Image Quality and Dose Assessment in Inner Ear Computed Tomography Imaging With a Flat Panel-Based System

被引:7
|
作者
Brancaccio, Rosa [1 ,2 ]
Bettuzzi, Matteo [1 ,2 ]
Morigi, Maria Pia [1 ,2 ]
Casali, Franco [1 ,3 ]
Ragazzini, Luca [1 ,2 ]
机构
[1] Univ Bologna, Dept Phys & Astron, Bologna, Italy
[2] Natl Inst Nucl Phys, Bologna, Italy
[3] Enrico Fermi Ctr Study & Res, Rome, Italy
关键词
cone-beam computed tomography; inner ear; 3-dimensional imaging; imaging phantoms; CT; RADIATION; RECONSTRUCTION; MIDDLE;
D O I
10.1097/RCT.0000000000000176
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The temporal bone includes several important structures of the human body, some of which are smaller than 1 mm. The aim of this study is to demonstrate the feasibility of a computed tomography system capable of providing 3-dimensional images of the inner ear with low doses and a spatial resolution adequate for providing the surgeon with good guidance. Methods: A laboratory prototype, based on a CMOS Hamamatsu model C10900D detector, was set up, and several tomographic tests were carried out on 2 dedicated phantoms. Results: The proposed system is able to achieve a 150-mu m spatial resolution (5% of modulation transfer function) with a voxel size of 88 mu m, with an acceptable contrast and an estimated effective dose ranging from 1/20 up to 1/100 of the mean effective dose reported in literature for head computed tomography. Conclusion: The new tomographic system has shown excellent characteristics and proves suitable for the imaging of the inner ear. In particular, this prototype requires very low radiation doses.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [31] Effect of mA Reduction on Image Quality Parameters and Patient Dose in Computed Tomography Imaging
    Saeed, Raed S.
    Brindhaban, Ajit
    Al Khalifah, Khaled H.
    Al Enezi, Ohoud J.
    RADIOLOGIC TECHNOLOGY, 2016, 87 (03) : 271 - 278
  • [32] Optimizing dose and image quality in pediatric computed tomography
    Jones, A.
    Huston, A.
    Falkenstien, P.
    Williams, J.
    Staton, R.
    Hintenlang, D.
    Arreola, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2002 - 2002
  • [33] PATIENT DOSE AND IMAGE QUALITY IN COMPUTED-TOMOGRAPHY
    TREFLER, M
    HAUGHTON, VM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (01) : 25 - 27
  • [34] PATIENT DOSE AND IMAGE QUALITY IN COMPUTED-TOMOGRAPHY
    TREFLER, M
    HAUGHTON, VM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1981, 2 (03) : 269 - 271
  • [35] COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE-IMAGING OF THE INNER-EAR
    JACKLER, RK
    DILLON, WP
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1987, 97 (02) : 183 - 183
  • [36] COMPUTED-TOMOGRAPHY AND MAGNETIC-RESONANCE IMAGING OF THE INNER-EAR
    JACKLER, RK
    DILLON, WP
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1988, 99 (05) : 494 - 504
  • [37] Anatomy of the rabbit inner ear using computed tomography and magnetic resonance imaging
    El-Hameed, Zeinab Said Abd
    El-Shafey, Anwar Abd El-Fattah
    Metwally, Mohamed Attia
    El-Samie, Hesham Abd El-Rahman Abd
    Kassab, A.
    ANATOMIA HISTOLOGIA EMBRYOLOGIA, 2023, 52 (03) : 403 - 410
  • [38] An investigation of the spatial resolution properties of MiniCAT: Flat panel-based volume CT system for head and neck imaging
    Stayman, J.
    Wang, E.
    MEDICAL PHYSICS, 2007, 34 (06) : 2634 - 2634
  • [39] ABDOMEN-PELVIS COMPUTED TOMOGRAPHY PROTOCOL OPTIMIZATION: AN IMAGE QUALITY AND DOSE ASSESSMENT
    Pelegrino Bastos Maues, Nadine Helena
    Fattori Alves, Allan Felipe
    Menegatti Pavan, Ana Luiza
    Ribeiro, Sergio Marrone
    Yamashita, Seizo
    Trindade, Andre Petean
    Mascarenhas, Yvone Maria
    Nicolucci, Patricia
    de Pina, Diana Rodrigues
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (01) : 66 - 72
  • [40] Application of Aortic Computed Tomography Angiography with Low Radiation Dose: Assessment of Image Quality and Radiation Dose
    Liu, Jianhua
    Li, Long
    Zhang, Yan
    Yuan, Qinghai
    Sun, Yong
    2012 IEEE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2012, : 148 - 151