Urea potentiometric enzymatic biosensor based on charged biopolymers and electrodeposited polyaniline

被引:80
|
作者
Lakard, Boris [1 ]
Magnin, Delphine [2 ]
Deschaume, Olivier [2 ]
Vanlancker, Guilhem [2 ]
Glinel, Marine [2 ]
Demoustier-Champagne, Sophie [2 ]
Nysten, Bernard [2 ]
Jonas, Alain M. [2 ]
Bertrand, Patrick [2 ]
Yunus, Sami [2 ]
机构
[1] Univ Franche Comte, Inst UTINAM, UMR CNRS 6213, Equipe Mat & Surfaces Struct, F-25030 Besancon, France
[2] Catholic Univ Louvain, Inst Condensed Matter & Nanosci, B-1348 Louvain, Belgium
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 10期
关键词
Urea biosensor; Enzyme immobilization; Conducting polymer; Polyaniline; Polyelectrolyte multilayers; Polysaccharides; NANOPOROUS ALUMINA MEMBRANES; INTEGRATED THERMAL BIOSENSOR; ELECTROINACTIVE POLYPYRROLE; PH; IMMOBILIZATION; SURFACE; SENSOR; FILMS; TRANSDUCER; PENICILLIN;
D O I
10.1016/j.bios.2011.04.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric biosensor based on urease was developed for the quantitative determination of urea concentration in aqueous solutions for biomedical applications. The urease was either physisorbed onto an electrodeposited polyaniline film (PANE), or immobilized on a layer-by-layer film (LbL) assembled over the PANI film, that was obtained by the alternate deposition of charged polysaccharides (carboxymethylpullulan (CMP) and chitosan (CHI)). In the latter case, the urease (Urs) enzyme was either physically adsorbed or covalently grafted to the LbL film using carbodiimide coupling reaction. Potentiometric responses of the enzymatic biosensors were measured as a function of the urea concentration in aqueous solutions (from 10(-6) to 10(-1) mol L-1 urea). Very high sensitivity and short response time were observed for the present biosensor. Moreover, a stability study showed a higher stability over time for the potentiometric response of the sensor with the enzyme-grafted LbL film, testifying for the protective nature of the polysaccharide coating and the interest of covalent grafting. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4139 / 4145
页数:7
相关论文
共 50 条
  • [41] A Novel Non-enzymatic Glucose Sensor Based on Ag Nanoparticles Electrodeposited on Polyaniline Films
    Song, Xu Chun
    Wang, Ling
    Yin, Hao Yong
    CURRENT NANOSCIENCE, 2012, 8 (06) : 945 - 948
  • [42] An enzymatic biosensor for hydrogen peroxide based on CeO2 nanostructure electrodeposited on ITO surface
    Yagati, Ajay Kumar
    Lee, Taek
    Min, Junhong
    Choi, Jeong-Woo
    BIOSENSORS & BIOELECTRONICS, 2013, 47 : 385 - 390
  • [43] A BIOSENSOR ARRAY BASED ON POLYANILINE
    CONTRACTOR, AQ
    INAMDAR, P
    LAL, R
    SANGODKAR, H
    SRINIVASA, RS
    SUKEERTHI, S
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 209 - PMSE
  • [44] A biosensor array based on polyaniline
    Sangodkar, H
    Sukeerthi, S
    Srinivasa, RS
    Lal, R
    Contractor, AQ
    ANALYTICAL CHEMISTRY, 1996, 68 (05) : 779 - 783
  • [45] ENZYMATIC-POTENTIOMETRIC DETERMINATION OF UREA IN HUMAN-SERUM
    BERMAN, EM
    YAO, SJ
    WOLFSON, SK
    TOKARSKY, JM
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1978, 5 (01): : 63 - 66
  • [46] The Sensing Analysis of the Potentiometric Enzymatic RuO2 Biosensor Based on FPCB for Dopamine Detection
    Kuo, Po-Yu
    Hsu, Ming-Tai
    Wang, Tai-Hui
    Liao, Chi-Han
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2024, 71 (01) : 790 - 796
  • [47] Design and Fabrication of Enzymatic Potentiometric Biosensor Based on Flexible Printed Circuit Board for Glucose Detection
    Kuo, Po-Yu
    Liao, Chi-Han
    Wang, Tai-Hui
    Hsu, Ming-Tai
    IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2024, 23 (02) : 283 - 290
  • [48] Inhibitive determination of mercury and other metal ions by potentiometric urea biosensor
    Krawczyk, TKV
    Moszczynska, T
    Trojanowicz, M
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12): : 681 - 691
  • [49] A Potentiometric Enzymatic Flexible Dopamine Biosensor With Temperature Compensation Based on the Flexible Printed Circuit Board
    Yang, Po-Hui
    Chang, Ying-Sheng
    Chan, Che-Tsung
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [50] Comparing glucose and urea enzymatic electrochemical and optical biosensors based on polyaniline thin films
    Pedroza Dias Mello, Hugo Jose Nogueira
    Bueno, Paulo Roberto
    Mulato, Marcelo
    ANALYTICAL METHODS, 2020, 12 (34) : 4199 - 4210