An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode

被引:103
|
作者
Cho, WJ [1 ]
Huang, HJ [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
关键词
D O I
10.1021/ac980004a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for urea determination was developed. By cross-linking urease onto a polyaniline-Nafion composite electrode which sensed the ammonium ion effectively, a very sensitive urea biosensor was formed. The effects of applied potential, pH of buffer solutions, now rate of carrier, and possible interferences on the response of urea biosensor were studied, With the developed urea biosensor, a detection limit as low as 0.5 mu M and a response time as short as 40 s were obtained in an now injection analysis system. A relative standard deviation of 2.2% (n = 15) was obtained for the successive analysis of a 0.03 mM standard urea solution. Applicability of the urea biosensor for urea analysis was demonstrated by the analysis of NIST standard reference material and urine samples.
引用
收藏
页码:3946 / 3951
页数:6
相关论文
共 50 条
  • [21] FLOW-INJECTION AMPEROMETRIC DETECTION OF HYDRAZINE BY ELECTROCATALYTIC OXIDATION AT A PERFLUOROSULFONATED IONOMER RUTHENIUM OXIDE PYROCHLORE CHEMICALLY-MODIFIED ELECTRODE
    ZEN, JM
    TANG, JS
    ANALYTICAL CHEMISTRY, 1995, 67 (01) : 208 - 211
  • [22] An amperometric urea biosensor based on covalently immobilized urease on an electrode made of hyperbranched polyester functionalized gold nanoparticles
    Tiwari, Ashutosh
    Aryal, Santosh
    Pilla, Srikanth
    Gong, Shaoqin
    TALANTA, 2009, 78 (4-5) : 1401 - 1407
  • [23] Study on the Amperometric Glucose Biosensor Based on Tin Oxide Electrode
    JungChuan Chou
    ShenKan Hsiung
    JuiHsiang Hsieh
    稀有金属材料与工程, 2006, (S3) : 291 - 294
  • [24] A selective cholesterol biosensor blased on composite film modified electrode for amperometric detection
    Li, Jian-Ping
    Gu, Hai-Ning
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2006, 53 (03) : 575 - 582
  • [25] Amperometric biosensor based on a functionalized gold electrode for the detection of antioxidants
    Ignatov, S
    Shishniashvili, D
    Ge, B
    Scheller, FW
    Lisdat, F
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (03): : 191 - 199
  • [26] Study on the amperometric glucose biosensor based on tin oxide electrode
    Liao, Cheng-Wei
    Chou, Jung-Chuan
    Sun, Tai-Ping
    Hsiung, Shen-Kan
    Hsieh, Jui-Hsiang
    RARE METAL MATERIALS AND ENGINEERING, 2006, 35 : 291 - 294
  • [27] Construction of ferrocene modified conducting polymer based amperometric urea biosensor
    Dervisevic, Muamer
    Dervisevic, Esma
    Senel, Mehmet
    Cevik, Emre
    Yildiz, Huseyin Bekir
    Camurlu, Pinar
    ENZYME AND MICROBIAL TECHNOLOGY, 2017, 102 : 53 - 59
  • [28] Preparation of nanocomposite-based biosensor for amperometric urea determination in urine
    Evli, Sinem
    Kilimci, Ulviye
    Karagoz, Miray
    Uygun, Murat
    Uygun, Deniz Aktas
    MICROCHEMICAL JOURNAL, 2024, 200
  • [29] Amperometric urea biosensor using aminated glassy carbon electrode covered with urease immobilized carbon sheet, based on the electrode oxidation of carbamic acid
    Wang, Xiuyun
    Watanabe, Hiroaki
    Sekioka, Naoyuki
    Hamana, Hiroshi
    Uchiyama, Shunichi
    ELECTROANALYSIS, 2007, 19 (12) : 1300 - 1306
  • [30] Amperometric glucose biosensor based on in situ electropolymerized polyaniline/poly(acrylonitrile-co-acrylic acid) composite film
    Shan, Dan
    Wang, Shanxia
    He, Yuanyuan
    Xue, Huaiguo
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (02): : 213 - 217