Image Quality and Dose Assessment in Inner Ear Computed Tomography Imaging With a Flat Panel-Based System

被引:7
|
作者
Brancaccio, Rosa [1 ,2 ]
Bettuzzi, Matteo [1 ,2 ]
Morigi, Maria Pia [1 ,2 ]
Casali, Franco [1 ,3 ]
Ragazzini, Luca [1 ,2 ]
机构
[1] Univ Bologna, Dept Phys & Astron, Bologna, Italy
[2] Natl Inst Nucl Phys, Bologna, Italy
[3] Enrico Fermi Ctr Study & Res, Rome, Italy
关键词
cone-beam computed tomography; inner ear; 3-dimensional imaging; imaging phantoms; CT; RADIATION; RECONSTRUCTION; MIDDLE;
D O I
10.1097/RCT.0000000000000176
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The temporal bone includes several important structures of the human body, some of which are smaller than 1 mm. The aim of this study is to demonstrate the feasibility of a computed tomography system capable of providing 3-dimensional images of the inner ear with low doses and a spatial resolution adequate for providing the surgeon with good guidance. Methods: A laboratory prototype, based on a CMOS Hamamatsu model C10900D detector, was set up, and several tomographic tests were carried out on 2 dedicated phantoms. Results: The proposed system is able to achieve a 150-mu m spatial resolution (5% of modulation transfer function) with a voxel size of 88 mu m, with an acceptable contrast and an estimated effective dose ranging from 1/20 up to 1/100 of the mean effective dose reported in literature for head computed tomography. Conclusion: The new tomographic system has shown excellent characteristics and proves suitable for the imaging of the inner ear. In particular, this prototype requires very low radiation doses.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [1] Dose and image quality of flat-panel detector volume computed tomography for sinus imaging
    Alspaugh, J.
    Christodoulou, E.
    Goodsitt, M.
    Stayman, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2634 - 2634
  • [2] Comparison of radiation dose and image quality between flat panel computed tomography and multidetector computed tomography in a hybrid CT-angiography suite
    Jones, Aaron K.
    Odisio, Bruno C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 121 - 127
  • [3] C-Arm Cone-Beam Computed Tomography with a flat panel detector for intraoperative renal imaging assessment of image quality
    Burks, Frank N.
    Sebastion, Evelyn L.
    Kim, Leonard H.
    Gonzalez, Jose A.
    Martinez, Alvaro A.
    Kernen, Kenneth M.
    Hafron, Jason M.
    JOURNAL OF UROLOGY, 2008, 179 (04): : 679 - 680
  • [4] Comparing the Image Quality of a Mobile Flat-Panel Computed Tomography and a Multidetector Computed Tomography A Phantom Study
    Neubauer, Jakob
    Voigt, Johannes M.
    Lang, Hannah
    Scheuer, Carsten
    Goerke, Sebastian M.
    Langer, Mathias
    Fiebich, Martin
    Kotter, Elmar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (07) : 491 - 497
  • [5] Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Abdelrahman, Mostafa
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [6] Coronary artery imaging with flat panel computed tomography
    Knollmann, FD
    Edic, PM
    Cesmeli, E
    Pfoh, AH
    Yankah, CA
    Felix, R
    RADIOLOGY, 2002, 225 : 538 - 539
  • [7] Design and construction of a flat panel-based cone beam computed tomography (FPD-CBCT) imaging system through the adaptation of a commercially available CT system: Recent data
    Conover, D
    Ning, RL
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 610 - 615
  • [8] Image quality and dose in computed tomography
    Jurik, AG
    Jessen, KA
    Hansen, J
    EUROPEAN RADIOLOGY, 1997, 7 (01) : 77 - 81
  • [9] Image quality and dose in computed tomography
    A. G. Jurik
    K. A. Jessen
    J. Hansen
    European Radiology, 1997, 7 : 77 - 81
  • [10] Computed tomography:: Image and dose assessment
    Valencia-Ortega, F.
    Ruiz-Trejo, C.
    Rodriguez-Villafuerte, M.
    Buenfil, A. E.
    Mora-Hernandez, L. A.
    MEDICAL PHYSICS, 2006, 854 : 57 - +