An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode

被引:103
|
作者
Cho, WJ [1 ]
Huang, HJ [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
关键词
D O I
10.1021/ac980004a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for urea determination was developed. By cross-linking urease onto a polyaniline-Nafion composite electrode which sensed the ammonium ion effectively, a very sensitive urea biosensor was formed. The effects of applied potential, pH of buffer solutions, now rate of carrier, and possible interferences on the response of urea biosensor were studied, With the developed urea biosensor, a detection limit as low as 0.5 mu M and a response time as short as 40 s were obtained in an now injection analysis system. A relative standard deviation of 2.2% (n = 15) was obtained for the successive analysis of a 0.03 mM standard urea solution. Applicability of the urea biosensor for urea analysis was demonstrated by the analysis of NIST standard reference material and urine samples.
引用
收藏
页码:3946 / 3951
页数:6
相关论文
共 50 条
  • [31] Amperometric creatinine biosensor based on covalently coimmobilized enzymes onto carboxylated multiwalled carbon nanotubes/polyaniline composite film
    Yadav, Sandeep
    Kumar, Ashok
    Pundir, C. S.
    ANALYTICAL BIOCHEMISTRY, 2011, 419 (02) : 277 - 283
  • [32] Fabrication of Biosensor Based on Polyaniline/Gold Nanorod Composite
    Tamer, Ugur
    Seckin, Ali Ihsan
    Temur, Erhan
    Torul, Hilal
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2011, 2011
  • [33] Polyaniline/Prussian-Blue-Based Amperometric Biosensor for Detection of Uric Acid
    Thakur, Bhawana
    Sawant, Shilpa N.
    CHEMPLUSCHEM, 2013, 78 (02): : 166 - 174
  • [34] Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode
    Rachna Rawal
    Sheetal Chawla
    Tulika Dahiya
    Chandra Shekhar Pundir
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2599 - 2608
  • [35] Amperometric pH Sensor Based on Graphene-Polyaniline Composite
    Sha, Rinky
    Komori, Kikuo
    Badhulika, Sushmee
    IEEE SENSORS JOURNAL, 2017, 17 (16) : 5038 - 5043
  • [36] Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode
    Rawal, Rachna
    Chawla, Sheetal
    Dahiya, Tulika
    Pundir, Chandra Shekhar
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2599 - 2608
  • [37] Urea potentiometric enzymatic biosensor based on charged biopolymers and electrodeposited polyaniline
    Lakard, Boris
    Magnin, Delphine
    Deschaume, Olivier
    Vanlancker, Guilhem
    Glinel, Marine
    Demoustier-Champagne, Sophie
    Nysten, Bernard
    Jonas, Alain M.
    Bertrand, Patrick
    Yunus, Sami
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (10): : 4139 - 4145
  • [38] Amperometric Phenol Biosensor Based on Horseradish Peroxidase Entrapped PVF and PPy Composite Film Coated GC Electrode
    Sulak, Meral Topcu
    Erhan, Elif
    Keskinler, Buelent
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2010, 160 (03) : 856 - 867
  • [39] Amperometric Phenol Biosensor Based on Horseradish Peroxidase Entrapped PVF and PPy Composite Film Coated GC Electrode
    Meral Topcu Sulak
    Elif Erhan
    Bülent Keskinler
    Applied Biochemistry and Biotechnology, 2010, 160 : 856 - 867
  • [40] Electrochemical urea biosensor based on Proteus mirabilis urease immobilized over polyaniline PANi-Glassy carbon electrode
    Atailia, Sara
    Baraket, Abdoullatif
    Rabai, Selma
    Benounis, Messaoud
    Jaffrezic, Nicole
    Araar, Hala
    Nait-Bouda, Abdelyamine
    Boumaza, Abdecharif
    Errachid, Abdelhamid
    Houhamdi, Moussa
    ELECTROANALYSIS, 2023, 35 (09)