Urea potentiometric enzymatic biosensor based on charged biopolymers and electrodeposited polyaniline

被引:80
|
作者
Lakard, Boris [1 ]
Magnin, Delphine [2 ]
Deschaume, Olivier [2 ]
Vanlancker, Guilhem [2 ]
Glinel, Marine [2 ]
Demoustier-Champagne, Sophie [2 ]
Nysten, Bernard [2 ]
Jonas, Alain M. [2 ]
Bertrand, Patrick [2 ]
Yunus, Sami [2 ]
机构
[1] Univ Franche Comte, Inst UTINAM, UMR CNRS 6213, Equipe Mat & Surfaces Struct, F-25030 Besancon, France
[2] Catholic Univ Louvain, Inst Condensed Matter & Nanosci, B-1348 Louvain, Belgium
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 10期
关键词
Urea biosensor; Enzyme immobilization; Conducting polymer; Polyaniline; Polyelectrolyte multilayers; Polysaccharides; NANOPOROUS ALUMINA MEMBRANES; INTEGRATED THERMAL BIOSENSOR; ELECTROINACTIVE POLYPYRROLE; PH; IMMOBILIZATION; SURFACE; SENSOR; FILMS; TRANSDUCER; PENICILLIN;
D O I
10.1016/j.bios.2011.04.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric biosensor based on urease was developed for the quantitative determination of urea concentration in aqueous solutions for biomedical applications. The urease was either physisorbed onto an electrodeposited polyaniline film (PANE), or immobilized on a layer-by-layer film (LbL) assembled over the PANI film, that was obtained by the alternate deposition of charged polysaccharides (carboxymethylpullulan (CMP) and chitosan (CHI)). In the latter case, the urease (Urs) enzyme was either physically adsorbed or covalently grafted to the LbL film using carbodiimide coupling reaction. Potentiometric responses of the enzymatic biosensors were measured as a function of the urea concentration in aqueous solutions (from 10(-6) to 10(-1) mol L-1 urea). Very high sensitivity and short response time were observed for the present biosensor. Moreover, a stability study showed a higher stability over time for the potentiometric response of the sensor with the enzyme-grafted LbL film, testifying for the protective nature of the polysaccharide coating and the interest of covalent grafting. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4139 / 4145
页数:7
相关论文
共 50 条
  • [1] The potentiometric biosensor based on polyaniline semiconductor films
    Karyakin, AA
    Bobrova, OA
    Karyakina, EE
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 1996, 32 (08) : 939 - 942
  • [2] A Urea Potentiometric Biosensor Based on a Thiophene Copolymer
    Lai, Cheng-Yuan
    Foot, Peter J. S.
    Brown, John W.
    Spearman, Peter
    BIOSENSORS-BASEL, 2017, 7 (01):
  • [3] Potentiometric biosensor for urea based on electropolymerized electroinactive polypyrrole
    Komaba, S
    Seyama, M
    Momma, T
    Osaka, T
    ELECTROCHIMICA ACTA, 1997, 42 (03) : 383 - 388
  • [4] Application of original assemblies of polyelectrolytes, urease and electrodeposited polyaniline as sensitive films of potentiometric urea biosensors
    Buron, Cedric C.
    Quinart, Melanie
    Vrlinic, Tjasa
    Yunus, Sami
    Glinel, Karine
    Jonas, Alain M.
    Lakard, Boris
    ELECTROCHIMICA ACTA, 2014, 148 : 53 - 61
  • [5] New polyaniline-based potentiometric biosensor for pesticides detection
    Ivanov, AN
    Evtugyn, GA
    Lukachova, LV
    Karyakina, EE
    Budnikov, HC
    Kiseleva, SG
    Orlov, AV
    Karpacheva, GP
    Karyakin, AA
    IEEE SENSORS JOURNAL, 2003, 3 (03) : 333 - 340
  • [6] Potentiometric biosensor for urea determination in milk
    Trivedi, U. B.
    Lakshminarayana, D.
    Kothari, I. L.
    Patel, N. G.
    Kapse, H. N.
    Makhija, K. K.
    Patel, R. B.
    Panchal, C. J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) : 260 - 266
  • [7] Potentiometric Urea Biosensor Based on a Urease-Immobilized Polypyrrole
    Prissanaroon-Ouajai, Walaiporn
    Sirivat, Anuvat
    Pigram, Paul J.
    Brack, Narelle
    MACROMOLECULAR SYMPOSIA, 2015, 354 (01) : 334 - 339
  • [8] Urea potentiometric biosensor based on urease immobilized on chitosan membranes
    Magalhaes, JMCS
    Machado, AASC
    TALANTA, 1998, 47 (01) : 183 - 191
  • [9] Enzymatic electrochemical biosensor for urea with a polyaniline grafted conducting hydrogel composite modified electrode
    Das, Joyati
    Sarkar, Priyabrata
    RSC ADVANCES, 2016, 6 (95): : 92520 - 92533
  • [10] A NOVEL POTENTIOMETRIC GLUCOSE BIOSENSOR BASED ON POLYANILINE SEMICONDUCTOR-FILMS
    KARYAKINA, EE
    NEFTYAKOVA, LV
    KARYAKIN, AA
    ANALYTICAL LETTERS, 1994, 27 (15) : 2871 - 2882