Image Quality and Dose Assessment in Inner Ear Computed Tomography Imaging With a Flat Panel-Based System

被引:7
|
作者
Brancaccio, Rosa [1 ,2 ]
Bettuzzi, Matteo [1 ,2 ]
Morigi, Maria Pia [1 ,2 ]
Casali, Franco [1 ,3 ]
Ragazzini, Luca [1 ,2 ]
机构
[1] Univ Bologna, Dept Phys & Astron, Bologna, Italy
[2] Natl Inst Nucl Phys, Bologna, Italy
[3] Enrico Fermi Ctr Study & Res, Rome, Italy
关键词
cone-beam computed tomography; inner ear; 3-dimensional imaging; imaging phantoms; CT; RADIATION; RECONSTRUCTION; MIDDLE;
D O I
10.1097/RCT.0000000000000176
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The temporal bone includes several important structures of the human body, some of which are smaller than 1 mm. The aim of this study is to demonstrate the feasibility of a computed tomography system capable of providing 3-dimensional images of the inner ear with low doses and a spatial resolution adequate for providing the surgeon with good guidance. Methods: A laboratory prototype, based on a CMOS Hamamatsu model C10900D detector, was set up, and several tomographic tests were carried out on 2 dedicated phantoms. Results: The proposed system is able to achieve a 150-mu m spatial resolution (5% of modulation transfer function) with a voxel size of 88 mu m, with an acceptable contrast and an estimated effective dose ranging from 1/20 up to 1/100 of the mean effective dose reported in literature for head computed tomography. Conclusion: The new tomographic system has shown excellent characteristics and proves suitable for the imaging of the inner ear. In particular, this prototype requires very low radiation doses.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [41] Evaluation of Homogeneity on Cone Beam Computed Tomography Imaging with Flat Panel Detector
    Sugino, Noriyuki
    JOURNAL OF HARD TISSUE BIOLOGY, 2009, 18 (02) : 101 - 109
  • [42] Bone quality assessment based on cone beam computed tomography imaging
    Hua, Yan
    Nackaerts, Olivia
    Duyck, Joke
    Maes, Frederik
    Jacobs, Reinhilde
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (08) : 767 - 771
  • [43] Small animal imaging using a flat panel detector-based cone beam computed tomography (FPD-CBCT) imaging system
    Conover, DL
    Ning, R
    Yu, Y
    Lu, XH
    Wood, RW
    Reeder, JE
    Johnson, AM
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 307 - 318
  • [44] Inner ear anomaly of three-dimensional computed tomography: Computed tomographic attenuation and image changes
    Isono, M
    Murata, K
    Nakayama, K
    Miyashita, H
    Tanaka, H
    Ishikawa, M
    ACTA OTO-LARYNGOLOGICA, 2000, : 62 - 66
  • [45] Flat-panel CT versus 128-slice CT in temporal bone imaging: Assessment of image quality and radiation dose
    Piergallini, Lorenzo
    Scola, Elisa
    Tuscano, Bruno
    Brambilla, Roberto
    Campoleoni, Mauro
    Raimondi, Gabriella
    Lombardi, Luciano
    Di Berardino, Federica
    Zanetti, Diego
    Sina, Clara
    Triulzi, Fabio
    Conte, Giorgio
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 106 : 106 - 113
  • [46] Evaluation of Radiation Dose and Image Quality for TheVarian Cone Beam Computed Tomography System
    Cheng, H.
    Wu, V.
    Liu, E.
    Kwong, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [47] EVALUATION OF RADIATION DOSE AND IMAGE QUALITY FOR THE VARIAN CONE BEAM COMPUTED TOMOGRAPHY SYSTEM
    Cheng, Harry C. Y.
    Wu, Vincent W. C.
    Liu, Eva S. F.
    Kwong, Dora L. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 291 - 300
  • [48] Imaging of the midpalatal suture in a porcine model: Flat-panel volume computed tomography compared with multislice computed tomography
    Hahn, Wolfram
    Fricke-Zech, Susanne
    Fialka-Fricke, Julia
    Dullin, Christian
    Zapf, Antonia
    Gruber, Rudolf
    Sennhenn-kirchner, Sabine
    Kubein-Meesenburg, Dietmar
    Sadat-Khonsari, Reza
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03): : 443 - 449
  • [49] Impact of Jaw Width On the Megavoltage Computed Tomography Image Quality and Imaging Dose with Helical Tomotherapy
    Chao, M.
    Corry, P.
    MEDICAL PHYSICS, 2012, 39 (06) : 3619 - 3619
  • [50] Cone beam computed tomography for imaging orbital trauma-image quality and radiation dose compared with conventional multislice computed tomography
    Brisco, Jessica
    Fuller, Karen