Image Quality and Dose Assessment in Inner Ear Computed Tomography Imaging With a Flat Panel-Based System

被引:7
|
作者
Brancaccio, Rosa [1 ,2 ]
Bettuzzi, Matteo [1 ,2 ]
Morigi, Maria Pia [1 ,2 ]
Casali, Franco [1 ,3 ]
Ragazzini, Luca [1 ,2 ]
机构
[1] Univ Bologna, Dept Phys & Astron, Bologna, Italy
[2] Natl Inst Nucl Phys, Bologna, Italy
[3] Enrico Fermi Ctr Study & Res, Rome, Italy
关键词
cone-beam computed tomography; inner ear; 3-dimensional imaging; imaging phantoms; CT; RADIATION; RECONSTRUCTION; MIDDLE;
D O I
10.1097/RCT.0000000000000176
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The temporal bone includes several important structures of the human body, some of which are smaller than 1 mm. The aim of this study is to demonstrate the feasibility of a computed tomography system capable of providing 3-dimensional images of the inner ear with low doses and a spatial resolution adequate for providing the surgeon with good guidance. Methods: A laboratory prototype, based on a CMOS Hamamatsu model C10900D detector, was set up, and several tomographic tests were carried out on 2 dedicated phantoms. Results: The proposed system is able to achieve a 150-mu m spatial resolution (5% of modulation transfer function) with a voxel size of 88 mu m, with an acceptable contrast and an estimated effective dose ranging from 1/20 up to 1/100 of the mean effective dose reported in literature for head computed tomography. Conclusion: The new tomographic system has shown excellent characteristics and proves suitable for the imaging of the inner ear. In particular, this prototype requires very low radiation doses.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [21] Design and construction of a flat panel-based cone beam volume computed tomography (FPD-CBVCT) imaging system through the adaptation of a commercially available CT system: Work In Progress.
    Conover, D
    Ning, R
    Yu, RF
    Zhong, JM
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 767 - 777
  • [22] Ultra-low-dose computed tomography system with a flat panel detector: assessment of radiation dose reduction and spatial and low contrast resolution
    Nagatani, Yukihiro
    Nitta, Norihisa
    Takahashi, Masashi
    Tezuka, Noriaki
    Nakano, Yasutaka
    Ikeda, Mitsuru
    Kirino, Yuki
    Hashimoto, Keiji
    Otani, Hideji
    Murakami, Yoko
    Murata, Kiyoshi
    RADIATION MEDICINE, 2008, 26 (10): : 627 - 635
  • [23] Ultra-low-dose computed tomography system with a flat panel detector: assessment of radiation dose reduction and spatial and low contrast resolution
    Yukihiro Nagatani
    Norihisa Nitta
    Masashi Takahashi
    Noriaki Tezuka
    Yasutaka Nakano
    Mitsuru Ikeda
    Yuki Kirino
    Keiji Hashimoto
    Hideji Otani
    Yoko Murakami
    Kiyoshi Murata
    Radiation Medicine, 2008, 26 : 627 - 635
  • [24] Assessment of image quality and establishment of local acceptable quality dose for computed tomography based on patient effective diameter
    Hasan, Nada
    Rizk, Chadia
    Marzooq, Fatema
    Khan, Khalid
    AlKhaja, Maryam
    Babikir, Esameldeen
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (04)
  • [25] Radiation dose reduction using a CdZnTe-based computed tomography system: Comparison to flat-panel detectors
    Le, Huy Q.
    Ducote, Justin L.
    Molloi, Sabee
    MEDICAL PHYSICS, 2010, 37 (03) : 1225 - 1236
  • [26] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Geryes, Bouchra Habib
    Calmon, Raphael
    Khraiche, Diala
    Boddaert, Nathalie
    Bonnet, Damien
    Raimondi, Francesca
    EUROPEAN RADIOLOGY, 2016, 26 (07) : 2030 - 2038
  • [27] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Bouchra Habib Geryes
    Raphael Calmon
    Diala Khraiche
    Nathalie Boddaert
    Damien Bonnet
    Francesca Raimondi
    European Radiology, 2016, 26 : 2030 - 2038
  • [28] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684
  • [29] Assessment of image quality in maxillofacial cone-beam computed tomography imaging
    Gamache, Casey
    English, Jeryl D.
    Salas-Lopez, Anna M.
    Rong, John
    Akyalcin, Sercan
    SEMINARS IN ORTHODONTICS, 2015, 21 (04) : 248 - 253
  • [30] Comparison of organ doses and image quality between CT and flat panel XperCT scans in wrist and inner ear examinations
    Damet, J.
    Sans-Merce, M.
    Mieville, F.
    Becker, M.
    Poletti, P. A.
    Verdun, F. R.
    Baechler, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 164 - 168