Pedicle screw placement in the thoracic spine:a randomized comparison study of computer-assisted navigation and conventional techniques

被引:0
|
作者
武汉 [1 ]
高中礼 [1 ]
王金成 [1 ]
李英普 [1 ]
夏鹏 [1 ]
姜睿 [1 ]
机构
[1] Deparment of Orthopaedics,China-Japan Union Hospital,Jilin University
关键词
D O I
暂无
中图分类号
R687.3 [骨骼手术];
学科分类号
1002 ; 100210 ;
摘要
Objective:To evaluate the accuracy of computer-assisted pedicle screw installation and its clinical benefit as compared with conventional pedicle screw installation techniques. Methods:Total 176 thoracic pedicle screws placed in 42 thoracic fracture patients were involved in the study randomly,20 patients under conventional fluoroscopic control (84 screws) and 22 patients had screw insertion under three dimensional(3D) computer-assisted navigation(92 screws).The 2 groups were compared for accuracy of screw placement,time for screw insertion by postoperative thin-cut CT scans and statistical analysis by x2 test.The cortical perforations were then graded by 2-mm increments:GradeⅠ(good,no cortical perforation),GradeⅡ(screw outside the pedicle<2 mm),GradeⅢ(screw outside the pedicle>2 mm). Results:In computer assisted group,88(95.65%) were GradeⅠ(good),4(4.35%) were GradeⅡ(<2mm),no GradeⅢ(>2 mm) violations.In conventional group,there were 14 cortical violations(16.67%),70(83.33%) were GradeⅠ(good), 11(13.1%) were GradeⅡ(<2 mm),and 3(3.57%) were GradeⅢ(>2 mm) violations(P<0.001).The number(19.57%) of upper thoracic pedicle screws(T1-T4) inserted under 3D computer-assisted navigation was significantly higher than that(3.57%) by conventional fluoroscopic control(P<0.001). Average screw insertion time in conventional group was(4.56±1.03) min and(2.54±0.63) min in computer assisted group (P<0.001).In the conventional group,one patient had pleura injury and one had a minor dura violation. Conclusions:This study provides further evidence that 3D computer-assisted navigation placement of pedicle screws can increase accuracy,reduce surgical time,and be performed safely and effectively at all levels of the thoracic spine,particularly upper thoracic spine.
引用
收藏
相关论文
共 50 条
  • [1] Pedicle screw placement in the thoracic spine: a randomized comparison study of computer-assisted navigation and conventional techniques
    Wu Han
    Gao Zhong-li
    Wang Jin-cheng
    Li Ying-pu
    Xia Peng
    Jiang Rui
    [J]. CHINESE JOURNAL OF TRAUMATOLOGY, 2010, 13 (04) : 201 - 205
  • [2] Computer-assisted thoracic pedicle screw placement -: An in vitro feasibility study
    Kim, KD
    Johnson, JP
    Bloch, O
    Masciopinto, JE
    [J]. SPINE, 2001, 26 (04) : 360 - 364
  • [3] Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    Amiot, LP
    Lang, K
    Putzier, M
    Zippel, H
    Labelle, H
    [J]. SPINE, 2000, 25 (05) : 606 - 614
  • [4] A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study
    Tao Ma
    Yong-Qing Xu
    Yu-Bin Cheng
    Mu-Yao Jiang
    Xing-Ming Xu
    Le Xie
    Sheng Lu
    [J]. Archives of Orthopaedic and Trauma Surgery, 2012, 132 : 65 - 72
  • [5] A novel computer-assisted drill guide template for thoracic pedicle screw placement: a cadaveric study
    Ma, Tao
    Xu, Yong-Qing
    Cheng, Yu-Bin
    Jiang, Mu-Yao
    Xu, Xing-Ming
    Xie, Le
    Lu, Sheng
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (01) : 65 - 72
  • [6] Accuracy of computer-assisted pedicle screw placement for adolescent idiopathic scoliosis: a comparison between robotics and navigation
    Tsutomu Akazawa
    Yoshiaki Torii
    Jun Ueno
    Tasuku Umehara
    Masahiro Iinuma
    Atsuhiro Yoshida
    Ken Tomochika
    Seiji Ohtori
    Hisateru Niki
    [J]. European Spine Journal, 2023, 32 : 651 - 658
  • [7] Accuracy of computer-assisted pedicle screw placement for adolescent idiopathic scoliosis: a comparison between robotics and navigation
    Akazawa, Tsutomu
    Torii, Yoshiaki
    Ueno, Jun
    Umehara, Tasuku
    Iinuma, Masahiro
    Yoshida, Atsuhiro
    Tomochika, Ken
    Ohtori, Seiji
    Niki, Hisateru
    [J]. EUROPEAN SPINE JOURNAL, 2023, 32 (02) : 651 - 658
  • [8] Clinical accuracy of three-dimensional fluoroscopy-based computer-assisted cervical pedicle screw placement: a retrospective comparative study of conventional versus computer-assisted cervical pedicle screw placement
    Ishikawa, Yoshimoto
    Kanemura, Tokumi
    Yoshida, Go
    Ito, Zenya
    Muramoto, Akio
    Ohno, Shuichiro
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (05) : 606 - 611
  • [9] Computer-assisted fluoroscopic navigation of pedicle screw insertion - An in vivo feasibility study
    Fu, TS
    Chen, LH
    Wong, CB
    Lai, PL
    Tsai, TT
    Niu, CC
    Chen, WJ
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06): : 730 - 735
  • [10] A Spine Robotic-Assisted Navigation System for Pedicle Screw Placement
    Chen, Hsuan-Yu
    Xiao, Xiu-Yun
    Chen, Chih-Wei
    Chou, Hao-Kai
    Sung, Chen-Yu
    Lin, Feng Huei
    Chen, Po-Quang
    Wong, Tze-hong
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (159):