Comparing conventional and computer-assisted surgery baseplate and screw placement in reverse shoulder arthroplasty

被引:19
|
作者
Venne, Gabriel [1 ]
Rasquinha, Brian J. [2 ]
Pichora, David [2 ,3 ,4 ]
Ellis, Randy E. [1 ,2 ,3 ,4 ,5 ]
Bicknell, Ryan [3 ,4 ]
机构
[1] Queens Univ, Dept Biomed & Mol Sci, Kingston, ON, Canada
[2] Queens Univ, Dept Mech & Mat Engn, Kingston, ON, Canada
[3] Queens Univ, Dept Surg, Kingston, ON, Canada
[4] Kingston Gen Hosp, Kingston, ON K7L 2V7, Canada
[5] Queens Univ, Sch Comp, Kingston, ON, Canada
关键词
Computer-assisted surgery; reverse shoulder arthroplasty; GLENOID COMPONENT FIXATION; ACCURACY; NAVIGATION;
D O I
10.1016/j.jse.2014.10.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Preoperative planning and intraoperative navigation technologies have each been shown separately to be beneficial for optimizing screw and baseplate positioning in reverse shoulder arthroplasty (RSA) but to date have not been combined. This study describes development of a system for performing computer-assisted RSA glenoid baseplate and screw placement, including preoperative planning, intraoperative navigation, and postoperative evaluation, and compares this system with a conventional approach. Materials and methods: We used a custom-designed system allowing computed tomography (CT)-based preoperative planning, intraoperative navigation, and postoperative evaluation. Five orthopedic surgeons defined common preoperative plans on 3-dimensional CT reconstructed cadaveric shoulders. Each surgeon performed 3 computer-assisted and 3 conventional simulated procedures. The 3-dimensional CT reconstructed postoperative units were digitally matched to the preoperative model for evaluation of entry points, end points, and angulations of screws and baseplate. Values were used to find accuracy and precision of the 2 groups with respect to the defined placement. Statistical analysis was performed by t tests (alpha = .05). Results: Comparison of the groups revealed no difference in accuracy or precision of screws or baseplate entry points (P >.05). Accuracy and precision were improved with use of navigation for end points and angulations of 3 screws (P <.05). Accuracy of the inferior screw showed a trend of improvement with navigation (P >. 05). Navigated baseplate end point precision was improved (P <. 05), with a trend toward improved accuracy (P >.05). Conclusion: We conclude that CT-based preoperative planning and intraoperative navigation allow improved accuracy and precision for screw placement and precision for baseplate positioning with respect to a predefined placement compared with conventional techniques in RSA. Level of evidence: Basic Science, Surgical Technique. (C) 2015 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1112 / 1119
页数:8
相关论文
共 50 条
  • [21] Revision reverse shoulder arthroplasty for the management of baseplate failure: an analysis of 676 revision reverse shoulder arthroplasty procedures
    Ii, Mitchell P. John
    Mesa, Lazaro
    Simon, Peter
    Frankle, Mark A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2024, 33 (03) : 707 - 714
  • [22] Optimal screw placement for base plate fixation in reverse total shoulder arthroplasty
    DiStefano, James Guido
    Park, Andrew Y.
    Nguyen, Thuc-Quyen D.
    Diederichs, Gerd
    Buckley, Jenni M.
    Montgomery, William H., III
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (03) : 467 - 476
  • [23] No difference in accuracy between pinless and conventional computer-assisted surgery in total knee arthroplasty
    Baier, C.
    Maderbacher, G.
    Springorum, H. R.
    Zeman, F.
    Fitz, W.
    Schaumburger, J.
    Grifka, J.
    Beckmann, J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1819 - 1826
  • [24] Pedicle screw placement in the thoracic spine:a randomized comparison study of computer-assisted navigation and conventional techniques
    武汉
    高中礼
    王金成
    李英普
    夏鹏
    姜睿
    Chinese Journal of Traumatology, 2010, (04)
  • [25] Pedicle screw placement in the thoracic spine: a randomized comparison study of computer-assisted navigation and conventional techniques
    Wu Han
    Gao Zhong-li
    Wang Jin-cheng
    Li Ying-pu
    Xia Peng
    Jiang Rui
    CHINESE JOURNAL OF TRAUMATOLOGY, 2010, 13 (04) : 201 - 205
  • [26] Decreased scapular notching with lateralization and inferior baseplate placement in reverse shoulder arthroplasty with high humeral inclination
    Feeley, Brian T.
    Zhang, Alan L.
    Barry, Jeffery J.
    Shin, Edward
    Ho, Julianne
    Tabaraee, Ehsan
    Ma, C. Benjamin
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2014, 8 (03): : 65 - 71
  • [27] Towards computer-assisted surgery in shoulder joint replacement
    Valstar, ER
    Botha, CP
    van der Glas, M
    Rozing, PM
    van der Helm, FCT
    Post, FH
    Vossepoel, AM
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2002, 56 (5-6) : 326 - 337
  • [28] Accuracy of computer-assisted cup placement in total hip arthroplasty
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 301 - 305
  • [29] Effect of baseplate positioning on fixation of reverse total shoulder arthroplasty
    Zhang, Min
    Junaid, Sarah
    Gregory, Thomas
    Hansen, Ulrich
    Cheng, Cheng-Kung
    CLINICAL BIOMECHANICS, 2019, 62 : 15 - 22
  • [30] Accuracy of reverse shoulder arthroplasty angle according to the size of the baseplate
    Werthel, Jean-David
    Villard, Alexandra
    Kazum, Efi
    Deransart, Pierric
    Ramirez, Oscar
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2023, 32 (02) : 310 - 317