Comparing conventional and computer-assisted surgery baseplate and screw placement in reverse shoulder arthroplasty

被引:19
|
作者
Venne, Gabriel [1 ]
Rasquinha, Brian J. [2 ]
Pichora, David [2 ,3 ,4 ]
Ellis, Randy E. [1 ,2 ,3 ,4 ,5 ]
Bicknell, Ryan [3 ,4 ]
机构
[1] Queens Univ, Dept Biomed & Mol Sci, Kingston, ON, Canada
[2] Queens Univ, Dept Mech & Mat Engn, Kingston, ON, Canada
[3] Queens Univ, Dept Surg, Kingston, ON, Canada
[4] Kingston Gen Hosp, Kingston, ON K7L 2V7, Canada
[5] Queens Univ, Sch Comp, Kingston, ON, Canada
关键词
Computer-assisted surgery; reverse shoulder arthroplasty; GLENOID COMPONENT FIXATION; ACCURACY; NAVIGATION;
D O I
10.1016/j.jse.2014.10.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Preoperative planning and intraoperative navigation technologies have each been shown separately to be beneficial for optimizing screw and baseplate positioning in reverse shoulder arthroplasty (RSA) but to date have not been combined. This study describes development of a system for performing computer-assisted RSA glenoid baseplate and screw placement, including preoperative planning, intraoperative navigation, and postoperative evaluation, and compares this system with a conventional approach. Materials and methods: We used a custom-designed system allowing computed tomography (CT)-based preoperative planning, intraoperative navigation, and postoperative evaluation. Five orthopedic surgeons defined common preoperative plans on 3-dimensional CT reconstructed cadaveric shoulders. Each surgeon performed 3 computer-assisted and 3 conventional simulated procedures. The 3-dimensional CT reconstructed postoperative units were digitally matched to the preoperative model for evaluation of entry points, end points, and angulations of screws and baseplate. Values were used to find accuracy and precision of the 2 groups with respect to the defined placement. Statistical analysis was performed by t tests (alpha = .05). Results: Comparison of the groups revealed no difference in accuracy or precision of screws or baseplate entry points (P >.05). Accuracy and precision were improved with use of navigation for end points and angulations of 3 screws (P <.05). Accuracy of the inferior screw showed a trend of improvement with navigation (P >. 05). Navigated baseplate end point precision was improved (P <. 05), with a trend toward improved accuracy (P >.05). Conclusion: We conclude that CT-based preoperative planning and intraoperative navigation allow improved accuracy and precision for screw placement and precision for baseplate positioning with respect to a predefined placement compared with conventional techniques in RSA. Level of evidence: Basic Science, Surgical Technique. (C) 2015 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1112 / 1119
页数:8
相关论文
共 50 条
  • [41] Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 174 - 179
  • [43] Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy?
    S. Krüger
    P. Y. Zambelli
    P.-F. Leyvraz
    B. M. Jolles
    International Orthopaedics, 2009, 33 : 27 - 33
  • [44] Shoulder replacement surgery: computer-assisted preoperative planning and navigation
    Rodriguez, Jose A.
    Entezari, Vahid
    Iannotti, Joseph P.
    Ricchetti, Eric T.
    CURRENT ORTHOPAEDIC PRACTICE, 2019, 30 (03): : 208 - 214
  • [45] Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy?
    Krueger, S.
    Zambelli, P. Y.
    Leyvraz, P. -F.
    Jolles, B. M.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 27 - 33
  • [46] Use of Computer-Assisted Templates for Placement of Osteotomies in Lateral Gap Arthroplasty
    Lu, Chuan
    He, Dongmei
    Yang, Chi
    Wilson, Julian J.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (01) : 30 - 38
  • [47] Accuracy of an Apparatus for Measuring Glenoid Baseplate Micromotion in Reverse Shoulder Arthroplasty
    Torkan, Lawrence F.
    Bryant, John T.
    Bicknell, Ryan T.
    Ploeg, Heidi-Lynn
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2022, 16 (04):
  • [48] Artificial intelligence- and computer-assisted navigation for shoulder surgery
    Lee, Kang-San
    Jung, Seung Ho
    Kim, Dong-Hyun
    Chung, Seok Won
    Yoon, Jong Pil
    JOURNAL OF ORTHOPAEDIC SURGERY, 2024, 32 (01)
  • [49] A Comparison of Central Screw versus Post for Glenoid Baseplate Fixation in Reverse Shoulder Arthroplasty Using a Lateralized Glenoid Design
    Bercik, Michael J.
    Werner, Brian C.
    Sears, Benjamin W.
    Gobezie, Reuben
    Lederman, Evan
    Denard, Patrick J.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (13)
  • [50] The effect of glenoid bone loss on reverse shoulder arthroplasty baseplate fixation
    Formaini, Nathan T.
    Everding, Nathan G.
    Levy, Jonathan C.
    Santoni, Brandon G.
    Nayak, Aniruddh N.
    Wilson, Cooper
    Cabezas, Andres F.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (11) : E312 - E319