Femoral sizer design can increase anterior notching during total knee arthroplasty

被引:10
|
作者
Kawahara, Shinya [1 ,2 ]
Mawatari, Taro [3 ]
Iwamoto, Yukihide [2 ]
Banks, Scott A. [1 ]
机构
[1] Univ Florida, Dept Mech Aerosp Engn, 318 MAE A,116250, Gainesville, FL 32611 USA
[2] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[3] Hamanomachi Hosp, Dept Orthopaed Surg, Chuo Ku, 3-3-1 Nagahama, Fukuoka 8108539, Japan
来源
KNEE | 2016年 / 23卷 / 05期
关键词
Total knee arthroplasty (TKA); Femoral anterior notching; Rotation-modified sizing device; Rotation-unmodified sizing device; ROTATIONAL ALIGNMENT; SUPRACONDYLAR FRACTURE; PATELLOFEMORAL CONTACT; DISTAL FEMUR; COMPONENT; MALROTATION; REPLACEMENT;
D O I
10.1016/j.knee.2015.11.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The anteroposterior (AP) portions of the distal femur are generally resected externally rotated relative to the posterior condylar line (PCL) in non-navigated/measured-resection total knee arthroplasty (TKA). Some femoral sizing devices allow rotational adjustment before sizing (rotation-modified sizing devices), while others do not (rotation-unmodified sizing devices). When rotation-unmodified sizing devices are used, the stylus attached to the sizing device identifies the proximal/anterior flange cut assuming the femoral component is aligned parallel to the PCL. However, if the AP cutting device is externally rotated then unexpected notching of the anterior cortex can occur. Methods: We simulated TKA surgery in 100 Japanese yams osteoarthritic knees using three-dimensional planning software. The femoral component was aligned parallel to the PCL and the AP component position was determined so proximal anterior flange was just touching the anterior cortex. Next, the femoral component was externally rotated parallel to the surgical epicondylar axis (SEA). If the proximal anterior flange penetrated femoral bone, the length and thickness of anterior notching were measured. Results: The proximal anterior flange rested on the anterior cortex or penetrated the femoral bone in all knees. There was a strong positive correlation between PCA and length of anterior notching. Anterior notching more than 10 mm length or one-millimeter thickness occurred in most cases (82.4% and 70.6%, respectively) where the posterior condylar angle (PCA) was more than four degrees. Conclusions: Anterior femoral notching is influenced by the design of the femoral sizing guide and subsequent rotation of cutting blocks, especially in knees with a large PCA. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:890 / 894
页数:5
相关论文
共 50 条
  • [41] Modern total knee arthroplasty designs do not reliably replicate anterior femoral morphology
    Kuo, Alexander W.
    Chen, Darren B.
    Wood, Jil
    MacDessi, Samuel J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (09) : 2808 - 2815
  • [42] Modern total knee arthroplasty designs do not reliably replicate anterior femoral morphology
    Alexander W. Kuo
    Darren B. Chen
    Jil Wood
    Samuel J. MacDessi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 2808 - 2815
  • [43] Which is better? Anterior or posterior referencing for femoral component position in total knee arthroplasty
    Nojiri, Sho
    Hayakawa, Kazue
    Date, Hideki
    Naito, Yasushi
    Sato, Keigo
    Uraya, Yuki
    Fujita, Nobuyuki
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (01)
  • [44] Does flexion of the femoral implant in total knee arthroplasty increase knee flexion: A randomised controlled trial
    Murphy, Michael
    Journeaux, Simon
    Hides, Julie
    Russell, Trevor
    KNEE, 2014, 21 (01): : 257 - 263
  • [45] Total Knee Arthroplasty for Chronic Anterior Knee Dislocation
    Jabalameli, Mahmoud
    Bagherifard, Abolfazl
    Hadi, Hosseinali
    Askari, Alireza
    Ghaffari, Salman
    CLINICAL MEDICINE INSIGHTS-CASE REPORTS, 2018, 11
  • [46] The effects of femoral component design on the patello-femoral joint in a PS total knee arthroplasty
    Pier Francesco Indelli
    Massimiliano Marcucci
    Gennaro Pipino
    Sophie Charlton
    Christian Carulli
    Massimo Innocenti
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 59 - 64
  • [47] FEMORAL COMPONENT LOOSENING IN TOTAL KNEE ARTHROPLASTY
    KING, TV
    SCOTT, RD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1985, (194) : 285 - 290
  • [48] The effects of femoral component design on the patello-femoral joint in a PS total knee arthroplasty
    Indelli, Pier Francesco
    Marcucci, Massimiliano
    Pipino, Gennaro
    Charlton, Sophie
    Carulli, Christian
    Innocenti, Massimo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2014, 134 (01) : 59 - 64
  • [49] "Boot Sign" of Anterior Femoral Condylar Resectional Shape during Total Knee Arthroplasty Is More Frequent in Asian Patients
    Kim, Seong Hwan
    Park, Yong-Beom
    Baek, Suk Ho
    Lee, Jeuk
    Lee, Han-Jun
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (12):
  • [50] Prophylactic intramedullary femoral rodding during total knee arthroplasty with simultaneous femoral plate removal
    Ries, MD
    JOURNAL OF ARTHROPLASTY, 1998, 13 (06): : 718 - 721