MR Thermometry, and High-Spatial-Resolution MR Parametric Imaging with a Single, Minimally Invasive Device
    Erturk, M. Arcan
    Hegde, Shashank Sathyanarayana
    Bottomley, Paul A.
    RADIOLOGY, 2016, 281 (03) : 927 - 932
  • [42] Thermometry and post-treatment Dimension Analysis of Microwave Ablation on Liver, Kidney and Lung
    Arcaini, Tommaso
    Cesare, Benedetta
    Dorato, Alessandro
    Durante, Elena
    Namakshenas, Pouya
    Ricci, Milena
    Santucci, Domiziana
    Faiella, Eliodoro
    Saccomandi, Paola
    2024 IEEE SENSORS APPLICATIONS SYMPOSIUM, SAS 2024, 2024,
  • [43] Double Slot Antenna for Microwave Thermal Ablation to Treat Bone Tumors: Modeling and Experimental Evaluation
    Trujillo-Romero, Citlalli Jessica
    Leija-Salas, Lorenzo
    Vera-Hernandez, Arturo
    Rico-Martinez, Genaro
    Gutierrez-Martinez, Josefina
    ELECTRONICS, 2021, 10 (07)
  • [44] Experimental evaluation of new thermal inversion approach in correlation microwave thermometry
    Bri, S
    Bellarbi, L
    Habibi, M
    ElKadiri, M
    Mamouni, A
    ELECTRONICS LETTERS, 2000, 36 (05) : 439 - 440
  • [45] Computational Modeling for Assessment of IBD: to be or not to be?
    Vos, Franciscus M.
    Tielbeek, Jeroen A. W.
    Naziroglu, Robiel E.
    Li, Zhang
    Schueffler, Peter
    Mahapatra, Dwarikanath
    Wiebel, Alexander
    Lavini, C.
    Buhmann, Joachim M.
    Hege, Hans-Christian
    Stoker, Jaap
    van Vliet, Lucas J.
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3974 - 3977
  • [46] Symposium on Computational Modeling and Experimental Assessment of Transport Processes in Porous Building Materials
    Zmeskal, Oldrich
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2015 (ICNAAM-2015), 2016, 1738
  • [47] Raman Thermometry for Temperature Assessment of Inorganic Transformations During Microwave Heating
    Jamboretz, John
    Birkel, Christina S.
    JOURNAL OF RAMAN SPECTROSCOPY, 2025, 56 (01) : 49 - 56
  • [48] In vivo image-guided MR thermometry during laser ablation: experience in kidney and liver
    Saccomandi, Paola
    Giraudau, Celine
    Davrieux, Federico
    Quero, Giuseppe
    Schena, Emiliano
    Breschi, Luca
    Di Matteo, Francesco Maria
    Costamagna, Guido
    Marescaux, Jacques
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 515 - 520
  • [49] Realization and Experimental Assessment of Baseball-Bat Microwave Antenna for Low Power Cancer Ablation
    Hassan, Eman G. M., I
    Takruri, Haifa
    Zaki, Amira, I
    IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2020, 4 (02): : 133 - 139
  • [50] Microwave Ablation Monitoring via Microwave Tomography: a Numerical Feasibility Assessment
    Bucci, Ovidio M.
    Cavagnaro, Marta
    Crocco, Lorenzo
    Lopresto, Vanni
    Scapaticci, Rosa
    2016 10TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2016,