Femoral sizer design can increase anterior notching during total knee arthroplasty

被引:10
|
作者
Kawahara, Shinya [1 ,2 ]
Mawatari, Taro [3 ]
Iwamoto, Yukihide [2 ]
Banks, Scott A. [1 ]
机构
[1] Univ Florida, Dept Mech Aerosp Engn, 318 MAE A,116250, Gainesville, FL 32611 USA
[2] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[3] Hamanomachi Hosp, Dept Orthopaed Surg, Chuo Ku, 3-3-1 Nagahama, Fukuoka 8108539, Japan
来源
KNEE | 2016年 / 23卷 / 05期
关键词
Total knee arthroplasty (TKA); Femoral anterior notching; Rotation-modified sizing device; Rotation-unmodified sizing device; ROTATIONAL ALIGNMENT; SUPRACONDYLAR FRACTURE; PATELLOFEMORAL CONTACT; DISTAL FEMUR; COMPONENT; MALROTATION; REPLACEMENT;
D O I
10.1016/j.knee.2015.11.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The anteroposterior (AP) portions of the distal femur are generally resected externally rotated relative to the posterior condylar line (PCL) in non-navigated/measured-resection total knee arthroplasty (TKA). Some femoral sizing devices allow rotational adjustment before sizing (rotation-modified sizing devices), while others do not (rotation-unmodified sizing devices). When rotation-unmodified sizing devices are used, the stylus attached to the sizing device identifies the proximal/anterior flange cut assuming the femoral component is aligned parallel to the PCL. However, if the AP cutting device is externally rotated then unexpected notching of the anterior cortex can occur. Methods: We simulated TKA surgery in 100 Japanese yams osteoarthritic knees using three-dimensional planning software. The femoral component was aligned parallel to the PCL and the AP component position was determined so proximal anterior flange was just touching the anterior cortex. Next, the femoral component was externally rotated parallel to the surgical epicondylar axis (SEA). If the proximal anterior flange penetrated femoral bone, the length and thickness of anterior notching were measured. Results: The proximal anterior flange rested on the anterior cortex or penetrated the femoral bone in all knees. There was a strong positive correlation between PCA and length of anterior notching. Anterior notching more than 10 mm length or one-millimeter thickness occurred in most cases (82.4% and 70.6%, respectively) where the posterior condylar angle (PCA) was more than four degrees. Conclusions: Anterior femoral notching is influenced by the design of the femoral sizing guide and subsequent rotation of cutting blocks, especially in knees with a large PCA. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:890 / 894
页数:5
相关论文
共 50 条
  • [31] Anterior knee pain after a total knee arthroplasty: What can cause this pain?
    Breugem, Stefanus Jacob Martinus
    Haverkamp, Daniel
    WORLD JOURNAL OF ORTHOPEDICS, 2014, 5 (03): : 163 - 170
  • [32] Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty
    Jae Han Ko
    Chang Dong Han
    Kyoo Ho Shin
    Levis Nguku
    Ick Hwan Yang
    Woo Suk Lee
    Kwang Il Kim
    Kwan Kyu Park
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 2476 - 2482
  • [33] Robotic alignment of femoral cutting mask during total knee arthroplasty
    De Momi, E.
    Cerveri, P.
    Gambaretto, E.
    Marchente, M.
    Effretti, O.
    Barbariga, S.
    Gini, G.
    Ferrigno, G.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2008, 3 (05) : 413 - 419
  • [34] Robotic alignment of femoral cutting mask during total knee arthroplasty
    E. De Momi
    P. Cerveri
    E. Gambaretto
    M. Marchente
    O. Effretti
    S. Barbariga
    G. Gini
    G. Ferrigno
    International Journal of Computer Assisted Radiology and Surgery, 2008, 3 : 413 - 419
  • [35] Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty
    Ko, Jae Han
    Han, Chang Dong
    Shin, Kyoo Ho
    Nguku, Levis
    Yang, Ick Hwan
    Lee, Woo Suk
    Kim, Kwang Il
    Park, Kwan Kyu
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2476 - 2482
  • [36] The variability of intramedullary alignment of the femoral component during total knee arthroplasty
    Mihalko, WM
    Boyle, J
    Clark, LD
    Krackow, KA
    JOURNAL OF ARTHROPLASTY, 2005, 20 (01): : 25 - 28
  • [37] Stem to prevent periprosthetic fracture after notching in total knee arthroplasty
    Wan, Qian
    Zhang, Aobo
    Liu, Yang
    Chen, Hao
    Zhao, Xue
    Han, Qing
    Wang, Jincheng
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (10)
  • [38] Can prosthesis design of total knee arthroplasty affect balance?
    Isyar, Mehmet
    Saral, Ilknur
    Guler, Olcay
    Cakar, Engin
    Mahirogullari, Mahir
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2015, 26 (02): : 72 - 76
  • [39] The anterior surface of the femur as a new landmark for femoral component rotation in total knee arthroplasty
    Simon Talbot
    John Bartlett
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 258 - 262
  • [40] The anterior surface of the femur as a new landmark for femoral component rotation in total knee arthroplasty
    Talbot, Simon
    Bartlett, John
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (03) : 258 - 262