An investigation of the spatial resolution properties of MiniCAT: Flat panel-based volume CT system for head and neck imaging

被引:0
|
作者
Stayman, J.
Wang, E.
机构
[1] Xoran Technol, Ann Arbor, MI USA
[2] NYU, New York, NY USA
关键词
D O I
10.1118/1.2761693
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Volume computed tomography (VCT) using flat panel detectors has the capability to provide isotropic high spatial resolution, whereas traditional multislice scanners often exhibit decreased spatial resolution in the axial direction. In many clinical applications including temporal bone imaging, reformatted images reviewed for diagnostic purposes and anisotropic resolution can reduce the clinical utility of such views. We present a spatial resolution investigation of the MiniCAT system, a commercially available flat‐panel‐based VCT system made by Xoran Technologies, Inc. and compare spatial resolution with a traditional multislice CT (MSCT) system (Siemens Sensation 16) using standard acquisition protocols. Method and Materials: We investigate the spatial resolution properties of the flat‐panel‐based VCT and traditional MSCT using line pair phantoms and a comparison of scanned human temporal bones. Graded line pair phantoms are scanned in three orientations to provide resolution measures along each axis (X,Y, and Z). The modulation transfer function (MTF) of the MiniCAT system is computed using conventional techniques. Human temporal bone scans are analyzed qualitatively and clarity of various fine detail features is assessed. Results: We find the spatial resolution of the MiniCAT system to be highly isotropic with an MTF that yields 10% contrast at 17 lp/cm. In the qualitative image quality study we find that fine feature details in the temporal bone like the bone overlying the tympanic section of the facial nerve canal are better resolved using the flat‐panel‐based VCT system than in the traditional MSCT. Conclusion: Flat‐panel‐based VCT can provide finer isotropic resolution than traditional MSCT which may give it an advantage in clinical diagnosis — particularly when looking at small details in oblique views as is common in the diagnosis of otologic pathology. Conflict of Interest: Research sponsored by Xoran Technologies, Inc. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2634 / 2634
页数:1
相关论文
共 34 条
  • [1] Volumetry of human molars with flat panel-based volume CT in vitro
    Christian Hannig
    Eva Krieger
    Christian Dullin
    Hans-Albert Merten
    Thomas Attin
    Eckhardt Grabbe
    Gabert Heidrich
    Clinical Oral Investigations, 2006, 10 : 253 - 257
  • [2] Volumetry of human molars with flat panel-based volume CT in vitro
    Hannig, Christian
    Krieger, Eva
    Dullin, Christian
    Merten, Hans-Albert
    Attin, Thomas
    Grabbe, Eckhardt
    Heidrich, Gabert
    CLINICAL ORAL INVESTIGATIONS, 2006, 10 (03) : 253 - 257
  • [3] Experimental flat-panel high-spatial-resolution volume CT of the temporal bone
    Gupta, R
    Bartling, SH
    Basu, SK
    Ross, WR
    Becker, H
    Pfoh, A
    Brady, T
    Curtin, HD
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (08) : 1417 - 1424
  • [4] Flat panel detector-based cone beam volume CT imaging
    Ning, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1370 - 1370
  • [5] xCAT: A mobile, flat-panel volumetric X-ray CT for head and neck imaging
    Zbijewski, Wojciech
    Stayman, J. Webster
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2985 - 2986
  • [6] Image Quality and Dose Assessment in Inner Ear Computed Tomography Imaging With a Flat Panel-Based System
    Brancaccio, Rosa
    Bettuzzi, Matteo
    Morigi, Maria Pia
    Casali, Franco
    Ragazzini, Luca
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (02) : 232 - 239
  • [7] Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation
    Ning, R
    Chen, B
    Yu, RF
    Conover, D
    Tang, XY
    Ning, Y
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 949 - 963
  • [8] Design and construction of a flat panel-based cone beam volume computed tomography (FPD-CBVCT) imaging system through the adaptation of a commercially available CT system: Work In Progress.
    Conover, D
    Ning, R
    Yu, RF
    Zhong, JM
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 767 - 777
  • [9] Flat panel detector-based cone beam volume CT imaging: detector evaluation
    Ning, R
    Tang, XY
    Yu, RF
    Conover, D
    Zhang, DH
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 192 - 203
  • [10] Design and construction of a flat panel-based cone beam computed tomography (FPD-CBCT) imaging system through the adaptation of a commercially available CT system: Recent data
    Conover, D
    Ning, RL
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 610 - 615