The effects of femoral component design on the patello-femoral joint in a PS total knee arthroplasty

被引:19
|
作者
Indelli, Pier Francesco [1 ,2 ,3 ,4 ,5 ]
Marcucci, Massimiliano [1 ,2 ,4 ,5 ]
Pipino, Gennaro [6 ]
Charlton, Sophie [3 ]
Carulli, Christian [4 ]
Innocenti, Massimo [4 ]
机构
[1] Clin Ortoped Univ Firenze, CESAT, Florence, Italy
[2] Fdn Onlus, Fucecchio, Italy
[3] Stanford Univ, Breyer Ctr Overseas Study, Florence, Italy
[4] Clin Ortoped Univ Firenze, Florence, Italy
[5] CESAT, I-50054 Florence, Italy
[6] Osped Villa Regina, Bologna, Italy
关键词
Total knee arthroplasty; Patella; Anterior knee pain; Femoral component design; Patellar resurfacing; TKA; PATELLAR TRACKING; REPLACEMENT; PROSTHESIS; SURVIVAL; TROCHLEA; TKA;
D O I
10.1007/s00402-013-1877-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Anterior knee pain following TKA performed utilizing the PFC Sigma system still represents a cause of failure. The purpose of this study was to evaluate whether or not a recent change in the femoral design (PFC Sigma PS) had a positive impact on the patello-femoral complication rate. A consecutive series of 100 TKA using the PFC Sigma PS system was followed prospectively for a minimum of 3 years. All patellae were replaced and a standard lateral release was never performed. Radiographic analysis following the Knee Society Score (KSS) included antero-posterior weight-bearing, lateral and bilateral axial radiographs. TKA rotational alignment was recorded at the final follow-up in 30 consecutive knees by performing a CT evaluation. Good to excellent clinical results according to the KSS were achieved in 94 % of the knees. Survival without need of reoperation for any reason was 98 % at 3 years minimum follow-up; two reoperations were done for removal of fibromatous intra-articular tissue ("Clunk syndrome"). There were no revisions for septic or aseptic loosening of the components. The mean ROM improved from 104A degrees preoperatively to 115A degrees (97A degrees aEuro"132A degrees) postoperatively: postoperative flexion was 120A degrees or more in 58 % of the knees. Severe anterior knee pain was present in 9 % of patients. Radiographic evaluation showed 90 knees with a tibio-femoral anatomical axis between 8A degrees and 2A degrees of valgus (+/- 3A degrees from the intraoperative goal). CT evaluation of 30 consecutive knees showed that the femoral component positioning in relationship to the trans-epicondylar axis had only 2.80A degrees of external rotation (+/- 2.10A degrees) with respect to a planned external rotation of 3A degrees. This difference was statistically significant. Although the PFC Sigma PS system provides good and predictable results for tricompartmental arthritis of the knee, anterior mechanism complications still represent a reason for dissatisfaction in a substantial group of patients.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [1] The effects of femoral component design on the patello-femoral joint in a PS total knee arthroplasty
    Pier Francesco Indelli
    Massimiliano Marcucci
    Gennaro Pipino
    Sophie Charlton
    Christian Carulli
    Massimo Innocenti
    Archives of Orthopaedic and Trauma Surgery, 2014, 134 : 59 - 64
  • [2] REPLACEMENT OF THE PATELLO-FEMORAL JOINT WITH THE TOTAL CONDYLAR KNEE ARTHROPLASTY
    RANAWAT, CS
    ROSE, HA
    BRYAN, WJ
    INTERNATIONAL ORTHOPAEDICS, 1984, 8 (01) : 61 - 65
  • [3] The patello-femoral joint in total knee arthroplasty: is the design of the trochlea the critical factor?
    S.K. Kulkarni
    M.A.R. Freeman
    J.C. Poal-Manresa
    J.I. Asencio
    J.J. Rodriguez
    Knee Surgery, Sports Traumatology, Arthroscopy, 2001, 9 : S8 - S12
  • [4] The patello-femoral joint in total knee arthroplasty: is the design of the trochlea the critical factor?
    Kulkarni, SK
    Freeman, MAR
    Poal-Manresa, JC
    Asencio, JI
    Rodriguez, JJ
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2001, 9 (Suppl 1) : S8 - S12
  • [5] Contemporary femoral designs in total knee arthroplasty: effects on the patello-femoral congruence
    Indelli, Pier Francesco
    Marcucci, Massimiliano
    Cariello, Donatella
    Poli, Paolo
    Innocenti, Massimo
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (06) : 1167 - 1173
  • [6] Contemporary femoral designs in total knee arthroplasty: effects on the patello-femoral congruence
    Pier Francesco Indelli
    Massimiliano Marcucci
    Donatella Cariello
    Paolo Poli
    Massimo Innocenti
    International Orthopaedics, 2012, 36 : 1167 - 1173
  • [7] Patello-femoral joint in total knee replacement
    Rhee, S. J.
    Haddad, F. S.
    CURRENT ORTHOPAEDICS, 2008, 22 (02): : 132 - 138
  • [8] Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing
    C. Belvedere
    A. Ensini
    A. Leardini
    V. Dedda
    A. Feliciangeli
    F. Cenni
    A. Timoncini
    P. Barbadoro
    S. Giannini
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 1719 - 1727
  • [9] Tibio-femoral and patello-femoral joint kinematics during navigated total knee arthroplasty with patellar resurfacing
    Belvedere, C.
    Ensini, A.
    Leardini, A.
    Dedda, V.
    Feliciangeli, A.
    Cenni, F.
    Timoncini, A.
    Barbadoro, P.
    Giannini, S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1719 - 1727
  • [10] THE PATELLO-FEMORAL JOINT
    FRENCH, PR
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1959, 41 (04): : 857 - 857