An amperometric urea biosensor based on a polyaniline-perfluorosulfonated ionomer composite electrode

被引:103
|
作者
Cho, WJ [1 ]
Huang, HJ [1 ]
机构
[1] Natl Sun Yat Sen Univ, Dept Chem, Kaohsiung 80424, Taiwan
关键词
D O I
10.1021/ac980004a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for urea determination was developed. By cross-linking urease onto a polyaniline-Nafion composite electrode which sensed the ammonium ion effectively, a very sensitive urea biosensor was formed. The effects of applied potential, pH of buffer solutions, now rate of carrier, and possible interferences on the response of urea biosensor were studied, With the developed urea biosensor, a detection limit as low as 0.5 mu M and a response time as short as 40 s were obtained in an now injection analysis system. A relative standard deviation of 2.2% (n = 15) was obtained for the successive analysis of a 0.03 mM standard urea solution. Applicability of the urea biosensor for urea analysis was demonstrated by the analysis of NIST standard reference material and urine samples.
引用
收藏
页码:3946 / 3951
页数:6
相关论文
共 50 条
  • [41] Amperometric Detection of Glucose by Polyaniline-Activated Carbon Composite Carbon Paste Electrode
    Colak, Ozlem
    Arslan, Halit
    Zengin, Huseyin
    Zengin, Gulay
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (08): : 6988 - 6997
  • [42] Amperometric nonenzymatic glucose biosensor based on graphite rod electrode modified by Ni-nanoparticle/polypyrrole composite
    Emir, Gamze
    Dilgin, Yusuf
    Ramanaviciene, Almira
    Ramanavicius, Arunas
    MICROCHEMICAL JOURNAL, 2021, 161
  • [43] Polyaniline/carbon nanofiber and organic charge transfer complex based composite electrode for electroanalytical urea detection
    Das, Gautam
    Yoon, Hyon Hee
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (06)
  • [44] Detection of Urea in Human Blood using Graphene-Based Amperometric Biosensor
    Huang, Yu-Ming
    Lin, Jia-Chuan
    Settu, Kalpana
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (07)
  • [45] A Powder Based Polyaniline Carbon Paste Electrode for Urea Analysis
    Shu, Hun-Chi
    Lu, Shu-Pei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2012, 59 (02) : 226 - 230
  • [46] Construction and application of an amperometric uric acid biosensor based on covalent immobilization of uricase on iron oxide nanoparticles/chitosan-g-polyaniline composite film electrodeposited on Pt electrode
    Devi, Rooma
    Pundir, C. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 608 - 615
  • [47] An amperometric oxalate biosensor based on sorghum oxalate oxidase bound carboxylated multiwalled carbon nanotubes-polyaniline composite film
    Yadav, Sandeep
    Devi, Rooma
    Kumari, Santosh
    Yadav, Santa
    Pundir, C. S.
    JOURNAL OF BIOTECHNOLOGY, 2011, 151 (02) : 212 - 217
  • [48] Synthesis of Kraton/Polyaniline Ionomer Composite Membrane as Cu (II) Ion Selective Membrane Electrode
    Ahamed, Mohd, I
    Shakeel, Nimra
    Anwar, Naushad
    Lutfullah
    Khan, Anish
    CURRENT ANALYTICAL CHEMISTRY, 2021, 17 (05) : 653 - 661
  • [49] Bi-enzyme L-arginine-selective amperometric biosensor based on ammonium-sensing polyaniline-modified electrode
    Stasyuk, Nataliya
    Smutok, Oleh
    Gayda, Galina
    Vus, Bohdan
    Koval'chuk, Yevgen
    Gonchar, Mykhailo
    BIOSENSORS & BIOELECTRONICS, 2012, 37 (01): : 46 - 52
  • [50] An amperometric biosensor for glucose based on a composite electrode of glucose dehydrogenase, carbon nanotubes, and plasma-polymerized thin films
    Muguruma, Hitoshi
    Yoshida, Shunsuke
    Urata, Muneyuki
    Fujisawa, Kohta
    Matsui, Yasunori
    ELECTROCHEMISTRY, 2008, 76 (08) : 545 - 548