Femoral sizer design can increase anterior notching during total knee arthroplasty

被引:10
|
作者
Kawahara, Shinya [1 ,2 ]
Mawatari, Taro [3 ]
Iwamoto, Yukihide [2 ]
Banks, Scott A. [1 ]
机构
[1] Univ Florida, Dept Mech Aerosp Engn, 318 MAE A,116250, Gainesville, FL 32611 USA
[2] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[3] Hamanomachi Hosp, Dept Orthopaed Surg, Chuo Ku, 3-3-1 Nagahama, Fukuoka 8108539, Japan
来源
KNEE | 2016年 / 23卷 / 05期
关键词
Total knee arthroplasty (TKA); Femoral anterior notching; Rotation-modified sizing device; Rotation-unmodified sizing device; ROTATIONAL ALIGNMENT; SUPRACONDYLAR FRACTURE; PATELLOFEMORAL CONTACT; DISTAL FEMUR; COMPONENT; MALROTATION; REPLACEMENT;
D O I
10.1016/j.knee.2015.11.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The anteroposterior (AP) portions of the distal femur are generally resected externally rotated relative to the posterior condylar line (PCL) in non-navigated/measured-resection total knee arthroplasty (TKA). Some femoral sizing devices allow rotational adjustment before sizing (rotation-modified sizing devices), while others do not (rotation-unmodified sizing devices). When rotation-unmodified sizing devices are used, the stylus attached to the sizing device identifies the proximal/anterior flange cut assuming the femoral component is aligned parallel to the PCL. However, if the AP cutting device is externally rotated then unexpected notching of the anterior cortex can occur. Methods: We simulated TKA surgery in 100 Japanese yams osteoarthritic knees using three-dimensional planning software. The femoral component was aligned parallel to the PCL and the AP component position was determined so proximal anterior flange was just touching the anterior cortex. Next, the femoral component was externally rotated parallel to the surgical epicondylar axis (SEA). If the proximal anterior flange penetrated femoral bone, the length and thickness of anterior notching were measured. Results: The proximal anterior flange rested on the anterior cortex or penetrated the femoral bone in all knees. There was a strong positive correlation between PCA and length of anterior notching. Anterior notching more than 10 mm length or one-millimeter thickness occurred in most cases (82.4% and 70.6%, respectively) where the posterior condylar angle (PCA) was more than four degrees. Conclusions: Anterior femoral notching is influenced by the design of the femoral sizing guide and subsequent rotation of cutting blocks, especially in knees with a large PCA. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:890 / 894
页数:5
相关论文
共 50 条
  • [21] Femoral Anterior Tangent Line of the Osteoarthritic Knee for Determining Rotational Alignment of the Femoral Component in Total Knee Arthroplasty
    Watanabe, Hiroki
    Gejo, Ryuichi
    Matsuda, Yoshikazu
    Tatsumi, Ichiro
    Hirakawa, Kazuo
    Kimura, Tomoatsu
    JOURNAL OF ARTHROPLASTY, 2011, 26 (02): : 268 - 273
  • [22] Anterior femoral notching=3 mm is associated with increased risk for supracondylar periprosthetic femoral fracture after total knee arthroplasty: a systematic review and meta-analysis
    Stamiris, Dimitrios
    Gkekas, Nifon K.
    Asteriadis, Konstantinos
    Stamiris, Stavros
    Anagnostis, Panagiotis
    Poultsides, Lazaros
    Sarris, Ioannis
    Potoupnis, Michael
    Kenanidis, Eustathios
    Tsiridis, Eleftherios
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (03): : 383 - 393
  • [23] Anterior femoral notching ≥ 3 mm is associated with increased risk for supracondylar periprosthetic femoral fracture after total knee arthroplasty: a systematic review and meta-analysis
    Dimitrios Stamiris
    Nifon K. Gkekas
    Konstantinos Asteriadis
    Stavros Stamiris
    Panagiotis Anagnostis
    Lazaros Poultsides
    Ioannis Sarris
    Michael Potoupnis
    Eustathios Kenanidis
    Eleftherios Tsiridis
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 383 - 393
  • [24] Distal femoral fracture during primary total knee arthroplasty
    Delasotta, Lawrence A.
    Orozco, Fabio
    Miller, Adam G.
    Post, Zachary
    Ong, Alvin
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 202 - 204
  • [25] The anterior trochlear line as a reference for femoral component positioning in total knee arthroplasty
    Kazuki Morizane
    Toshiaki Takahashi
    Fumihiko Konishi
    Haruyasu Yamamoto
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 2009 - 2015
  • [26] The anterior trochlear line as a reference for femoral component positioning in total knee arthroplasty
    Morizane, Kazuki
    Takahashi, Toshiaki
    Konishi, Fumihiko
    Yamamoto, Haruyasu
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (12) : 2009 - 2015
  • [27] The femoral sulcus in total knee arthroplasty
    Jean-Yves Jenny
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 415 - 415
  • [28] The femoral sulcus in total knee arthroplasty
    Jenny, Jean-Yves
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (03) : 415 - 415
  • [29] The femoral sulcus in total knee arthroplasty
    Lingaraj, Krishna
    Bartlett, John
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (05) : 499 - 502
  • [30] The femoral sulcus in total knee arthroplasty
    Krishna Lingaraj
    John Bartlett
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 499 - 502